Preparative and analytical size-exclusion chromatography of chitosans

被引:94
|
作者
Ottoy, MH
Varum, KM
Christensen, BE
Anthonsen, MW
Smidsrod, O
机构
[1] Norwegian Biopolymer Laboratory, Department of Biotechnology, Norwegian Univ. of Sci. and Technol.
[2] Research Centre, NORSK HYDRO ASA, N-3901 Porsgrunn
关键词
D O I
10.1016/S0144-8617(96)00096-3
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Two chitosan samples (fraction of acetylated units (F-A) 0.15 and 0.52) were fractionated by preparative size exclusion chromatography (SEC). The molecular weights and molecular weight distributions of the fractions were analyzed by analytical size exclusion chromatography coupled to an on-line low angle laser light scattering detector and a differential refractive index detector (SEC-LALLS-DRI), and their intrinsic viscosities were determined. The exponent (a) of the Mark-Houwink-Kuhn-Sakurada (MHKS) equation was found to be 0.92+/-0.07 and 1.1+/-0.1, respectively, at I=0.1 and pH 4.5. No variation in F-A related to molecular weight was found. Reversible interaction between chitosans and different column packings strongly influenced the log M-V relationships. This interaction was generally most pronounced for the low-F-A chitosan, suggesting that the protonated amino groups are involved. Ammonium acetate buffer reduced this effect and the use of a new type of SEC-packing seemed to eliminate it. The more highly acetylated chitosan also had a more pronounced tendency towards concentration dependent self-association, which most probably involve intermolecular hydrophobic interactions between the acetyl groups. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:253 / 261
页数:9
相关论文
共 50 条
  • [31] SURFACE EFFECTS IN SIZE-EXCLUSION CHROMATOGRAPHY
    SORIA, V
    CAMPOS, A
    FIGUERUELO, JE
    GARCIA, R
    GOMEZ, CM
    PORCAR, I
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 148 - ANYL
  • [32] A Deadenylase Assay by Size-Exclusion Chromatography
    He, Guang-Jun
    Yan, Yong-Bin
    PLOS ONE, 2012, 7 (03):
  • [33] Fluorescence-Detection Size-Exclusion Chromatography - An Analytical Technique with Multiple Applications
    Halan, Vivek
    Maity, Sunit
    Rathore, Anurag S.
    Krull, Ira
    LC GC EUROPE, 2015, 28 (02) : 118 - 121
  • [34] OFF-LINE COMBINATION OF PREPARATIVE ISOTACHOPHORESIS AND SIZE-EXCLUSION CHROMATOGRAPHY IN ANALYSIS OF HUMIC ACIDS
    Radicova, Zdenka
    Bodor, Robert
    Gora, Robert
    Hutta, Milan
    Masar, Marian
    CHEMICKE LISTY, 2013, 107 : S432 - S434
  • [35] ANALYSIS OF COLLOIDS .6. SEMICONDUCTOR COLLOIDS OF HIGH MONODISPERSITY BY PREPARATIVE SIZE-EXCLUSION CHROMATOGRAPHY
    FISCHER, CH
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (17): : 3593 - 3611
  • [36] Selectivity in preparative separations of inorganic electrolytes by size-exclusion chromatography on hypercrosslinked polystyrene and microporous carbons
    Davankov, VA
    Tsyurupa, MP
    Alexienko, NN
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1100 (01) : 32 - 39
  • [37] Fluorescence-Detection Size-Exclusion Chromatography - An Analytical Technique with Multiple Applications
    Halan, Vivek
    Maity, Sunit
    Rathore, Anurag S.
    Krull, Ira
    LC GC NORTH AMERICA, 2014, 32 (12) : 922 - 926
  • [38] Application possibilities of preparative size exclusion chromatography to analytical problems in polymer science
    Laboratory of Macromolecular Chemistry and Nanoscience , Eindhoven University of Technology, Dutch Polymer Institute , P.O. Box 513, 5600 MB Eindhoven, Netherlands
    E-Polymers, 2007, (1-10) : 1 - 10
  • [39] Application possibilities of preparative size exclusion chromatography to analytical problems in polymer science
    Thijs, Hanneke M. L.
    Meier, Michael A. R.
    Schubert, Ulrich S.
    E-POLYMERS, 2007,
  • [40] SIZE-EXCLUSION CHROMATOGRAPHY OF DNA RESTRICTION FRAGMENTS - FRAGMENT LENGTH DETERMINATIONS AND A COMPARISON WITH THE BEHAVIOR OF PROTEINS IN SIZE-EXCLUSION CHROMATOGRAPHY
    ELLEGREN, H
    LAAS, T
    JOURNAL OF CHROMATOGRAPHY, 1989, 467 (01): : 217 - 226