A microfocus X-ray tube based on a microstructured X-ray target

被引:20
|
作者
Ihsan, Aamir [1 ]
Heo, Sung Hwan [1 ]
Cho, Sung Oh [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, Taejon 305701, South Korea
关键词
X-ray tube; X-ray target; Microstructure; Microfocus; MONTE-CARLO-SIMULATION; W/AL-FILM TARGETS; FOCAL SPOT SIZE; COMPUTED-TOMOGRAPHY; SPATIAL-DISTRIBUTION; RESOLUTION; TECHNOLOGY;
D O I
10.1016/j.nimb.2009.08.012
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present a novel concept to develop a microfocus X-ray tube based on a microstructured X-ray target that is irradiated with a nonfocused electron beam. X-ray emissions from the microstructured targets with various morphologies were studied using Monte-Carlo simulation code MCNP5. The calculations revealed that the microstructured targets are quite capable of minimizing the effective X-ray spot size compared with those of conventional transmission-type X-ray targets. Based on the simulation results of X-ray brightness, optimum geometric parameters were derived for the microstructured targets with different morphologies. Moreover, the stability of the microstructured target against heat loads delivered by an electron beam was also investigated under both the continuous and pulsed operation modes. From the analysis, the limitations of the maximum allowable electron beam currents for the stable operation of the X-ray targets are presented. The combination of the microstructured targets and nonfocused electron beam allows the miniaturization of a microfocus X-ray tube by eliminating the needs for massive and complex focusing devices. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3566 / 3573
页数:8
相关论文
共 50 条
  • [1] Optimization of X-ray target parameters for a high-brightness microfocus X-ray tube
    Ihsan, Aamir
    Heo, Sung Hwan
    Cho, Sung Oh
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 264 (02): : 371 - 377
  • [2] X-ray imaging with compound refractive lens and microfocus X-ray tube
    Pina, Ladislav
    Dudchik, Yury
    Jelinek, Vaclav
    Sveda, Libor
    Marsik, Jiri
    Horvath, Martin
    Petr, Ondrej
    [J]. ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS III, 2008, 7077
  • [3] Microfocus X-ray Tube Based on CNT Array
    Chen, Zexiang
    Wang, Zhihui
    Hu, Tianyong
    Zeng, Yugong
    Tang, Ningjiang
    [J]. 2013 IEEE 14TH INTERNATIONAL VACUUM ELECTRONICS CONFERENCE (IVEC), 2013,
  • [4] X-ray crystallography with microfocus X-ray sources
    Arndt, UW
    Bloomer, AC
    [J]. ADVANCES IN LABORATORY-BASED X-RAY SOURCES AND OPTICS, 2000, 4144 : 86 - 94
  • [5] A MICROFOCUS X-RAY TUBE WITH HIGH POWER
    Trubitsyn, A.
    Grachev, E.
    Dubkov, M.
    [J]. RECENT TRENDS IN CHARGED PARTICLE OPTICS AND SURFACE PHYSICS INSTRUMENTATION, 2016, : 72 - 73
  • [6] A Microfocus X-Ray Tube with Rotating Anode
    Podymsky A.A.
    Potrakhov N.N.
    [J]. Biomedical Engineering, 2014, 48 (02) : 78 - 80
  • [7] MODIFICATION OF A COSSLETT-NIXON MICROFOCUS X-RAY TUBE FOR USE AS AN X-RAY MICROANALYZER
    DILS, RR
    ZEITZ, L
    HUGGINS, RA
    KEITH, DL
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1961, 32 (09): : 1040 - &
  • [8] A microfocus X-ray tube used with focusing collimators
    Arndt, UW
    Long, JVP
    Duncumb, P
    [J]. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1998, 31 (pt 6) : 936 - 944
  • [9] Evaluation of a microtomography system with an X-ray microfocus tube
    Lopes, RT
    Rodrigues, JL
    De Assis, JT
    De Jesus, EFO
    De Oliveira, LF
    [J]. APPLIED RADIATION AND ISOTOPES, 1997, 48 (10-12) : 1437 - 1442
  • [10] Optimization of transmission-type anode target in microfocus X-ray tube
    Zheng, Lei
    Liu, Huarong
    Sun, Buliang
    Wang, Junting
    Luo, Tingting
    Li, Yijing
    [J]. Zhenkong Kexue yu Jishu Xuebao/Journal of Vacuum Science and Technology, 2015, 35 (12): : 1443 - 1448