共 50 条
Experiences with tungsten coatings in high heat flux tests and under plasma load in ASDEX Upgrade
被引:23
|作者:
Herrmann, A.
[1
]
Greuner, H.
[1
]
Fuchs, J. C.
[1
]
de Marne, P.
[1
]
Neu, R.
[1
]
机构:
[1] EURATOM, Max Planck Inst Plasmaphys, D-85748 Garching, Germany
来源:
关键词:
FACILITY;
CFC;
D O I:
10.1088/0031-8949/2009/T138/014059
中图分类号:
O4 [物理学];
学科分类号:
0702 ;
摘要:
ASDEX Upgrade was operated with about 6400 s plasma discharge during the scientific program in 2007/2008 exploring tungsten as a first wall material in tokamaks. In the first phase, the heating power was restricted to 10 MW. It was increased to 15 MW in the second phase. During this operational period, a delamination of the 200 mu m W-VPS coating happened at 2 out of 128 tiles of the outer divertor and an unscheduled opening was required. In the third phase, ASDEX Upgrade was operated with partly predamaged tiles and up to 15 MW heating power. The target load was actively controlled by N(2)-seeding. This paper presents the screening test of target tiles in the high heat flux test facility GLADIS, experiences with operation and detected damages of the outer divertor as well as the heat load to the outer divertor and the reasons for the toroidal asymmetry of the divertor load.