A Self-Calibration Method for an Implantable Displacement Sensor

被引:0
|
作者
Hao, Shiying [1 ]
机构
[1] Michigan State Univ, Elect & Comp Sci Dept, E Lansing, MI 48824 USA
关键词
Implantable Displacement Sensor; Self Calibration; Wheatstone Bridge; CMOS; ANTERIOR CRUCIATE LIGAMENT; IN-VIVO; FORCES;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes a hardware implementation of an automatic calibration process for an implantable sensor used for monitoring the postoperative stability of a hip or knee implant. The RL-Wheatstone bridge, which is the essential part of the sensor, is capable of being self calibrated in vivo by adjusting its electronic component values alternatively until it is balanced. This calibration method extends the measurement range of the sensor by separating the small, elastic movement from the gross, unrecoverable movement, which is suitable for long term in-vivo measurements. The subsystem for calibration is realized using 0.35 mu m CMOS (Complementary Metal-Oxide Semiconductor) technology on two 2.8 mm(2) chips, consisting of two voltage-controlled resistors, a +/- 90 degrees phase detector and a preamplifier. The simulated and on-bench measured results validate its feasibility to calibrate the bridge, which will ensure a detectable range of +/- 150 mu m in subsequent micromotion measurement.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Snapshot: A self-calibration protocol for camera sensor networks
    Liu, Xiaotao
    Kulkarni, Purushottam
    Shenoy, Prashant
    Ganesan, Deepak
    2006 3RD INTERNATIONAL CONFERENCE ON BROADBAND COMMUNICATIONS, NETWORKS AND SYSTEMS, VOLS 1-3, 2006, : 852 - +
  • [42] Snapshot: A self-calibration protocol for camera sensor networks
    Liu, Xiaotao
    Kulkarni, Purushottam
    Shenoy, Prashant
    Ganesan, Deepak
    2006 3RD INTERNATIONAL CONFERENCE ON BROADBAND COMMUNICATIONS, NETWORKS AND SYSTEMS, VOLS 1-3, 2006, : 832 - +
  • [43] Nonparametric belief propagation for self-calibration in sensor networks
    Ihler, AT
    Fisher, JW
    Moses, RL
    Willsky, AS
    IPSN '04: THIRD INTERNATIONAL SYMPOSIUM ON INFORMATION PROCESSING IN SENSOR NETWORKS, 2004, : 225 - 233
  • [44] Theoretical results on on-line sensor self-calibration
    Martinelli, Agostino
    Weingarten, Jan
    Siegwart, Roland
    2006 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-12, 2006, : 43 - +
  • [45] Passive Joint Emitter Localization with Sensor Self-Calibration
    Zhang, Guangbin
    Liu, Hengyan
    Dai, Wei
    Huang, Tianyao
    Liu, Yimin
    Wang, Xiqin
    REMOTE SENSING, 2023, 15 (03)
  • [46] Self-calibration of a vision-based sensor network
    Marinakis, Dimitri
    Dudek, Gregory
    IMAGE AND VISION COMPUTING, 2009, 27 (1-2) : 116 - 130
  • [47] Array self-calibration with large sensor position errors
    Flanagan, BP
    Bell, KL
    SIGNAL PROCESSING, 2001, 81 (10) : 2201 - 2214
  • [48] UPGRADE METHODS FOR STRATIFIED SENSOR NETWORK SELF-CALIBRATION
    Larsson, M.
    Flood, G.
    Oskarsson, M.
    Astrom, K.
    2020 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2020, : 4851 - 4855
  • [49] Research on self-calibration method of electric field time-grating angular displacement sensor based on error function phase shift
    Yu, Zhicheng
    Li, Zihao
    Pu, Hongji
    Wu, Changliang
    Zhan, Bingnan
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2024, 32 (18): : 2803 - 2813
  • [50] A self-calibration method for robotic measurement system
    Gong, CH
    Yuan, JX
    Ni, J
    JOURNAL OF MANUFACTURING SCIENCE AND ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (01): : 174 - 181