Intraoperative transesophageal echocardiography for evaluation of mitral valve repair

被引:0
|
作者
Kawano, H [1 ]
Mizoguchi, T [1 ]
Aoyagi, S [1 ]
机构
[1] Kurume Univ, Sch Med, Dept Surg, Kurume, Fukuoka 8300011, Japan
来源
JOURNAL OF HEART VALVE DISEASE | 1999年 / 8卷 / 03期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: Although mitral valve repair is a well-established procedure, incorrect assessment of the repaired valve may occasionally lead to the need for reoperation. This study was performed to evaluate the accuracy of color Doppler in assessing the competence of the repaired mitral valve. Methods: Transesophageal echocardiography (TEE) and left ventriculography were each performed in 72 patients to compare the two techniques and a semiquantitative index derived. Using this relationship, post bypass intraoperative TEE was then performed in 34 patients who underwent mitral valve repair, in order to assess the competence of the repaired valve. Results: Significant differences were apparent in maximal regurgitant mosaic area between angiographic grade 0, and grades 1+ (p = 0.0006), 1+ and 2+ (p <0.0001) and 2+ and 3+ (p = 0.0010). A maximal regurgitant area <2 cm(2) predicted angiographic grade as 0 (sensitivity 100%, specificity 95%), an area of 2-4 cm(2) as 1+ (sensitivity 82%, specificity 100%), an area of 4-7 cm(2) as 2+ (sensitivity 78%, specificity 90%), and an area >7 cm(2) as grade 3+ or 4+ (sensitivity 79%, specificity 93%). All 34 patients completed valve repair with the maximal regurgitant mosaic area <2.5 cm2. Postoperative left ventriculography showed grade +1 in only five patients; four of these completed mitral valve repair with a maximal mosaic area >2.0 cm(2) as assessed by post bypass intraoperative TEE. During follow up, transthoracic echocardiography (TTE) detected recurrent mitral regurgitation which required mitral valve replacement in one patient, and rapid progression of mitral regurgitation in three patients. Conclusions: It is important that mitral valve repair should be completed with a maximal mosaic area <2.0 cm2 as assessed by intraoperative TEE, in order to reduce the need for reoperation.
引用
收藏
页码:287 / 293
页数:7
相关论文
共 50 条
  • [31] Transesophageal Echocardiography and Mitral Valve Repair: Chasing a "Not-So-Moving" Target
    Saraf, Rabya
    Montealegre-Gallegos, Mario
    Mahmood, Feroze
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2016, 30 (02) : 573 - 573
  • [32] Abnormal Mitral Valve Apparatus in a Case of Hypertrophic Obstructive Cardiomyopathy: Intraoperative Transesophageal Echocardiography
    Aggarwal, Neelam
    Khanuja, Jasbir Singh
    Arora, Sameer Saurabh
    Maria, Rahul
    ANNALS OF CARDIAC ANAESTHESIA, 2018, 21 (03) : 315 - 318
  • [33] Transesophageal Echocardiography-Related Complications During Mitral Valve Repair in Dogs
    Kurogochi, Kentaro
    Takahashi, Arane
    Nii, Yasuyuki
    Suzuki, Tomoya
    Mizuno, Masashi
    Uechi, Masami
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2025, 39 (02)
  • [34] Intraoperative Three-Dimensional Transesophageal Echocardiography: Reconstruction of Mitral Valve Ring Abscess
    Crain, Matthew A.
    Fazi, Alyssa
    Hayanga, Heather K.
    Cook, Chris C.
    Ellison, Matthew B.
    Sloyer, Daniel A.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2022, 36 (08) : 2563 - 2567
  • [35] THE EVALUATION OF THE RESULTS OF VALVE RECONSTRUCTIONS USING INTRAOPERATIVE, TRANSESOPHAGEAL ECHOCARDIOGRAPHY (TEE)
    DREXLER, M
    ERBEL, R
    MOHRKAHALY, S
    MEYER, J
    ZEITSCHRIFT FUR KARDIOLOGIE, 1986, 75 : 28 - 28
  • [36] Atrioventricular Groove Hematoma During Mitral Valve/Tricuspid Valve Repair: Transesophageal Echocardiography Characteristics
    Kumar, Aseem
    Fitzsimons, Brian
    Trombetta, Carlos
    ANESTHESIA AND ANALGESIA, 2013, 116 (05): : 986 - 988
  • [37] Three-dimensional transesophageal echocardiography for determination of the mitral valve area after mitral valve repair surgery for mitral stenosis
    Kang, Woon-Seok
    Ko, Sung-Min
    Lee, Younsuk
    Oh, Chung-Sik
    Kwon, Mi-Young
    Muhammad, Hasmizy
    Kim, Seong-Hyop
    Kim, Tae-Yop
    JOURNAL OF CARDIOVASCULAR SURGERY, 2016, 57 (04): : 606 - 614
  • [38] Intraoperative transesophageal echocardiography in valve replacement surgery
    Rosenhek, R
    Binder, T
    Maurer, G
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2002, 19 (08): : 701 - 707
  • [39] Diagnosis of mitral valve aneurysms by transesophageal echocardiography
    Roguin, A
    Rinkevich, D
    Milo, S
    Reisner, SA
    AMERICAN HEART JOURNAL, 1996, 132 (03) : 689 - 691
  • [40] Transesophageal echocardiography during mitral valve repair underestimates mitral valve area by pressure half-time calculation
    Poh, KK
    Hong, ECT
    Yang, H
    Lim, YT
    Yeo, TC
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 108 (02) : 177 - 180