Mitigation of Ferroresonance in Line Commutated HVDC Converter Interconnected with Series Compensated Overhead Line Transmission System

被引:0
|
作者
Rao, Jwala Laxmi Narasimha [1 ]
Bansal, Gaurav [1 ]
Auddy, Soubhik [1 ]
Tulkiewicz, Thomas [2 ]
Ohrstrom, Magnus [2 ]
机构
[1] ABB GISPL, Bengaluru, Karnataka, India
[2] ABB AB, Zurich, Switzerland
关键词
Ferroresonance; Ferroresonance Damping Controller (FDC); High Voltage DC (HVDC) system; Fast Fourier Transformation (FFT);
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Ferroresonance is a non-linear resonance which can typically occur when a saturable magnetizing inductance forms a resonance circuit with a capacitor. An example of such a resonance condition can be a system configuration where an overhead transmission line with series compensation terminates into a HVDC converter transformer. Such a configuration may lead to post fault ferroresonance oscillations. Mitigation of ferroresonance using converter controls is a simple and economically attractive solution when compared to other solutions such as installing additional equipment in the network. This paper proposes a damping controller to mitigate ferroresonance oscillations for a HVDC system.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Analysis of interconnection between HVdc transmission with Capacitor Commutated Converter and AC power transmission system
    Tsubota, S
    Funaki, T
    Matsuura, K
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 2926 - 2931
  • [23] Integration of Offshore Wind Farm Using a Hybrid HVDC Transmission Composed by the PWM Current-Source Converter and Line-Commutated Converter
    Torres-Olguin, Raymundo E.
    Garces, Alejandro
    Molinas, Marta
    Undeland, Tore
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2013, 28 (01) : 125 - 134
  • [24] Topology of bipolar hybrid MMC-HVDC for overhead line transmission
    Zhang J.
    Tian X.
    Yan X.
    Zhang, Jianpo (zhangjianpo@126.com), 1600, Automation of Electric Power Systems Press (41): : 93 - 98and105
  • [25] Integration of Offshore Wind Farm using a Hybrid HVDC Transmission Composed by PWM Current-Source Converter and Line-Commutated Converter
    Torres-Olguin, Raymundo E.
    Garces, Alejandro
    Molinas, Marta
    Underland, Tore
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [26] Energy harvesting from corona discharge on HVdc overhead transmission line
    Gu, Liang
    Ren, Wenfa
    Jiang, Zheng
    He, Juan
    Hu, Xiaoqian
    Tan, Wei
    Chen, Xingang
    ELECTRICAL ENGINEERING, 2025,
  • [27] The Challenges in a Case of Protecting a Series Compensated Transmission Line
    ElMehdi, Abosalah
    Ben-Ashour, Ali
    2021 18TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS & DEVICES (SSD), 2021, : 699 - 704
  • [28] Control Strategy of Active Commutated Converter for HVDC transmission system under Unbalanced Grid
    Xia, Bing
    Yang, Guang
    Liu, Yong
    Kang, Jun
    Xu, Honghua
    2020 23RD INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2020, : 879 - 882
  • [29] NEUTRAL LINE PROTECTION SYSTEM FOR HVDC TRANSMISSION
    KATO, Y
    WATANABE, A
    KONISHI, H
    KAWAI, T
    INOUE, Y
    IROKAWA, H
    IEEE TRANSACTIONS ON POWER DELIVERY, 1986, 1 (03) : 326 - 331
  • [30] On-line Monitoring System for Icing State of Overhead Transmission Line
    Nie, Shiguang
    Qu, Guangyu
    Ye, Haifeng
    Jiang, Xiuchen
    2012 POWER ENGINEERING AND AUTOMATION CONFERENCE (PEAM), 2012, : 506 - 510