Generation of microdamage around endosseous implants

被引:22
|
作者
Warreth, Abdulhadi [1 ]
Polyzois, Ioannis [1 ]
Lee, Clive T. [2 ]
Claffey, Noel [1 ]
机构
[1] Trinity Coll Dublin, Sch Dent Sci, Dept Restorat Dent & Periodontol, Dublin, Ireland
[2] Royal Coll Surgeons Ireland, Dept Anat, Dublin 2, Ireland
关键词
endosseous implants; microdamage; osseointegration; BONE-FORMATION ADJACENT; FATIGUE DAMAGE; ACCUMULATION; FAILURE; MODE;
D O I
10.1111/j.1600-0501.2009.01808.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The aim of this study was to investigate the occurrence of microdamage as a result of osteotomy preparation and/or insertion of endosseous screw-shaped titanium implants into the dog mandible. Materials and methods The mandibular premolar regions of four young adult male Beagle dogs were used for the study. Four implant sites were prepared in the edentulous area of each mandible on each side and the sites were divided into four experimental groups. Group I included sites that contained an osteotomy preparation only. Group II included sites that contained an osteotomy preparation and were tapped but did not receive any implant. Group III included sites that contained an osteotomy preparation and were not tapped but received an implant. Group IV included sites that contained an osteotomy preparation and were tapped before implant placement. Control sites (Group V) were randomly selected from different mandibular sites. Ground sections were prepared from biopsies taken at 2 days and were examined using epifluorescence microscopy. Total number and length of microcracks for each side were compared (left vs. right) using descriptive statistical methods. Results The control group (V) had fewer microcracks compared with the modalities I-IV. There were no differences in microcrack lengths between the jaw sides, treatment modalities, jaw regions and between the treatment modalities and controls. Conclusions The results of this study suggest that most of the microcracks were generated by the osteotomy preparation and the other modalities did not appear to have any major additional effects. To cite this article:Warreth A, Polyzois I, Lee CT, Claffey N. Generation of microdamage around endosseous implants.Clin. Oral Impl. Res. 20, 2009; 1300-1306.doi: 10.1111/j.1600-0501.2009.01808.x.
引用
收藏
页码:1300 / 1306
页数:7
相关论文
共 50 条
  • [21] Radiographic assessment of changes in marginal bone around endosseous implants supporting mandibular overdentures
    Batenburg, RHK
    Meijer, HJA
    Geraets, WGM
    van der Stelt, PF
    DENTOMAXILLOFACIAL RADIOLOGY, 1998, 27 (04) : 221 - 224
  • [22] The effect of rhBMP-2 around endosseous implants with and without membranes in the canine model
    Jones, Archie A.
    Buser, Daniel
    Schenk, Robert
    Wozney, John
    Cochran, David L.
    JOURNAL OF PERIODONTOLOGY, 2006, 77 (07) : 1184 - 1193
  • [23] Effect of Magnetic Field on Bone Healing around Endosseous Implants - An In-vivo Study
    Gujjalapudi, Mahalakshmi
    Anam, Chandrasekar
    Mamidi, Praveen
    Chiluka, Radha
    Kumar, A. Gautam
    Bibinagar, Ragini
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (10) : ZF1 - ZF4
  • [24] TISSUE ADAPTATION TO ENDOSSEOUS IMPLANTS
    HURT, DF
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1988, 46 (05) : 351 - 351
  • [25] Materials for endosseous dental implants
    Wataha, JC
    JOURNAL OF ORAL REHABILITATION, 1996, 23 (02) : 79 - 90
  • [26] Finite element analysis of the stresses around endosseous implants in various reconstructed mandibular models
    Nagasao, T
    Kobayashi, M
    Tsuchiya, Y
    Kaneko, T
    Nakajima, T
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2002, 30 (03) : 170 - 177
  • [27] Dental endosseous implants - An update
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2004, 135 (01): : 92 - 97
  • [28] PIXE and micro-PIXE studies of ion release around endosseous implants in animals
    INFN, Legnaro, Italy
    Nucl Instrum Methods Phys Res Sect B, (289-293):
  • [29] PIXE and micro-PIXE studies of ion release around endosseous implants in animals
    Egeni, GP
    Jaksic, M
    Moschini, G
    Passi, P
    Piattelli, A
    Rossi, P
    Rudello, V
    Tauro, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 109 : 289 - 293
  • [30] Dental endosseous implants: An update
    不详
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1996, 127 (08): : 1238 - 1239