Utility of a single beta HCG measurement to evaluate for absence of ectopic pregnancy

被引:12
|
作者
Marill, KA [1 ]
Ingmire, TE [1 ]
Nelson, BK [1 ]
机构
[1] Texas Tech Univ, Dept Emergency Med, El Paso, TX 79905 USA
来源
JOURNAL OF EMERGENCY MEDICINE | 1999年 / 17卷 / 03期
关键词
pregnancy; ectopic; gonadotropins; chorionic; pregnancy trimester; first; tubal;
D O I
10.1016/S0736-4679(99)00007-4
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The objectives of this study were to determine the optimal cutoff value (CV) and utility of a single serum beta human chorionic gonadotropin hormone (HCG) level in assessing the likelihood of ectopic pregnancy (ECP). A retrospective chart review was performed at an urban county hospital. The optimal CV was determined by comparing all available patients diagnosed with ECP and patients diagnosed with threatened abortion (TA) in the Emergency Department (ED) who subsequently delivered a baby at the same hospital, The utility of the test was assessed in a group of all known patients who presented to the ED with lower abdominal or pelvic pain or vaginal bleeding beta een 6 and 13 weeks estimated gestational age (EGA), There were 212 ECPs with measured HCGs, Only nine presented after 13 weeks EGA, The mean HCG value was 5,378 mIU/mL, There was no significant correlation between HCG and EGA. There were 132 TAs with measured HCGs who subsequently delivered. Only four TAs presented before 6 weeks EGA. Regarding the TA patients who presented between 6 and 13 weeks EGA, there were 81 with a mean HCG of 83,810 mIU/mL. Between 6 and 13 weeks EGA, HCG was not significantly correlated with EGA, The entire ECP group was compared with the TA group with 6-13 week EGA. A receiver operating characteristic curve with nine HCG cutoff values was constructed. Clinically the optimal CV was 40K. At this level, a test for the condition "absence of ECP" hall a specificity of 99%, and only two of 212 ECPs in our group would test false-positive with an HCG value over 40K. When the test was applied to a group of 175 women who presented with pain or bleeding between 6 and 13 weeks EGA, the sensitivity and positive predictive value for an intrauterine pregnancy were 24% and 99.9%, respectively. However, if this test was applied to all patients regardless of clinical findings, and then an ultrasound (U/S) algorithm was applied to the patients who had an HCG of less than 40K, it would predictably increase the rate of ECPs falsely identified as intrauterine pregnancies (IUPs) by 1%, regardless of the false-positive rate of the U/S algorithm itself. Given the potential morbidity and mortality of undiagnosed ectopic pregnancy, ultimately neither this test nor any other that is less than 100% specific for IUP can be recommended instead of an initial U/S evaluation for patients who present at risk for ECP. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:419 / 426
页数:8
相关论文
共 50 条
  • [21] URINE HCG BETA-SUBUNIT CORE FRAGMENT, A SENSITIVE TEST FOR ECTOPIC PREGNANCY
    COLE, LA
    KARDANA, A
    SEIFER, DB
    BOHLER, HCL
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1994, 78 (02): : 497 - 499
  • [22] DIAGNOSIS OF EARLY ECTOPIC PREGNANCY BY MEASUREMENT OF THE MATERNAL SERUM TO CUL-DE-SAC FLUID BETA-HCG RATIO
    HINNEY, B
    BERTAGNOLI, C
    TOBLERSOMMER, M
    OSMERS, R
    WUTTKE, W
    KUHN, W
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1995, 5 (04) : 260 - 266
  • [23] RAPID MODIFICATION OF BETA-HCG RADIOIMMUNOASSAY - USE AS AN AID IN DIAGNOSIS OF ECTOPIC PREGNANCY
    RASOR, JL
    BRAUNSTEIN, GD
    OBSTETRICS AND GYNECOLOGY, 1977, 50 (05): : 553 - 558
  • [24] Ruptured ectopic pregnancy with undetectable beta-hCG levels coexisting with acute appendicitis
    Bozoklu, S
    Bozoklu, E
    Ciftci, A
    Coskun, T
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1997, 76 (02) : 181 - 182
  • [25] Ectopic Pregnancy With Low Beta-Human Chorionic Gonadotropin (HCG) Managed With Methotrexate and to
    Prabhakaran, Madhumitha
    Beesetty, Anju
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (10)
  • [26] BETA-HCG CONCENTRATION IN PERITONEAL-FLUID AND SERUM IN ECTOPIC AND INTRAUTERINE PREGNANCY
    OETTINGER, M
    ODEH, M
    TARAZOVA, L
    SNITKOVSKY, T
    OPHIR, E
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1995, 74 (03) : 212 - 215
  • [27] THE CONTRIBUTION OF HCG ASSAY IN THE DIAGNOSIS OF ECTOPIC PREGNANCY
    KERBRAT, G
    PAPIERNIK, E
    ROGER, M
    CONTRACEPTION FERTILITE SEXUALITE, 1984, 12 (04): : 585 - 589
  • [28] THE USE OF HCG DETERMINATIONS IN THE DIAGNOSIS OF ECTOPIC PREGNANCY
    STANDEFER, JC
    MATTOX, JH
    CLINICAL CHEMISTRY, 1983, 29 (06) : 1267 - 1267
  • [29] PLASMA HCG AND ULTRASOUND IN SUSPECTED ECTOPIC PREGNANCY
    JOUPPILA, P
    TAPANAINEN, J
    HUHTANIEMI, I
    EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1980, 10 (01): : 3 - 12
  • [30] BORDERLINE SERUM HCG IN A PATIENT WITH ECTOPIC PREGNANCY
    SIMSIR, A
    BOCK, J
    LABORATORY MEDICINE, 1994, 25 (11) : 705 - 706