Magnetic resonance imaging of haemorrhage within reperfused myocardial infarcts: possible interference with iron oxide-labelled cell tracking?

被引:64
|
作者
van den Bos, Ewout J.
Baks, Timo
Moelker, Amber D.
Kerver, Wendy
van Geuns, Robert-Jan
van der Giessen, Willem J.
Duncker, Dirk J.
Wielopolski, Piotr A.
机构
[1] Erasmus MC, Dept Radiol, NL-3015 GD Rotterdam, Netherlands
[2] Erasmus MC, Thoraxctr, Cardiovasc Res Sch Coeur, NL-3015 GD Rotterdam, Netherlands
关键词
magnetic resonance imaging; myocardial infarction; haemorrhage; cells; iron oxide particles;
D O I
10.1093/eurheartj/ehl059
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Magnetic resonance imaging (MRI) has been proposed as a tool to track iron oxide-labelled cells within myocardial infarction (MI). However, infarct reperfusion aggravates microvascular obstruction (MO) and causes haemorrhage. We hypothesized that haemorrhagic MI causes magnetic susceptibility-induced signal voids that may interfere with iron oxide-labelled cell detection. Methods and results Pigs (n = 23) underwent 2 h occlusion of the left circumflex artery. Cine, T2*-weighted, perfusion, and delayed enhancement MRI scans were performed at 1 and 5 weeks, followed by ex vivo high-resolution scanning. At 1 week, MO was observed in 17 out of 21 animals. Signal voids were observed on T2*-weighted scans in five out of eight animals, comprising 24 +/- 22% of the infarct area. A linear correlation was found between area of MO and signal voids (R-2 = 0.87; P = 0.002). At 5 weeks, MO was observed in two out of 13 animals. Signal voids were identified in three out of seven animals. Ex vivo scanning showed signal voids on T2*-weighted scanning in all animals because of the presence of haemorrhage, as confirmed by histology. Signal voids interfered with the detection of iron oxide-labelled cells ex vivo (n = 21 injections). Conclusion Haemorrhage in reperfused MI produces MRI signal voids, which may hamper tracking of iron oxide-labelled cells.
引用
收藏
页码:1620 / 1626
页数:7
相关论文
共 50 条
  • [41] Magnetic Resonance Imaging Tracking of Stem Cells in Vivo Using Iron Oxide Nanoparticles as a Tool for the Advancement of Clinical Regenerative Medicine
    Mahmoudi, Morteza
    Hosseinkhani, Hossein
    Hosseinkhani, Mohsen
    Boutry, Sebastien
    Simchi, Abdolreza
    Journeay, W. Shane
    Subramani, Karthikeyan
    Laurent, Sophie
    CHEMICAL REVIEWS, 2011, 111 (02) : 253 - 280
  • [42] Comparison of Superparamagnetic and Ultrasmall Superparamagnetic Iron Oxide Cell Labeling for Tracking Green Fluorescent Protein Gene Marker with Negative and Positive Contrast Magnetic Resonance Imaging
    Zhang, Zhuoli
    Dharmakumar, Rohan
    Mascheri, Nicole
    Fan, Zhaoyang
    Wu, Shengyong
    Li, Debiao
    MOLECULAR IMAGING, 2009, 8 (03): : 148 - 155
  • [43] In Vivo Tracking of Mesenchymal Stem Cell in Rat Genitalia with Erectile Dysfunction Labeled by Superparamagnetic Iron Oxide Using Magnetic Resonance Imaging and Its Therapeutic Effect
    Oh, Kyung Taek
    Ngoc Ha Hoang
    Park, So-Young
    Lee, Eun Seong
    Kim, Jang Hwan
    Oh, Young Taik
    IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (03)
  • [44] Magnetic resonance imaging (MRI) of inflamed myocardium using iron oxide nanoparticles in patients with acute myocardial infarction - Preliminary results
    Yilmaz, Ali
    Roesch, Sabine
    Klingel, Karin
    Kandolf, Reinhard
    Helluy, Xavier
    Hiller, Karl-Heinz
    Jakob, Peter M.
    Sechtem, Udo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 163 (02) : 175 - 182
  • [45] Ultrasmall Supraparamagnetic Particles of Iron Oxide-enhanced Magnetic Resonance Imaging in the Assessment of Cellular Inflammation after Myocardial Infarction
    Stirrat, Colin G.
    Alam, Shirjel R.
    MacGillivray, Tom J.
    Dweck, Marc R.
    Henriksen, Peter A.
    Newby, David E.
    Semple, Scott
    CIRCULATION, 2014, 130
  • [46] Ultrasmall superparamagnetic particles of iron oxide-enhanced magnetic resonance imaging in the assessment of cellular inflammation after myocardial infarction
    Colin G Stirrat
    Shirjel Alam
    Thomas J MacGillivray
    Calum D Gray
    Marc R Dweck
    Saeed Mirsadraee
    Graham McKillop
    Peter A Henriksen
    David Newby
    Scott Semple
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [47] Ultrasmall superparamagnetic particles of iron oxide-enhanced magnetic resonance imaging in the assessment of cellular inflammation after myocardial infarction
    Stirrat, C.
    Alam, S. R.
    MacGillivray, T. J.
    Gray, C. D.
    Dweck, M. R.
    Mirsadraee, S.
    Semple, S.
    Henriksen, P. A.
    Newby, D. E.
    EUROPEAN HEART JOURNAL, 2015, 36 : 353 - 354
  • [48] Use of magnetic resonance imaging in rat pups to monitor iron-labelled neural stem cell homing after hypoxia-ischemia
    Ashwal, S.
    Obenaus, A.
    Digicaylioglu, M.
    Tone, A.
    Robbins, M.
    Wang, A.
    Tian, H.
    Snyder, E.
    ANNALS OF NEUROLOGY, 2006, 60 : S114 - S115
  • [49] Fluorescent magnetic iron oxide nanoparticles for cardiac precursor cell selection from stromal vascular fraction and optimization for magnetic resonance imaging
    Verma, Vinod Kumar
    Kamaraju, Suguna Ratnakar
    Kancherla, Ravindranath
    Kona, Lakshmi K.
    Beevi, Syed Sultan
    Debnath, Tanya
    Usha, Shalini P.
    Vadapalli, Rammohan
    Arbab, Ali Syed
    Chelluri, Lakshmi Kiran
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2015, 10 : 711 - 726
  • [50] Superparamagnetic Iron Oxide Nanoparticles-Complexed Cationic Amylose for In Vivo Magnetic Resonance Imaging Tracking of Transplanted Stem Cells in Stroke
    Lin, Bing-Ling
    Zhang, Jun-Zhao
    Lu, Lie-Jing
    Mao, Jia-Ji
    Cao, Ming-Hui
    Mao, Xu-Hong
    Zhang, Fang
    Duan, Xiao-Hui
    Zheng, Chu-Shan
    Zhang, Li-Ming
    Shen, Jun
    NANOMATERIALS, 2017, 7 (05):