Image-based characterization of microfocus X-ray target failure

被引:0
|
作者
Robinson, Vance S. [1 ]
Raber, Thomas [2 ]
Ross, William R. [3 ]
机构
[1] GE Global Res, Radiat Syst Lab, 1 Res Circle, Niskayuna, NY 12309 USA
[2] GE Global Res, Met Lab, 1 Res Circle, Niskayuna, NY 12309 USA
[3] GE Global Res, Inspect & Metrol Lab, 1 Res Circle, Niskayuna, NY 12309 USA
关键词
Microfocus x-ray; x-ray target; bremsstrahlung x-ray generation;
D O I
10.1117/12.2238968
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray targets in microfocus x-ray tubes fail primarily due to sublimation and evaporation of tungsten while exposed to the electron beam. The temperature at the point of impact of the electron beam depends on the beam energy (200-300 kV), the beam current (<10 mA), the cross section (<1 mm) and the intensity profile. In order to preserve the target for a reasonable lifetime, temperatures at the spot do not typically exceed 2500 C. As tungsten evaporates from the surface of the target, the surface starts to pit and this can affect the x-ray production in multiple ways: the photon flux decreases, the heel effect is enhanced, the effective spot size changes shape and/or size Indirectly, the target damage incurred over time or due to intense use will undermine the image quality by reducing image contrast, changing the resolution or degrading the signal to noise ratio. A detailed description of how x-ray target damage is incurred and the potential impact on image quality is reviewed in detail. Experimental results showing the target damage and associated loss of image quality are discussed.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] A microfocus X-ray tube based on a microstructured X-ray target
    Ihsan, Aamir
    Heo, Sung Hwan
    Cho, Sung Oh
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (21-22): : 3566 - 3573
  • [2] Composite Material Characterization using Microfocus X-ray Computed Tomography Image-based Finite Element Modeling
    Abdul-Aziz, Ali
    Roth, D. J.
    Cotton, R.
    Studor, George F.
    Christiansen, Eric
    Young, P. C.
    MATERIALS EVALUATION, 2013, 71 (02) : 167 - 175
  • [3] Failure analysis using microfocus X-ray imaging
    Bossi, RH
    JOURNAL OF TESTING AND EVALUATION, 1999, 27 (02) : 137 - 142
  • [4] Optimization of X-ray target parameters for a high-brightness microfocus X-ray tube
    Ihsan, Aamir
    Heo, Sung Hwan
    Cho, Sung Oh
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 264 (02): : 371 - 377
  • [5] X-ray crystallography with microfocus X-ray sources
    Arndt, UW
    Bloomer, AC
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES AND OPTICS, 2000, 4144 : 86 - 94
  • [6] Transmission W-Diamond X-Ray Target for High Brightness Microfocus X-Ray Sources
    Tan, Y.
    Kandlakunta, P.
    Liu, R.
    Zhou, S.
    Zhao, T.
    Zhang, T.
    MEDICAL PHYSICS, 2019, 46 (06) : E301 - E301
  • [7] X-ray wavefront characterization with grating interferometry using an x-ray microfocus laboratory source
    Zhao Shuai
    Wang Ke-yi
    Cheng Guang-yu
    Shen Yuan
    Wang Yu-shan
    Zhang Lei
    ADVANCES IN METROLOGY FOR X-RAY AND EUV OPTICS IX, 2020, 11492
  • [8] Microfocus X-ray Tube Based on CNT Array
    Chen, Zexiang
    Wang, Zhihui
    Hu, Tianyong
    Zeng, Yugong
    Tang, Ningjiang
    2013 IEEE 14TH INTERNATIONAL VACUUM ELECTRONICS CONFERENCE (IVEC), 2013,
  • [9] Radioscopy and computed tomography for failure analysis using microfocus X-ray
    Bossi, RH
    Cross, DA
    Mickelsen, RA
    NONDESTRUCTIVE EVALUATION OF MATERIALS AND COMPOSITES, 1996, 2944 : 13 - 20
  • [10] X-ray diffractometry with a microfocus source
    Michaelsen, Carsten
    Wiesmann, Joerg
    Hasse, Bernd
    Preckwinkel, Uwe
    Cordes, Holger
    Yang, Ning
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2008, 64 : C171 - C171