Can we measure the intraocular pressure when the eyeball is against the pillow in the lateral decubitus position?

被引:12
|
作者
Kim, Ho Soong [1 ,2 ]
Park, Ki Ho [2 ]
Jeoung, Jin Wook [2 ]
机构
[1] Sungmo Eye Hosp, Pusan, South Korea
[2] Seoul Natl Univ, Coll Med, Seoul Natl Univ Hosp, Dept Ophthalmol, Seoul 110744, South Korea
关键词
eye compression; glaucoma; ICare rebound tonometer; intraocular pressure; GOLDMANN APPLANATION TONOMETER; NORMAL-TENSION GLAUCOMA; OPEN-ANGLE GLAUCOMA; OCULAR HYPERTENSION; REBOUND TONOMETER; POSTURAL CHANGE; BODY POSITION; VISUAL-FIELD; REDUCTION; TRIAL;
D O I
10.1111/aos.12151
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the amount of intraocular pressure (IOP) change in the eye against the pillow in the lateral decubitus position (LDP). Methods: Thirty eyes from 15 healthy volunteers (12 men and three women) aged 293 (range 25-37) years participated in this study. Using the rebound tonometer (Icare PRO, Icare Finland Oy, Helsinki, Finland), the IOP of both eyes was checked in sitting, supine, right and left LDPs. In the LDP, the additional IOP measurements were taken with the lower eyeball against the latex pillow. Results: Baseline IOP in the sitting position was 12.7 +/- 1.9mmHg in the right eye and 12.8 +/- 2.2mmHg in the left eye. Ten minutes after shifting from the sitting to the supine position, IOP increased significantly (right eye: +1.4 +/- 1.4mmHg, p=0.006; left eye: +1.8 +/- 1.5mmHg, p=0.001). Changing from the supine to the right and left LDP increased significantly the IOP of dependent eye (right eye: +2.3 +/- 1.8mmHg, p=0.001; left eye: +1.5 +/- 1.8mmHg, p=0.011). When the dependent eye was compressed against the pillow in the LDP, the IOP of the dependent eyes increased significantly after 10min (right eye in the right LDP: +4.1 +/- 4.9mmHg, p=0.011; left eye in the left LDP: +3.4 +/- 3.7mmHg, p=0.006). Conclusion: The IOP was significantly elevated when the eyeball was against the pillow in the LDP.
引用
收藏
页码:E502 / E505
页数:4
相关论文
共 50 条
  • [21] Chronic migraine: (when) should we measure CSF pressure?
    Koen Paemeleire
    Nature Clinical Practice Neurology, 2008, 4 : 422 - 423
  • [22] Can we trust intraocular pressure measurements in eyes with intracameral air?
    Gauti Jóhannesson
    Christina Lindén
    Anders Eklund
    Anders Behndig
    Per Hallberg
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2014, 252 : 1607 - 1610
  • [23] Can we trust intraocular pressure measurements in eyes with intracameral air?
    Johannesson, Gauti
    Linden, Christina
    Eklund, Anders
    Behndig, Anders
    Hallberg, Per
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (10) : 1607 - 1610
  • [24] Effect of Different Head Positions in Lateral Decubitus Posture on Intraocular Pressure in Treated Patients With Open-Angle Glaucoma
    Lee, Tae-Eun
    Yoo, Chungkwon
    Lin, Shan C.
    Kim, Yong Yeon
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (05) : 929 - 936
  • [25] Can the SENSIMED Triggerfish® lens data be used as an accurate measure of intraocular pressure?
    Vitish-Sharma, Parveen
    Acheson, Austin G.
    Stead, Richard
    Sharp, John
    Abbas, Ali
    Hovan, Marta
    Maxwell-Armstrong, Charles
    Guo, Boliang
    King, Anthony J.
    ACTA OPHTHALMOLOGICA, 2018, 96 (02) : e242 - e246
  • [26] Can we rely on “calibrated” central venous pressure to measure pleural pressure at the bedside?
    Alessandro Protti
    Maurizio Cecconi
    Intensive Care Medicine Experimental, 12
  • [27] Can we rely on "calibrated" central venous pressure to measure pleural pressure at the bedside?
    Protti, Alessandro
    Cecconi, Maurizio
    INTENSIVE CARE MEDICINE EXPERIMENTAL, 2024, 12 (01)
  • [28] Intraocular Pressure Curves of Untreated Glaucoma Suspects and Glaucoma Patients in Sitting and Lateral Decubitus Positions Using the Goldmann Applanation Tonometer
    Piven, Ilia
    Glovinsky, Yoseph
    JOURNAL OF GLAUCOMA, 2014, 23 (08) : 541 - 546
  • [29] Where and When Can We Use Google Trends to Measure Issue Salience?
    Mellon, Jonathan
    PS-POLITICAL SCIENCE & POLITICS, 2013, 46 (02) : 280 - 290
  • [30] WHEN DO YOU MEASURE INTRAOCULAR-PRESSURE POSTOPERATIVELY - HOW DO YOU TREAT AND PREVENT ELEVATED POSTOPERATIVE INTRAOCULAR-PRESSURE
    KOLKER, AE
    HOSKINS, HD
    HERSCHLER, J
    OSHER, RH
    THURMOND, JA
    PAPE, LG
    VANBUSKIRK, EM
    NEVYAS, HJ
    KATZEN, LE
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1987, 13 (05): : 568 - 573