A Self-Calibration Method for an Implantable Displacement Sensor

被引:0
|
作者
Hao, Shiying [1 ]
机构
[1] Michigan State Univ, Elect & Comp Sci Dept, E Lansing, MI 48824 USA
关键词
Implantable Displacement Sensor; Self Calibration; Wheatstone Bridge; CMOS; ANTERIOR CRUCIATE LIGAMENT; IN-VIVO; FORCES;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes a hardware implementation of an automatic calibration process for an implantable sensor used for monitoring the postoperative stability of a hip or knee implant. The RL-Wheatstone bridge, which is the essential part of the sensor, is capable of being self calibrated in vivo by adjusting its electronic component values alternatively until it is balanced. This calibration method extends the measurement range of the sensor by separating the small, elastic movement from the gross, unrecoverable movement, which is suitable for long term in-vivo measurements. The subsystem for calibration is realized using 0.35 mu m CMOS (Complementary Metal-Oxide Semiconductor) technology on two 2.8 mm(2) chips, consisting of two voltage-controlled resistors, a +/- 90 degrees phase detector and a preamplifier. The simulated and on-bench measured results validate its feasibility to calibrate the bridge, which will ensure a detectable range of +/- 150 mu m in subsequent micromotion measurement.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Principle of self-calibration method and calibration of 2-D displacement sensor
    Lin, Yuchi
    Liu, Zhijun
    Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering, 1999, 35 (03): : 94 - 97
  • [2] A Self-Calibration Method for Angular Displacement Sensor Working in Harsh Environments
    Gou, Li
    Peng, Donglin
    Chen, Xihou
    Wu, Liang
    Tang, Qifu
    IEEE SENSORS JOURNAL, 2019, 19 (08) : 3033 - 3040
  • [3] Online self-calibration system for time grating angular displacement sensor
    Gao, Zhong-Hua
    Chen, Xi-Hou
    Peng, Dong-Lin
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2015, 23 (01): : 93 - 101
  • [4] Optical Displacement Sensor Suitable for Vibration Monitoring with Self-Calibration Feature
    Nagy, Laszlo
    Babkovic, Kalman
    Krkljes, Damir
    SENSOR LETTERS, 2013, 11 (10) : 1867 - 1874
  • [5] A Novel Self-Calibration Method for Acoustic Vector Sensor
    Zhang, Yao
    Fu, Jin
    Li, Guannan
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2018, 2018
  • [6] Self-calibration of sensor networks
    Moses, RL
    Patterson, R
    UNATTENDED GROUND SENSOR TECHNOLOGIES AND APPLICATIONS IV, 2002, 4743 : 108 - 119
  • [7] Design and Simulation of a Self-calibration Based High Precision Angular Displacement Sensor
    Tang, Qifu
    Luo, Jiufei
    Jing, Huan
    Chen, Ping
    2018 INTERNATIONAL CONFERENCE ON SENSING, DIAGNOSTICS, PROGNOSTICS, AND CONTROL (SDPC), 2018, : 187 - 191
  • [8] Multisource Self-Calibration for Sensor Arrays
    Wijnholds, Stefan J.
    van der Veen, Alle-Jan
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2009, 57 (09) : 3512 - 3522
  • [9] Self-Calibration Method of Displacement Sensor in AMB-Rotor System Based on Magnetic Bearing Current Control
    Chen, Yulin
    Du, Lei
    Sun, Qiao
    Bai, Jie
    Li, Haitao
    Shi, Yangyang
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 71 (05) : 5148 - 5156
  • [10] Self-calibration study of the embedded angular displacement sensor based on single probe error phase shift method
    Sun, Shizheng
    Zhang, Junming
    Han, Yu
    Tao, Ping'an
    He, Zeyin
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2022, 43 (12): : 96 - 103