Detection of correlated fission fragments with a twin Frisch-grid ionization chamber

被引:0
|
作者
Chen, Hongfei [1 ]
Sun, XiaoJun [2 ]
Zheng, Pu [1 ]
Xiao, Jun [1 ]
Zhu, Tonghua [1 ]
Sun, Junjie [1 ]
Zhu, Jianyu [3 ]
Cao, Yu [4 ]
Yan, Jie [1 ]
Li, Zhenghong [1 ]
机构
[1] China Acad Engn Phys, Inst Nucl Phys & Chem, Mianyang 621000, Sichuan, Peoples R China
[2] Guangxi Normal Univ, Coll Phys, Guilin 541004, Peoples R China
[3] China Acad Engn Phys, Ctr Strateg Studies, Beijing 10000, Peoples R China
[4] Nucl Power Inst China, Chengdu 610213, Peoples R China
基金
中国国家自然科学基金;
关键词
Instrumentation and methods for heavy-ion reactions and fission studies; Detector modelling and simulations II (electric fields; charge transport; multiplication and induction; pulse formation; electron emission; etc); Charge induction; Wire chambers (MWPC; Thin-gap chambers; drift chambers; drift tubes; proportional chambers etc); NEUTRON-INDUCED FISSION; KINETIC-ENERGY RELEASE;
D O I
10.1088/1748-0221/17/09/P09004
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Twin Frisch-grid ionization chambers (TFGICs) have been widely used in the measurement of total kinetic energy (TKE), angular distribution, mass, and charge of the correlated fission fragments. To study these correlated fission parameters, we have developed a TFGIC with a digital acquisition system for use at both the Chinese Mianyang research reactor (CMRR) and neutron science facility in the Institute of Nuclear Physics and Chemistry (INPC), as well as the China Spallation Neutron Source (CSNS). The distribution of the electric field was investigated with Garfield toolkit, the results showed that the ratio of the electric field of the collect region to the drift region (E-c/E-d) must be greater than a critical value Z (1.78). An individual experiment, carried out with a compound alpha source (Am-241 and Am-243), was used to validate the preliminary performance of this detector. The effects of the electric field on the anode pulse height agreed well with the simulation results. Furthermore, the results also indicated that the energy resolution of (68.40 +/- 1.07) keV at 5.39 MeV (Am-243) and (69.67 +/- 1.09) keV at 5.49 MeV (Am-241) could be achieved. An initial in-beam fission experiment of U-235 reaction with 14MeV neutrons was also performed to test the setup, and the results showed that the reconstructed emission angle could achieve a resolution of 0.221 +/- 0.002 on the difference of the cosines determined from both halves of TFGIC. The present work primarily reported the development of a TFGIC with a digital acquisition system in INPC.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] AN IONIZATION CHAMBER FOR DETECTION OF FISSION FRAGMENTS AGAINST A HIGH ALPHA-PARTICLE BACKGROUND
    NASYROV, F
    PASHKIN, NF
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1966, (02): : 327 - &
  • [32] Position sensitive twin ionization chamber for nuclear fission investigations
    Zeynalov, Shakir
    Sedyshev, Pavel
    Sidorova, Olga
    Shvetsov, Valery
    Svetov, Leonid
    PROCEEDINGS OF THE 2017 INTERNATIONAL CONFERENCE ON APPLICATIONS OF NUCLEAR TECHNIQUES (CRETE17), 2018, 48
  • [33] DELTA-E GAS IONIZATION-CHAMBER FOR FISSION FRAGMENTS
    AJITANAND, NN
    KAPOOR, SS
    KATARIA, SK
    RAO, PNR
    NUCLEAR INSTRUMENTS & METHODS, 1972, 103 (01): : 169 - +
  • [34] An ionization chamber with Frisch grids for studies of high-energy neutron-induced fission
    Tutin, GA
    Ryzhov, IV
    Eismont, VP
    Kireev, AV
    Condé, H
    Elmgren, K
    Olsson, N
    Renberg, PU
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 457 (03): : 646 - 652
  • [35] A DOUBLE IONIZATION-CHAMBER FOR FISSION FRAGMENT DETECTION
    CHEPIGIN, VI
    STEPANTSOV, SV
    NAGY, S
    TERAKOPIAN, GM
    VORONIN, AS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 220 (2-3): : 419 - 424
  • [36] Optimization of shielding electrode lengths of virtual Frisch-grid CdZnTe radiation detector for gamma-ray detection
    Jo, Woo Jin
    Kim, Han Soo
    Ha, Jang Ho
    Jeong, Manhee
    CURRENT APPLIED PHYSICS, 2015, 15 : S51 - S56
  • [37] USE OF PULSE IONIZATION CHAMBER FOR MEASUREMENT OF ANGULAR + ENERGY DISTRIBUTIONS OF FISSION FRAGMENTS
    BOCHAGOV, BA
    FADEEV, VI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1964, (01) : 80 - &
  • [38] IONIZATION CHAMBER TECHNIQUE FOR STUDIES OF EXCITED STATES AND ANGULAR CORRELATION OF FISSION FRAGMENTS
    KHARE, LR
    ROY, RR
    BRITISH JOURNAL OF APPLIED PHYSICS, 1962, 13 (02): : 80 - &
  • [39] Spatial- and Time-Correlated Detection of Fission Fragments
    Granja, C.
    Kraus, V.
    Kopatch, Y.
    Telezhnikov, S. A.
    Vacik, J.
    Tomandl, I.
    Platkevic, M.
    Pospisil, S.
    CNR*11 - THIRD INTERNATIONAL WORKSHOP ON COMPOUND NUCLEAR REACTIONS AND RELATED TOPICS, 2012, 21
  • [40] Spatially Correlated and Coincidence Detection of Fission Fragments with the Pixel Detector Timepix
    Granja, Carlos
    Kraus, Vaclav
    Jakubek, Jan
    Pospisil, Stanislav
    Masek, Petr
    Vykydal, Zdenek
    Platkevic, Michal
    Kohout, Zdenek
    Kopatch, Yuri
    Telezhnikov, Sergei A.
    Koester, Ulli
    Vacik, Jiri
    Tomandl, Ivo
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1578 - 1584