A comprehensive dosimetric study of Monte Carlo and pencil-beam algorithms on intensity-modulated proton therapy for breast cancer

被引:25
|
作者
Liang, Xiaoying [1 ]
Li, Zuofeng [1 ]
Zheng, Dandan [2 ]
Bradley, Julie A. [1 ]
Rutenberg, Michael [1 ]
Mendenhall, Nancy [1 ]
机构
[1] Univ Florida, Dept Radiat Oncol, Coll Med, Gainesville, FL 32611 USA
[2] Univ Nebraska Med Ctr, Dept Radiat Oncol, Omaha, NE USA
来源
关键词
breast cancer; dose algorithms; IMPT; DOSE CALCULATIONS; ACCURACY;
D O I
10.1002/acm2.12497
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PB algorithms are commonly used for proton therapy. Previously reported limitations of the PB algorithm for proton therapy are mainly focused on high-density gradients and small-field dosimetry, the effect of PB algorithms on intensity-modulated proton therapy (IMPT) for breast cancer has yet to be illuminated. In this study, we examined 20 patients with breast cancer and systematically investigated the dosimetric impact of MC and PB algorithms on IMPT. Four plans were generated for each patient: (a) a PB plan that optimized and computed the final dose using a PB algorithm; (b) a MC-recomputed plan that recomputed the final dose of the PB plan using a MC algorithm; (c) a MC-renormalized plan that renormalized the MC-recomputed plan to restore the target coverage; and (d) a MC-optimized plan that optimized and computed the final dose using a MC algorithm. The DVH on CTVs and on organ-at-risks (OARs) from each plan were studied. The Mann Whitney U-test was used for testing the differences between any two types of plans. We found that PB algorithms significantly overestimated the target dose in breast IMPT plans. The median value of the CTV D-99%, D-95%, and D-mean, dropped by 3.7%, 3.4%, and 2.1%, respectively, of the prescription dose in the MC-recomputed plans compared with the PB plans. The magnitude of the target dose overestimation by the PB algorithm was higher for the breast CTV than for the chest wall CTV. In the MC-renormalized plans, the target dose coverage was comparable with the original PB plans, but renormalization led to a significant increase in target hot spots as well as skin dose. The MC-optimized plans led to sufficient target dose coverage, acceptable target hot spots, and good sparing of skin and other OARs. Utilizing the MC algorithm for both plan optimization and final dose computation in breast IMPT treatment planning is therefore desirable.
引用
收藏
页码:128 / 136
页数:9
相关论文
共 50 条
  • [1] Radiobiological and dosimetric impact of RayStation pencil beam and Monte Carlo algorithms on intensity-modulated proton therapy breast cancer plans
    Rana, Suresh
    Greco, Kevin
    Samuel, E. James Jebaseelan
    Bennouna, Jaafar
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (08): : 36 - 46
  • [2] Pencil-beam scanning proton therapy for anal cancer: a dosimetric comparison with intensity-modulated radiotherapy
    Ojerholm, Eric
    Kirk, Maura L.
    Thompson, Reid F.
    Zhai, Huifang
    Metz, James M.
    Both, Stefan
    Ben-Josef, Edgar
    Plastaras, John P.
    [J]. ACTA ONCOLOGICA, 2015, 54 (08) : 1209 - 1217
  • [3] Optimal minimum MU for intensity-modulated proton therapy with pencil-beam scanning proton beams
    Yi, Byongyong
    Mossahebi, Sina
    Jatczak, Jenna
    Mundis, Michelle
    Houser, Thomas
    Alicia, David
    Han, Dong
    Gonzalez, Rosette
    Olis, Stephen
    Zakhary, Mark
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024,
  • [4] A pencil beam algorithm for intensity modulated proton therapy and its validation with Monte Carlo
    Soukup, M
    Fippel, M
    Alber, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S65 - S65
  • [5] A pencil beam algorithm for intensity modulated proton therapy derived from Monte Carlo simulations
    Soukup, M
    Fippel, M
    Alber, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (21): : 5089 - 5104
  • [6] Dosimetric uncertainties in pencil beam proton therapy for breast cancer
    Tommasino, F.
    Lorentini, S.
    Schwarz, M.
    Fellin, F.
    Farace, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S68 - S68
  • [7] An Automatic Beam Model Commissioning Method for Monte Carlo Simulations in Pencil-Beam Scanning Proton Therapy
    Qin, N.
    Shen, C.
    Tian, Z.
    Jiang, S.
    Jia, X.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3335 - 3335
  • [8] Monte Carlo vs. pencil-beam dose calculation for uncertainty estimation in proton therapy
    Wahl, N.
    Wieser, H.
    Burigo, L.
    Bangert, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S731 - S731
  • [9] Dosimetric advantages of proton beam therapy compared to intensity-modulated radiation therapy for retroperitoneal chordoma
    Yu, Nathan Y.
    Vora, Sujay A.
    [J]. RARE TUMORS, 2019, 11
  • [10] Dose differences in intensity-modulated radiotherapy plans calculated with pencil beam and Monte Carlo for lung SBRT
    Liu, Han
    Zhuang, Tingliang
    Stephans, Kevin
    Videtic, Gregory
    Raithel, Stephen
    Djemil, Toufik
    Xia, Ping
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (06): : 91 - 99