Comparison of measurement accuracy between two types of wrist goniometer systems

被引:48
|
作者
Jonsson, P
Johnson, PW
机构
[1] Sahlgrens Univ Hosp, Environm & Occupat Med Sect, SE-41266 Gothenburg, Sweden
[2] Univ Washington, Dept Environm Hlth, Seattle, WA 98195 USA
关键词
wrist; goniometer and accuracy;
D O I
10.1016/S0003-6870(01)00036-9
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Studies have shown that wrist goniometers are prone to measurement errors, particularly due to crosstalk. This study compared two wrist goniometer systems: a commonly used biaxial, single transducer (System A) and a biaxial, two-transducer (System B). Wrist angles, range of movement and crosstalk results were compared. With the wrist in 90 degrees of pronation, eight subjects were placed in 20 different wrist postures between -40 degrees and 40 degrees of flexion/extension and between -10 degrees and 20 degrees of deviation. Relative to System B, System A had larger measurement errors and was more prone to crosstalk. There may be two sources of crosstalk: (1) intrinsic crosstalk associated with the design, application and twisting of the goniometer transducer when on the wrist, and (2) extrinsic crosstalk associated with the anatomy and complex movement of the wrist joint. It appears that the majority of the radial/ulnar crosstalk measured with System A was intrinsic crosstalk due to the twisting of the goniometer transducer. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:599 / 607
页数:9
相关论文
共 50 条
  • [1] Comparison of measurement accuracy between two wrist goniometer systems during pronation and supination
    Johnson, PW
    Jonsson, P
    Hagberg, M
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2002, 12 (05) : 413 - 420
  • [2] Comparison of the Wrist Range of Motion Measurement between Inertial Measurement Unit Glove, Smartphone Device and Standard Goniometer
    Surangsrirat, Decho
    Bualuangngam, Tapiya
    Sri-iesaranusorn, Panyawut
    Chaiyaroj, Attawit
    Buekban, Chatchai
    Thanawattano, Chusak
    Poopitaya, Sompob
    APPLIED SCIENCES-BASEL, 2022, 12 (07):
  • [3] Comparison of an Angle Finder and Universal Goniometer for Measurement of Wrist Flexion and Extension
    Byars, Allyn
    Greenwood, Mike
    Greenwood, Lori
    Reed, Amanda S.
    Pape, Mark W.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S280 - S280
  • [4] Comparison Between Two Types of Seismic Tests of Racking Systems
    Bové, Oriol
    Ferrer, Miquel
    Almansa, Francesc López
    Roure, Francesc
    Bové, Oriol (oriol.bove@upc.edu), 1992, John Wiley and Sons Inc (04): : 2 - 4
  • [5] Comparison between two measurement systems for triglyceride in Korea
    Lim, J.
    Kwon, G. C.
    CLINICA CHIMICA ACTA, 2022, 530 : S427 - S428
  • [6] A comparison of the accuracy of two types of quadrature formulae
    Martin, ES
    BIOMETRIKA, 1932, 24 : 280 - 287
  • [7] COMPARISON OF WEATHERVANE PERFORMANCE BETWEEN TWO TYPES OF FOWT SYSTEMS MOORED TO SPM
    Iijima, Kazuhiro
    Kuroda, Yuiko
    Nihei, Yasunori
    Murai, Motohiko
    PROCEEDINGS OF THE ASME 34TH INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, 2015, VOL 6, 2015,
  • [8] Wrist pressure and angulation during keyboarding: Comparison between two common wrist supports
    Short, Nathan
    Almonroeder, Thomas
    Baumle, Madeline
    Benvenuti, Katelyn
    Bozett, Natalie
    John, Olivia
    Lovasko, Mollie
    Rinaldi, Emily
    WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2022, 71 (04): : 1121 - 1128
  • [9] Goniometer measurement and computer analysis of wrist angles and movements applied to occupational repetitive work
    Hansson, GA
    Balogh, I
    Ohlsson, K
    Rylander, L
    Skerfving, S
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1996, 6 (01) : 23 - 35
  • [10] ESTIMATION OF THE ACCURACY OF A COORDINATE MEASUREMENT BY AN OPTOELECTRONIC GONIOMETER OPERATING IN THE STORAGE MODE
    YAKUSHENKOV, YG
    SOVIET JOURNAL OF OPTICAL TECHNOLOGY, 1992, 59 (02): : 122 - 123