Comparison of measurement accuracy between two types of wrist goniometer systems

被引:48
|
作者
Jonsson, P
Johnson, PW
机构
[1] Sahlgrens Univ Hosp, Environm & Occupat Med Sect, SE-41266 Gothenburg, Sweden
[2] Univ Washington, Dept Environm Hlth, Seattle, WA 98195 USA
关键词
wrist; goniometer and accuracy;
D O I
10.1016/S0003-6870(01)00036-9
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Studies have shown that wrist goniometers are prone to measurement errors, particularly due to crosstalk. This study compared two wrist goniometer systems: a commonly used biaxial, single transducer (System A) and a biaxial, two-transducer (System B). Wrist angles, range of movement and crosstalk results were compared. With the wrist in 90 degrees of pronation, eight subjects were placed in 20 different wrist postures between -40 degrees and 40 degrees of flexion/extension and between -10 degrees and 20 degrees of deviation. Relative to System B, System A had larger measurement errors and was more prone to crosstalk. There may be two sources of crosstalk: (1) intrinsic crosstalk associated with the design, application and twisting of the goniometer transducer when on the wrist, and (2) extrinsic crosstalk associated with the anatomy and complex movement of the wrist joint. It appears that the majority of the radial/ulnar crosstalk measured with System A was intrinsic crosstalk due to the twisting of the goniometer transducer. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:599 / 607
页数:9
相关论文
共 50 条
  • [21] The accuracy of goniometric measurements of proximal interphalangeal joints in fresh cadavers: Comparison between methods of measurement, types of goniometers, and fingers
    Kato, Masami
    Echigo, Ayumu
    Ohta, Hisaaki
    Ishiai, Sumio
    Aoki, Mitsuhiro
    Tsubota, Sadako
    Uchiyama, Eiichi
    JOURNAL OF HAND THERAPY, 2007, 20 (01) : 12 - 18
  • [22] Comparison Between Two Types of Educational Computer Games
    Dedeaux, Timothy
    Hartsell, Taralynn
    SIMULATION & GAMING, 2018, 49 (06) : 661 - 674
  • [23] A comparison between two types of Fuzzy TOPSIS Method
    Madi, Elissa Nadia
    Garibaldi, Jonathan M.
    Wagner, Christian
    2015 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC 2015): BIG DATA ANALYTICS FOR HUMAN-CENTRIC SYSTEMS, 2015, : 291 - 297
  • [24] Comparison of statistical models for characterizing continuous differences between two biomechanical measurement systems
    Koska, Daniel
    Oriwol, Doris
    Maiwald, Christian
    JOURNAL OF BIOMECHANICS, 2023, 149
  • [25] Accuracy and precision of two in-shoe pressure measurement systems
    Hsiao, HW
    Guan, JH
    Weatherly, M
    ERGONOMICS, 2002, 45 (08) : 537 - 555
  • [26] The measurement accuracy of two electronic jaw recording systems.
    Hugger, A
    Kunstmann, S
    Berntien, U
    Stuttgen, U
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 1125 - 1125
  • [27] Measurement of blood glucose:: comparison between different types of specimens
    Carstensen, Bendix
    Lindstrom, J.
    Sundvall, J.
    Borch-Johnsen, K.
    Tuomilehto, J.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2008, 45 : 140 - 148
  • [28] MEASUREMENT OF THE DIFFERENCE BETWEEN TWO ORTHOGONALITY TYPES IN BANACH SPACES
    Mizuguchi, Hiroyasu
    JOURNAL OF NONLINEAR AND CONVEX ANALYSIS, 2018, 19 (09) : 1579 - 1586
  • [29] Virtual goniometric measurement of the forearm, wrist, and hand: A double-blind psychometric study of a digital goniometer
    Guvenc, Busra
    Kuru, Cigdem Ayhan
    Namaldi, Seda
    Kuru, Ilhami
    JOURNAL OF HAND THERAPY, 2025, 38 (01) : 103 - 112
  • [30] A comparison between two methods for measuring limb resistances with wrist and ankle electrodes
    Jaffrin, Michel Y.
    Bousbiat, Sana
    Dongmo, Edwige
    MEDICAL ENGINEERING & PHYSICS, 2011, 33 (08) : 943 - 949