Generation of microdamage around endosseous implants

被引:22
|
作者
Warreth, Abdulhadi [1 ]
Polyzois, Ioannis [1 ]
Lee, Clive T. [2 ]
Claffey, Noel [1 ]
机构
[1] Trinity Coll Dublin, Sch Dent Sci, Dept Restorat Dent & Periodontol, Dublin, Ireland
[2] Royal Coll Surgeons Ireland, Dept Anat, Dublin 2, Ireland
关键词
endosseous implants; microdamage; osseointegration; BONE-FORMATION ADJACENT; FATIGUE DAMAGE; ACCUMULATION; FAILURE; MODE;
D O I
10.1111/j.1600-0501.2009.01808.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The aim of this study was to investigate the occurrence of microdamage as a result of osteotomy preparation and/or insertion of endosseous screw-shaped titanium implants into the dog mandible. Materials and methods The mandibular premolar regions of four young adult male Beagle dogs were used for the study. Four implant sites were prepared in the edentulous area of each mandible on each side and the sites were divided into four experimental groups. Group I included sites that contained an osteotomy preparation only. Group II included sites that contained an osteotomy preparation and were tapped but did not receive any implant. Group III included sites that contained an osteotomy preparation and were not tapped but received an implant. Group IV included sites that contained an osteotomy preparation and were tapped before implant placement. Control sites (Group V) were randomly selected from different mandibular sites. Ground sections were prepared from biopsies taken at 2 days and were examined using epifluorescence microscopy. Total number and length of microcracks for each side were compared (left vs. right) using descriptive statistical methods. Results The control group (V) had fewer microcracks compared with the modalities I-IV. There were no differences in microcrack lengths between the jaw sides, treatment modalities, jaw regions and between the treatment modalities and controls. Conclusions The results of this study suggest that most of the microcracks were generated by the osteotomy preparation and the other modalities did not appear to have any major additional effects. To cite this article:Warreth A, Polyzois I, Lee CT, Claffey N. Generation of microdamage around endosseous implants.Clin. Oral Impl. Res. 20, 2009; 1300-1306.doi: 10.1111/j.1600-0501.2009.01808.x.
引用
收藏
页码:1300 / 1306
页数:7
相关论文
共 50 条
  • [1] Microdamage adjacent to endosseous implants
    Huja, SS
    Katona, TR
    Burr, DB
    Garetto, LP
    Roberts, WE
    BONE, 1999, 25 (02) : 217 - 222
  • [2] Periodontal tissues and their counterparts around endosseous implants
    Listgarten, M. A.
    Lang, N. P.
    Schroeder, H. E.
    Schroeder, A.
    CLINICAL ORAL IMPLANTS RESEARCH, 1991, 2 (01) : 1 - 19
  • [3] Wound healing around endosseous implants in experimental diabetes
    Nevins, ML
    Karimbux, NY
    Weber, HP
    Giannobile, WV
    Fiorellini, JP
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1998, 13 (05) : 620 - 629
  • [4] Analysis of strain around endosseous dental implants opposing natural teeth or implants
    Hekimoglu, C
    Anil, N
    Cehreli, MC
    JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (05): : 441 - 446
  • [5] Early wound healing around endosseous implants: A review of the literature
    Raghavendra, S
    Wood, MC
    Taylor, TD
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2005, 20 (03) : 425 - 431
  • [6] ENDOSSEOUS IMPLANTS
    SEYMOUR, MS
    BRITISH DENTAL JOURNAL, 1971, 131 (04) : 140 - &
  • [7] Endosseous implants
    不详
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2001, 132 (10): : 1452 - 1453
  • [8] Automated measuring of mineralized bone fraction around endosseous implants.
    Murdock, GP
    Mitchell, JC
    Carr, AB
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 3130 - 3130
  • [9] A COMPARISON OF METHODS TO ASSESS MARGINAL BONE HEIGHT AROUND ENDOSSEOUS IMPLANTS
    MEIJER, HJA
    STEEN, WHA
    BOSMAN, F
    JOURNAL OF CLINICAL PERIODONTOLOGY, 1993, 20 (04) : 250 - 253
  • [10] PIXE microbeam analysis of the metallic debris release around endosseous implants
    Buso, GP
    Galassini, S
    Moschini, G
    Passi, P
    Zadro, A
    Uzunov, NM
    Doyle, BL
    Rossi, P
    Provencio, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 240 (1-2): : 91 - 94