Quantitative determination and validation of 17 cannabinoids in cannabis and hemp using liquid chromatography-tandem mass spectrometry

被引:51
|
作者
McRae, Garnet [1 ]
Melanson, Jeremy E. [1 ]
机构
[1] Natl Res Council Canada, Metrol, 1200 Montreal Rd, Ottawa, ON K1A 0R6, Canada
关键词
Cannabinoids; Cannabis; Hemp; Liquid chromatography-mass spectrometry; Validation; WHOLE-BLOOD; QUANTIFICATION; HPLC/DAD; PLANTS; URINE; SEED; THC;
D O I
10.1007/s00216-020-02862-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The increase in production of cannabis for medical and recreational purposes in recent years has led to a corresponding increase in laboratories performing cannabinoid analysis of cannabis and hemp. We have developed and validated a quantitative liquid chromatography-tandem mass spectrometry (LC-MS/MS) method that is simple, reliable, specific, and accurate for the analysis of 17 cannabinoids in cannabis and hemp. Liquid-solid sample extraction coupled with dilution into a calibration ranges from 10 to 10,000 ng/mL and LC-MS/MS analysis provides quantification of samples ranging from 0.002 to 200 mg/g (0.0002 to 20.0%) in matrix. Linearity of calibration curves in methanol was demonstrated with regressionr(2) >= 0.99. Within-batch precision (0.5 to 6.5%) and accuracy (91.4 to 108.0%) and between-batch precision (0.9 to 5.1%) and accuracy (91.5 to 107.5%) were demonstrated for quality control (QC) samples in methanol. Within-batch precision (0.2 to 3.6%) and accuracy (1.4 to 6.1%) and between-batch precision (1.4 to 6.1 %) and accuracy (90.2 to 110.3%) were also evaluated with a candidate cannabis certified reference material (CRM). Repeatability (1.5 to 12.4% RSD) and intermediate precision (2.2 to 12.8% RSD) were demonstrated via analysis of seven cannabis samples with HorRat values ranging from 0.3 to 3.1. The method provides enhanced detection limits coupled with a large quantitative range for 17 cannabinoids in plant material. It is suitable for a wide range of applications including routine analysis for delta-9-tetrahydrocannabinol (Delta(9)-THC), delta-9-tetrahydrocannabinolic acid (Delta(9)-THCA), cannabidiol (CBD), cannabidiolic acid (CBDA), and cannabinol (CBN) as well as more advanced interrogation of samples for both major and minor cannabinoids.
引用
收藏
页码:7381 / 7393
页数:13
相关论文
共 50 条
  • [21] Determination of alprazolam by liquid chromatography-tandem mass spectrometry
    Svinarov, DA
    Kotzev, C
    Kassabova, LV
    [J]. CLINICA CHIMICA ACTA, 2005, 355 : S421 - S421
  • [22] Determination of cyclosporine in saliva using liquid chromatography-tandem mass spectrometry
    Mendonza, A
    Gohh, R
    Akhlaghi, F
    [J]. THERAPEUTIC DRUG MONITORING, 2004, 26 (05) : 569 - 575
  • [23] Determination of protease inhibitors using liquid chromatography-tandem mass spectrometry
    Frerichs, VA
    DiFrancesco, R
    Morse, GD
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 787 (02): : 393 - 403
  • [24] Method Validation for Quantitative Analysis of Metribuzin in Wheat by Liquid Chromatography-Tandem Mass Spectrometry
    Hazra, Dipak Kumar
    Purkait, Aloke
    Raghuwanshi, Durgesh
    Murthy, K. Sri Rama
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2021, 59 (01) : 47 - 54
  • [25] Simultaneous determination of 17 antiretroviral drugs in human plasma for quantitative analysis with liquid chromatography-tandem mass spectrometry
    Jung, Byung Hwa
    Rezk, Naser L.
    Bridges, Arlene S.
    Corbett, Amanda H.
    Kashuba, Angela D. M.
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (10) : 1095 - 1104
  • [26] Potency analysis of twelve cannabinoids in industrial hemp via ultrahigh-performance liquid chromatography-tandem mass spectrometry
    Cai, Youxi
    Zhang, Ruiting
    Zhang, Hao
    Li, Xiaolei
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2024, 38 (18)
  • [27] Quantification and Validation of Ertapenem Using a Liquid Chromatography-Tandem Mass Spectrometry Method
    van Rijn, S. P.
    Wessels, A. M. A.
    Greijdanus, B.
    Touw, D. J.
    Alffenaar, J. W. C.
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2014, 58 (06) : 3481 - 3484
  • [28] Development and validation of a method for determination of corticosteroids in pig fat using liquid chromatography-tandem mass spectrometry
    Toelgyesi, Adam
    Sharma, Virender K.
    Fekete, Jeno
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (5-6): : 403 - 410
  • [29] Quantitative determination of erythrocyte folate vitamer distribution by liquid chromatography-tandem mass spectrometry
    Smith, DEC
    Kok, RM
    Teerlink, T
    Jakobs, C
    Smulders, YM
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (04) : 450 - 459
  • [30] Quantitative determination of spinosin in rat plasma by liquid chromatography-tandem mass spectrometry method
    Li, Yujuan
    Yao, Meicun
    Cheng, Shan
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (04) : 1169 - 1173