Image-guided cardiac cell delivery using high-resolution small-animal ultrasound

被引:42
|
作者
Rodriguez-Porcel, M
Gheysens, O
Chen, IY
Wu, JC
Gambhir, SS
机构
[1] Mayo Clin Rochester, Dept Internal Med, Div Cardiovasc Dis, Rochester, MN 55905 USA
[2] Stanford Univ, Mol Imaging Program, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[4] Katholieke Univ Leuven, B-3000 Louvain, Belgium
关键词
ultrasound; molecular imaging; myocardium; animal models; bioluminescence;
D O I
10.1016/j.ymthe.2005.07.532
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Open-chest cardiac injection is the preferred delivery method for cardiac gene and stem cell therapy in small animals, but it is invasive and the operator is unable to see the actual delivery site. High-resolution ultrasound has recently been developed for small-animal imaging. We tested the hypothesis that image-guided cardiac cell delivery using high-resolution ultrasound guidance is feasible and reproducible. Sprague-Dawley rats (n = 11) were imaged using high-resolution ultrasound, and stably transfected cardiomyoblasts (plasmid-CMV-firefly luciferase) were injected into the anterior cardiac wall under ultrasound guidance (parasternal long-axis view), using a 28-gauge needle. After injection, bioluminescence imaging was performed using a cooled charged-coupled camera. Injection was successful in all animals and was associated with no mortality. The signal detected was positively correlated with the amount of cells transplanted (R-2 = 0.94, P = 0.03) and highly correlated with ex vivo assays (R-2 = 0.82). In addition, the optical signal could be followed longitudinally using bioluminescence imaging. Ultrasound image-guided cardiac cell delivery is an effective, safe, and reproducible way to perform cell delivery to a specific myocardial region and can be combined with assessment of cardiac function. We are confident that the use of these technologies will play a significant role in the future of gene and cell therapy.
引用
收藏
页码:1142 / 1147
页数:6
相关论文
共 50 条
  • [21] Image-guided orbital surgery: a preclinical validation study using a high-resolution physical model
    Khan, Rizwana, I
    McElhinney, Kealan
    Dickson, Andrew
    Kileen, Ronan P.
    Murphy, Conor
    O'Brien, Donncha F.
    [J]. BMJ OPEN OPHTHALMOLOGY, 2024, 9 (01):
  • [22] Dose painting by dynamic irradiation delivery on an image-guided small animal radiotherapy platform
    Van Hoof, Stefan J.
    Verde, Joana B.
    Verhaegen, Frank
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1095):
  • [23] A Prototype High-Resolution Small-Animal PET Scanner Dedicated to Mouse Brain Imaging
    Yang, Yongfeng
    Bec, Julien
    Zhou, Jian
    Zhang, Mengxi
    Judenhofer, Martin S.
    Bai, Xiaowei
    Di, Kun
    Wu, Yibao
    Rodriguez, Mercedes
    Dokhale, Purushottam
    Shah, Kanai S.
    Farrell, Richard
    Qi, Jinyi
    Cherry, Simon R.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (07) : 1130 - 1135
  • [24] Performance of a PET Insert for High-Resolution Small-Animal PET/MRI at 7 Tesla
    Stortz, Greg
    Thiessen, Jonathan D.
    Bishop, Daryl
    Khan, Muhammad Salman
    Kozlowski, Piotr
    Retiere, Fabrice
    Schellenberg, Graham
    Shams, Ehsan
    Zhang, Xuezhu
    Thompson, Christopher J.
    Goertzen, Andrew L.
    Sossi, Vesna
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (03) : 536 - 542
  • [25] Image-guided focused ultrasound-mediated molecular delivery to breast cancer in an animal model
    Margolis, Ryan
    Basavarajappa, Lokesh
    Li, Junjie
    Obaid, Girgis
    Hoyt, Kenneth
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (15):
  • [26] Development of an image-guided robot for small animal research
    Kazanzides, Peter
    Chang, Jenghwa
    Iordachita, Iulian
    Li, Jack
    Ling, C. Clifton
    Fichtinger, Gabor
    [J]. COMPUTER AIDED SURGERY, 2007, 12 (06) : 357 - 365
  • [27] Registration of a needle-positioning robot to high-resolution 3-D ultrasound and computed tomography for image-guided interventions in small animals
    Waspe, Adam C.
    Lacefield, James C.
    Holdsworth, David W.
    Fenster, Aaron
    [J]. MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2, 2008, 6918
  • [28] Dosimetric Analysis of Small Animal Image-Guided Irradiator Using High Resolution Optical CT Imaging of 3D Dosimeters
    Na, Y.
    Qian, X.
    Adamovics, J.
    Wuu, C.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3401 - 3401
  • [29] Spatially Fractionated Radiotherapy using an Image-guided Small Animal Irradiation System
    Sharma, S.
    Webber, J.
    Koonce, N.
    Griffine, R. J.
    Penagaricano, J.
    Corry, P. M.
    Moros, E. G.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S547 - S547
  • [30] Multi-Energy Cone Beam CT Image-Guided Intensity-Modulated Small-Animal Irradiation Platform
    Zhong, Y.
    Hu, X.
    Liu, H.
    Lai, Y.
    Shen, C.
    Jia, X.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E251 - E251