A new method for measuring the absolute efficiency of isotope separation on-line systems

被引:13
|
作者
Lecesne, N
Villari, ACC
Angelique, JC
Bertrand, P
Blank, B
Clapier, F
DelasHeras, F
Ducourtieux, M
Foury, P
Jardin, P
Joubert, A
LepineSzily, A
Leroy, R
Lewitowicz, M
Liang, CF
Mandin, J
Marry, C
Maunoury, L
Obert, J
Orr, NA
Pacquet, JY
Paris, P
Potier, JC
Proust, J
Putaux, JC
Robert, E
SaintLaurent, MG
Sortais, P
机构
[1] INST SCI MAT & RAYONNEMENT, LPC, F-14050 CAEN, FRANCE
[2] CEN BORDEAUX GRADIGNAN, F-33175 GRADIGNAN, FRANCE
[3] INST PHYS NUCL, F-91406 ORSAY, FRANCE
[4] IFUSP, BR-01498 SAO PAULO, BRAZIL
[5] CTR SPECTROMETRIE NUCL & SPECTROMETRIE MASSE, F-91406 ORSAY, FRANCE
关键词
D O I
10.1016/S0168-583X(96)01029-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new method for measuring the absolute efficiency of Isotope Separation On Line (ISOL) systems is described, The overall efficiency is deduced from the ratio between the rate of the radioactive beam detected after analysis and the rate of incident radioactive beam in the target, It is shown that the unfolding of the different efficiencies, i,e., diffusion, effusion, ionisation and transport allows us to deduce the diffusion constants when the absolute efficiency data is obtained as a function of the target temperature, Using this technique we extracted the fundamental Arrhenius constants for diffusion of Ar and Ne in Carbon targets used in the SIRa experiments at GANIL.
引用
收藏
页码:141 / 145
页数:5
相关论文
共 50 条
  • [21] A new measuring system of an on-line rotational rheometer
    Kemblowski, Z
    Sek, J
    Owczarz, P
    INZYNIERIA CHEMICZNA I PROCESOWA, 1998, 19 (01): : 129 - 144
  • [22] EURISOL: an European Isotope Separation On-Line radioactive ion beam facility
    Bonaccorso, A.
    Prete, G.
    12TH CONFERENCE ON THEORETICAL NUCLEAR PHYSICS IN ITALY, 2009, 168
  • [23] More efficiency with cleaning agents through on-line measuring of slime
    Goll, D.
    WOCHENBLATT FUR PAPIERFABRIKATION, 2007, 135 (17): : 914 - 915
  • [24] MEASURING MOISTURE-CONTENT ON-LINE BY INFRARED METHOD
    HARBERT, FC
    SJOBERG, B
    BAK, J
    CONTROL AND INSTRUMENTATION, 1974, 6 (01): : 36 - 37
  • [25] AN ON-LINE METHOD FOR MEASURING HEART RATE IN CONDITIONING EXPERIMENTS
    FITZGERALD, RD
    VARDARIS, RM
    TEYLER, TJ
    PSYCHOPHYSIOLOGY, 1968, 4 (03) : 352 - +
  • [26] A New On-Line Method of Measuring Air Leakage Rate of Steam Turbine Vacuum System
    Guo Ying
    Wang Xuetong
    Zhou Guangshun
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [27] Separation of saikosaponins by on-line sample stacking CE method
    Sheng, PW
    Huang, WY
    Sheu, SJ
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2003, 11 (03) : 209 - 213
  • [28] On-line systems for continuous water and gas isotope ratio measurements
    Huber, C
    Leuenberger, M
    ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2005, 41 (03) : 189 - 205
  • [29] A new on-line fault detection method for digital system - Timing separation fault dictionary
    Chen, SJ
    Wu, ZL
    Wang, YF
    Hong, BR
    ICEMI'99: FOURTH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 1999, : 944 - 947
  • [30] Measurements of isotope and elemental ratios of air from polar ice with a new on-line extraction method
    Huber, C
    Leuenberger, M