Advances in superheated drop (bubble) detector techniques

被引:36
|
作者
dErrico, F
Alberts, WG
Matzke, M
机构
关键词
D O I
10.1093/oxfordjournals.rpd.a031921
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
State-of-the-art neutron dosemeters based on superheated drop (bubble) detectors are described. These are either active systems for area monitoring, which rely on the acoustical recording of drop vaporisations, or passive pen size ones for personal dosimetry, based on optical bubble counting. The technological solutions developed for the construction of robust devices for health physics applications are described with special emphasis on methods adopted to reduce mechanical shock and temperature sensitivity of the detectors. Finally, a review is given of some current research activities. In particular, a new approach to neutron spectrometry is presented which relies on the thermal effects for the definition of the response matrix of the system.
引用
收藏
页码:103 / 108
页数:6
相关论文
共 50 条
  • [31] SUPERHEATED-DROP (BUBBLE) NEUTRON DETECTORS AND THEIR COMPLIANCE WITH ICRP-60
    DERRICO, F
    ALBERTS, WG
    RADIATION PROTECTION DOSIMETRY, 1994, 54 (3-4) : 357 - 360
  • [32] An active drop counting device using condenser microphone for superheated emulsion detector
    Das, Mala
    Arya, A. S.
    Marick, C.
    Kanjilal, D.
    Saha, S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (11):
  • [33] CALIBRATION OF THE SUPERHEATED DROP DETECTOR (SDD) WITH CF-252 NEUTRON SOURCES
    LO, YC
    APFEL, RE
    HEALTH PHYSICS, 1986, 50 : S8 - S8
  • [34] The nucleation parameter for heavy-ion induced bubble nucleation in superheated emulsion detector
    Seth, S.
    Das, M.
    Bhattacharya, S.
    Bhattacharjee, P.
    Saha, S.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [35] Single bubble and drop techniques for characterizing foams and emulsions
    Suja, V. Chandran
    Rodriguez-Hakim, M.
    Tajuelo, J.
    Fuller, G. G.
    ADVANCES IN COLLOID AND INTERFACE SCIENCE, 2020, 286
  • [36] Effect of lead converter on superheated drop detector response to high-energy neutrons
    Sawamura, T
    Kaneko, JH
    Abe, M
    Tamura, M
    Murai, I
    Homma, A
    Fujita, F
    Tsuda, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 29 - 32
  • [37] Nucleation efficiency of R134a as a sensitive liquid for superheated drop emulsion detector
    Das, Mala
    Sarkar, R.
    Mondal, P. K.
    Saha, S.
    Chatterjee, B. K.
    Roy, S. C.
    PRAMANA-JOURNAL OF PHYSICS, 2010, 75 (04): : 675 - 682
  • [38] Nucleation efficiency of R134a as a sensitive liquid for superheated drop emulsion detector
    Mala Das
    R. Sarkar
    P. K. Mondal
    S. Saha
    B. K. Chatterjee
    S. C. Roy
    Pramana, 2010, 75 : 675 - 682
  • [39] A position-sensitive neutron spectrometer/dosimeter based on pressurized superheated drop (bubble) detectors
    d'Errico, F
    Nath, R
    Holland, SK
    Lamba, M
    Patz, S
    Rivard, MJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (1-2): : 113 - 118
  • [40] Energy- and angle-differential neutron fluence measurements with superheated drop (bubble) detectors
    d'Errico, F
    Matzke, M
    Siebert, BRL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (1-2): : 277 - 290