On-line near infrared spectroscopy as a Process Analytical Technology (PAT) tool to control an industrial seeded API crystallization

被引:32
|
作者
Schaefer, C. [1 ,4 ]
Lecomte, C. [2 ]
Clicq, D. [1 ]
Merschaert, A. [2 ]
Norrant, E. [3 ]
Fotiadu, F. [4 ]
机构
[1] UCB Pharma, Analyt Dev Chem, B-1420 Braine Lalleud, Belgium
[2] UCB Pharma, Chem Proc Dev, B-1420 Braine Lalleud, Belgium
[3] UCB Pharma, Innovat & Technol Dev, B-1420 Braine Lalleud, Belgium
[4] Aix Marseille Univ, Ecole Cent Marseille, CNRS, Inst Sci Mol Marseille,UMR 7313, F-13397 Marseille 20, France
关键词
Process Analytical Technology (PAT); Near infrared spectroscopy; On-line measurement; Active pharmaceutical ingredient (API) crystallization; BATCH COOLING CRYSTALLIZATION; NIR SPECTROSCOPY; AT-LINE; CALIBRATION; MODELS; CHEMOMETRICS; SCUTELLAREIN; REGRESSION; PLS;
D O I
10.1016/j.jpba.2013.05.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The final step of an active pharmaceutical ingredient (API) manufacturing synthesis process consists of a crystallization during which the API and residual solvent contents have to be quantified precisely in order to reach a predefined seeding point. A feasibility study was conducted to demonstrate the suitability of on-line NIR spectroscopy to control this step in line with new version of the European Medicines Agency (EMA) guideline [1]. A quantitative method was developed at laboratory scale using statistical design of experiments (DOE) and multivariate data analysis such as principal component analysis (PCA) and partial least squares (PLS) regression. NIR models were built to quantify the API in the range of 9-12% (w/w) and to quantify the residual methanol in the range of 0-3% (w/w). To improve the predictive ability of the models, the development procedure encompassed: outliers elimination, optimum model rank definition, spectral range and spectral pre-treatment selection. Conventional criteria such as, number of PLS factors, R-2, root mean square errors of calibration, cross-validation and prediction (RMSEC, RMSECV, RMSEP) enabled the selection of three model candidates. These models were tested in the industrial pilot plant during three technical campaigns. Results of the most suitable models were evaluated against to the chromatographic reference methods. Maximum relative bias of 2.88% was obtained about API target content. Absolute bias of 0.01 and 0.02% (w/w) respectively were achieved at methanol content levels of 0.10 and 0.13% (w/w). The repeatability was assessed as sufficient for the on-line monitoring of the 2 analytes. The present feasibility study confirmed the possibility to use on-line NIR spectroscopy as a PAT tool to monitor in real-time both the API and the residual methanol contents, in order to control the seeding of an API crystallization at industrial scale. Furthermore, the successful scale-up of the method proved its capability to be implemented in the manufacturing plant with the launch of the new API process. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:194 / 201
页数:8
相关论文
共 50 条
  • [21] Near-infrared reflectance spectroscopy as a process analytical technology tool in Ginkgo biloba extract qualification
    Rosa, Silvia S.
    Barata, Pedro A.
    Martins, Jose M.
    Menezes, Jose C.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (02) : 320 - 327
  • [22] Near infrared spectroscopy as a tool for in-line control of process and material properties of PLA biopolymer
    Becker, Wolfgang
    Inone-Kauffmann, Emilia
    Eckl, Wilhelm
    Eisenreich, Norbert
    TM-TECHNISCHES MESSEN, 2015, 82 (12) : 653 - 662
  • [23] Near-Infrared Spectroscopy as a Process Analytical Technology Tool for Monitoring the Steaming Process of Gastrodiae rhizoma with Multiparameters and Chemometrics
    Zuo, Yamin
    Yang, Jing
    Li, Chen
    Deng, Xuehua
    Zhang, Shengsheng
    Wu, Qing
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2020, 2020
  • [24] On-line monitoring of residual solvent during the pharmaceutical drying process using non-contact infrared sensor: A process analytical technology (PAT) approach
    Tewari, Jagdish
    Dixit, Vivechana
    Malik, Kamal
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 144 (01): : 104 - 111
  • [25] In-line Process Analytical Technology based on qualitative near-infrared spectroscopy modeling - An innovative approach for the pharmaceutical quality control
    Sukowski, L
    Ulmschneider, M
    PHARMAZEUTISCHE INDUSTRIE, 2005, 67 (07): : 830 - 835
  • [26] Real-time determination of critical quality attributes using near-infrared spectroscopy: A contribution for Process Analytical Technology (PAT)
    Rosas, Juan G.
    Blanco, Marcel
    Gonzalez, Josep M.
    Alcala, Mane
    TALANTA, 2012, 97 : 163 - 170
  • [27] On-line near infrared spectrometry associated with chemometrics: A tool for industrial chemical procedures.
    SternaGrataloup, C
    ANALUSIS, 1995, 23 (10) : 483 - 485
  • [28] On-line monitoring of the distillates of a solvent switch process by near-infrared spectroscopy
    Ge, ZH
    Buchanan, B
    Timmermans, J
    De Tora, D
    Ellison, D
    Wyvratt, J
    PROCESS CONTROL AND QUALITY, 1999, 11 (04): : 277 - 287
  • [29] Applications and prospects of on-line near infrared spectroscopy technology in manufacturing of chinese materia medica
    Li, Yang
    Wu, Zhi-Sheng
    Pan, Xiao-Ning
    Shi, Xin-Yuan
    Guo, Ming-Ye
    Xu, Bing
    Qiao, Yan-Jiang
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2014, 34 (10): : 2632 - 2638
  • [30] Applications and Prospects of On-Line Near Infrared Spectroscopy Technology in Manufacturing of Chinese Materia Medica
    Li Yang
    Wu Zhi-sheng
    Pan Xiao-ning
    Shi Xin-yuan
    Guo Ming-ye
    Xu Bing
    Qiao Yan-jiang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (10) : 2632 - 2638