Development of a flexible optical fiber based high resolution integrated PET/MRI system

被引:25
|
作者
Yamamoto, Seiichi [1 ]
Watabe, Hiroshi [2 ]
Kanai, Yasukazu [2 ]
Watabe, Tadashi [3 ]
Aoki, Masaaki [4 ]
Sugiyama, Eiji [4 ]
Kato, Katsuhiko [1 ]
Hatazawa, Jun [2 ,3 ]
机构
[1] Nagoya Univ, Grad Sch Med, Dept Radiol & Med Lab Sci, Nagoya, Aichi 4618673, Japan
[2] Osaka Univ, Grad Sch Med, Dept Mol Imaging Med, Suita, Osaka 5650871, Japan
[3] Osaka Univ, Grad Sch Med, Dept Nucl Med & Tracer Kinet, Suita, Osaka 5650871, Japan
[4] Neomax Engn, Takasaki, Gunma 3702115, Japan
关键词
PET/MRI; integrated; optical fiber; high resolution; SIMULTANEOUS PET; MRI; MULTISLICE; DETECTOR; ACQUISITION; SCANNER;
D O I
10.1118/1.4757911
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The simultaneous measurement of PET and magnetic resonance imaging (MRI) is an emerging field for molecular imaging research. Although optical fiber based PET/MRI systems have advantages on less interference between PET and MRI, there is a drawback in reducing the scintillation light due to the fiber. To reduce the problem, the authors newly developed flexible optical fiber bundle based block detectors and employed them for a high resolution integrated PET/MRI system. Methods: The flexible optical fiber bundle used 0.5 mm diameter, 80 cm long double clad fibers which have dual 12 mm x 24 mm rectangular inputs and a single 24 mm x 24 mm rectangular output. In the input surface, LGSO scintillators of 0.025 mol.% (decay time: similar to 31 ns: 0.9 mm x 1.3 mm x 5 mm) and 0.75 mol.% (decay time: similar to 46 ns: 0.9 mm x 1.3 mm x 6 mm) were optically coupled in depth direction to form depth-of-interaction detector, arranged in 11 x 13 matrix and optically coupled to the fiber bundle. The two inputs of the bundle are bent for 90 degrees, bound to one, and are optically coupled to a Hamamatsu 1-in. square position sensitive photomultiplier tube. Results: Light loss due to the fiber bundle could be reduced and the performance of the block detectors was improved. Eight optical fiber based block detectors (16 LGSO blocks) were arranged in a 56 mm diameter ring to form a PET system. Spatial resolution and sensitivity were 1.2 mm full-width at half-maximum and 1.2% at the central field-of-view, respectively. Sensitivity change was less than 1% for 2 degrees C temperature changes. This PET system was integrated with a 0.3 T permanent magnet MRI system which has 17 cm diameter hole at the yoke area for insertion of the PET detector ring. There was no observable interference between PET and MRI. Simultaneous imaging of PET and MRI was successfully performed for small animal studies. Conclusions: The authors confirmed that the developed high resolution PET/MRI system is promising for molecular imaging research. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4757911]
引用
收藏
页码:6660 / 6671
页数:12
相关论文
共 50 条
  • [1] Development of a flexible optical fiber based high resolution integrated PET/MRI system: iPET/MRI II
    Yamamoto, Seiichi
    Aoki, Masaaki
    Sugiyama, Eiji
    Watabe, Hiroshi
    Watabe, Tadashi
    Kanai, Yasukazu
    Imaizumi, Masao
    Shimosegawa, Eku
    Hatazawa, Jun
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [2] A flexible optical fiber based LGSO DOI block detector for a high resolution integrated PET/MRI system: iPET/MRI-II
    Yamamoto, Seiichi
    Aoki, Masaaki
    Sugiyama, Eiji
    Shimosegawa, Eku
    Hatazawa, Jun
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [3] Simultaneous imaging using Si-PM-based PET and MRI for development of an integrated PET/MRI system
    Yamamoto, Seiichi
    Watabe, Tadashi
    Watabe, Hiroshi
    Aoki, Masaaki
    Sugiyama, Eiji
    Imaizumi, Masao
    Kanai, Yasukazu
    Shimosegawa, Eku
    Hatazawa, Jun
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (02): : N1 - N13
  • [4] Development of an integrated PET/MRI (iPET/MRI) system for small animals
    Yamamoto, Seiichi
    Imaizumi, Masao
    Tatsumi, Mitsuaki
    Kanai, Yasukazu
    Higuchi, Ichiro
    Kawakami, Makoto
    Aoki, Masaaki
    Shimosegawa, Eku
    Hatazawa, Jun
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [5] Design and Development of a High Resolution Onboard PET for Integrated PET/CT Animal Irradiator
    Shao, Y.
    Zhong, Y.
    Cheng, X.
    Wang, J.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)
  • [6] A High Spatial Resolution Distributed Optical Fiber Grating Sensing System Based on OFDR
    Dong Ke
    Xiong Yuchuan
    Wen Hongqiao
    Tong Xinlin
    Zhang Cui
    Deng Chengwei
    [J]. AOPC 2017: FIBER OPTIC SENSING AND OPTICAL COMMUNICATIONS, 2017, 10464
  • [7] PET/MRI IN ALZHEIMER'S DISEASE: ADVANCES IN THE INTEGRATED PET/MRI SYSTEM
    Zhu, Ye
    Yang, Yun
    Qu, Xinhui
    Yang, Ping
    Jiang, Lingxia
    He, Min
    [J]. ACTA MEDICA MEDITERRANEA, 2022, 38 (01): : 495 - 502
  • [8] Flexible metal grating based optical fiber probe for photonic integrated circuits
    Scheerlinck, Stijn
    Taillaert, Dirk
    Van Thourhout, Dries
    Baets, Roel
    [J]. APPLIED PHYSICS LETTERS, 2008, 92 (03)
  • [9] Preliminary evaluation of a monolithic detector module for integrated PET/MRI scanner with high spatial resolution
    Pani, R.
    Gonzalez, A. J.
    Bettiol, M.
    Fabbri, A.
    Cinti, M. N.
    Preziosi, E.
    Borrazzo, C.
    Conde, P.
    Pellegrini, R.
    Di Castro, E.
    Majewski, S.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10
  • [10] Development of a Si-PM-based high-resolution PET system for small animals
    Yamamoto, Seiichi
    Imaizumi, Masao
    Watabe, Tadashi
    Watabe, Hiroshi
    Kanai, Yasukazu
    Shimosegawa, Eku
    Hatazawa, Jun
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (19): : 5817 - 5831