Association of night-time home blood pressure with night-time ambulatory blood pressure and target-organ damage: a systematic review and meta-analysis

被引:66
|
作者
Kollias, Anastasios [1 ]
Ntineri, Angeliki [1 ]
Stergiou, George S. [1 ]
机构
[1] Univ Athens, Sch Med, Dept Med 3, Hypertens Ctr STRIDE 7,Sotiria Hosp, 152 Mesogion Ave, Athens 11527, Greece
关键词
ambulatory blood pressure; home blood pressure; night-time blood pressure; nocturnal blood pressure; nondippers; target-organ damage; EUROPEAN-SOCIETY; SELF-MEASUREMENT; PROGNOSTIC VALUE; HYPERTENSION; OFFICE; REPRODUCIBILITY; PREDICTORS; GUIDELINES; ACCURACY; RATIO;
D O I
10.1097/HJH.0000000000001189
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: Night-time ambulatory blood pressure (nABP) is the most important aspect of the blood pressure profile in terms of prognosis. Novel low-cost home monitors allow automated night-time blood pressure monitoring (nHBP). This study reviewed the evidence on the association of nHBP with nABP and preclinical organ damage. Methods: Systematic review and meta-analysis. Results: Analysis of six studies (n = 1404) showed pooled difference between nHBP and nABP (SBP/DBP) at 1.4, 95% confidence interval (CI) 0.3, 2.6/-0.2, 95% CI - 0.9, 0.6 mmHg, whereas the pooled correlation coefficient between nHBP and nABP (SBP/DBP) was r = 0.70, 95% CI 0.59, 0.81/r - 0.72, 95% CI 0.67, 0.77, respectively. Two studies (n = 212) investigated the agreement between nHBP and nABP in detecting nondippers with weighted agreement 77.3% (pooled kappa 0.27, 95% CI 0.08, 0.45). Three studies (n = 954) reported on the association of left ventricular mass index with systolic nHBP and nABP (pooled correlation coefficient r = 0.36, 95% CI 0.23, 0.50 and r = 0.32, 95% CI 0.10, 0.54, respectively, P = NS for comparison). Two studies (n = 950) reported on the association of urinary albumin excretion with systolic nHBP and nABP (pooled r = 0.39, 95% CI 0.21, 0.58 and r = 0.30, 95% CI 0.06, 0.55, respectively, P < 0.01 for comparison). Two studies (n = 350) reported on the association of common carotid intima-media thickness with systolic nHBP and nABP (pooled r = 0.31, 95% CI 0.16, 0.46 and r = 0.35, 95% CI 0.17, 0.53, respectively, P = NS for comparison). Conclusion: The available evidence suggests that nHBP and nABP present similar values and comparable relationship with target-organ damage. Studies on the prognostic value of nHBP are needed.
引用
收藏
页码:442 / 452
页数:11
相关论文
共 50 条
  • [21] THE ASSOCIATION OF NIGHT-TIME SYSTOLIC BLOOD PRESSURE WITH ULTRASOUND MARKERS OF SUBCLINICAL CARDIAC AND VASCULAR DAMAGE
    O'Flynn, Anne Marie
    Curtin, Ronan
    Kearney, Patricia
    [J]. HEART, 2016, 102 : A66 - A66
  • [22] Synergic effect of adiposity and night-time blood pressure on cardiac remodeling and damage
    Sarzani, R.
    Guerra, F.
    Giannini, E.
    Lancioni, L.
    Mancinelli, L.
    Fedecostante, M.
    Barbatelli, P.
    Dessi'-Fulgheri, P.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 : 945 - 945
  • [23] Association of Central Versus Brachial Blood Pressure With Target-Organ Damage Systematic Review and Meta-Analysis
    Kollias, Anastasios
    Lagou, Styliani
    Zeniodi, Maria Elena
    Boubouchairopoulou, Nadia
    Stergiou, George S.
    [J]. HYPERTENSION, 2016, 67 (01) : 183 - 190
  • [24] Night-time blood pressure and new onset kidney disease
    Cuspidi, Cesare
    Grassi, Guido
    [J]. JOURNAL OF HYPERTENSION, 2013, 31 (12) : 2339 - 2341
  • [25] Night-time blood pressure: a role in the prediction and prevention of diabetes?
    Martin K. Rutter
    [J]. Diabetologia, 2016, 59 : 234 - 236
  • [26] Night-time blood pressure: a role in the prediction and prevention of diabetes?
    Rutter, Martin K.
    [J]. DIABETOLOGIA, 2016, 59 (02) : 234 - 236
  • [27] Determinants of day-night difference in blood pressure, a comparison with determinants of daytime and night-time blood pressure
    Musameh, M. D.
    Nelson, C. P.
    Gracey, J.
    Tobin, M.
    Tomaszewski, M.
    Samani, N. J.
    [J]. JOURNAL OF HUMAN HYPERTENSION, 2017, 31 (01) : 43 - 48
  • [28] Home blood pressure is as reliable as ambulatory blood pressure in predicting target-organ damage in hypertension
    Stergiou, George S.
    Argyraki, Katerina K.
    Moyssakis, Ioannis
    Mastorantonakis, Stylianos E.
    Achimastos, Apostolos D.
    Karamanos, Vasilios G.
    Roussias, Leonidas G.
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2007, 20 (06) : 616 - 621
  • [29] Night-time blood pressure and subclinical target organ damage: findings from an irish primary care based population sample
    O'Flynn, A. M.
    Curtin, R. J.
    Perry, I. J.
    Kearney, P. M.
    [J]. JOURNAL OF HUMAN HYPERTENSION, 2013, 27 (10) : 651 - 651
  • [30] IMPLICATION OF NIGHT-TIME MEAN SYSTOLIC BLOOD PRESSURE FOR PREDICTING SUBCLINICAL TARGET ORGAN DAMAGE IN HYPERTENSION: COMPARISON WITH OFFICE CENTRAL BLOOD PRESSURES
    Kim, Darae
    Shim, Chi Young
    Hong, Geu-Ru
    Cho, In Jeong
    Chang, Hyuk-Jae
    Ha, Jong-Won
    Chung, Namsik
    [J]. JOURNAL OF HYPERTENSION, 2016, 34 : E418 - E418