摘要
The Vattenfall Hydropower GmbH & Co. KG operates in Geesthacht a pump-storage hydropower plant (PSP). As a lower basin the Elbe River is used, providing process water for the PSP. For estimating the hazard for upstream migrating fish, caused by the PSP by entrainment in the pumps, the acoustic telemetry was used. For that specimens of different species were tagged using acoustics transmitters. Individual swimming patterns has been tracked by installing 21 hydrophones in the Elbe River and lower basin of the PSP. Only a few of overall 262 redetected fish swam into the lower basin of the PSP and almost all of them returned to the Elbe River. Only the fate of three fish could not be clarified, leading to an estimated maximum damage risk for migrating fish of 1.1 %.
引用
收藏
页码:28 / 33
页数:6
相关论文
共 50 条
  • [21] Development of small hydropower plant utilizing pumped storage power plant's dam
    Watabe, H.
    Arai, N.
    DAMS AND RESERVOIRS UNDER CHANGING CHALLENGES, 2011, : 211 - 218
  • [22] Energy storage using pumped storage hydropower
    Canter, Neil
    Tribology and Lubrication Technology, 2024, 80 (02): : 12 - 13
  • [23] Quantifying the revenue gain of operating a cascade hydropower plant system as a pumped-storage hydropower system
    Ak, Mumtaz
    Kentel, Elcin
    Savasaneril, Secil
    RENEWABLE ENERGY, 2019, 139 : 739 - 752
  • [24] CFD as a Decision Tool for Pumped Storage Hydropower Plant Flow Measurement Method
    Soucek, Jiri
    Nowak, Petr
    Kantor, Martin
    Vesely, Radek
    WATER, 2023, 15 (04)
  • [25] Dynamic analysis of a pumped-storage hydropower plant with random power load
    Zhang, Hao
    Chen, Diyi
    Xu, Beibei
    Patelli, Edoardo
    Tolo, Silvia
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2018, 100 : 524 - 533
  • [26] Active NPC Converter for Variable Speed Operation of Pumped Storage Hydropower Plant
    Tiwari, Raghbendra
    Nilsen, Roy
    Nysveen, Arne
    IECON 2020: THE 46TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2020, : 1211 - 1216
  • [27] Development of WHED Method to Study Operational Stability of Typical Transitions in a Hydropower Plant and a Pumped Storage Plant
    Mao, Xiuli
    Wen, Guoqing
    Wang, Yuchuan
    Hu, Jiaren
    Gan, Xuetao
    Zhong, Pengju
    ENERGIES, 2025, 18 (06)
  • [28] Hydraulic model study of the intake-outlet of a pumped-storage hydropower plant
    Bermudez, Maria
    Cea, Luis
    Puertas, Jeronimo
    Conde, Andre
    Martin, Ana
    Baztan, Javier
    ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2017, 11 (01) : 483 - 495
  • [29] The European Fish Hazard Index - An assessment tool for screening hazard of hydropower plants for fish
    van Treeck, Ruben
    Radinger, Johannes
    Noble, Richard A. A.
    Geiger, Franz
    Wolter, Christian
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 43
  • [30] Economic and policy considerations regarding hydropower and migratory fish
    Nieminen, Emmi
    Hyytiainen, Kari
    Lindroos, Marko
    FISH AND FISHERIES, 2017, 18 (01) : 54 - 78