Carry-Over Effects of the Membrane Interface Probe

被引:10
|
作者
Bumberger, Jan [1 ]
Radny, Dirk [2 ]
Berndsen, Andreas [3 ]
Goblirsch, Tobias [1 ]
Flachowsky, Johannes [1 ]
Dietrich, Peter [1 ]
机构
[1] UFZ Helmholtz Ctr Environm Res, Helmholtz Ctr Environm Res, Dept Monitoring & Explorat Technol, D-04318 Leipzig, Germany
[2] Tech Univ Berlin, Dept Hydrogeol, D-13355 Berlin, Germany
[3] MPBF Mess & Probenahmetech, D-72401 Haigerloch Gruol, Germany
关键词
D O I
10.1111/j.1745-6584.2011.00879.x
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
The membrane interface probe (MIP) is widely used to characterize the subsurface distribution of volatile organic compounds (VOCs). One problem that arises during MIP application is that disproportionately high MIP signals are obtained after passing source zones which contain mobile or residual phases. This serious problem occurs because of a carry-over effect, in particular caused by compound-specific retention times in the conventional unheated transfer line, commonly used during such an investigation. The objective of this study was to perform a qualitative methodical field evaluation of the carry-over effect of a conventional MIP system with a conventional unheated transfer line. This was achieved by coupling a mobile mass spectrometer to the MIP device. Results obtained were then further compared with those achieved using a laser induced fluorescence (LIF) system. Because of this coupling, time- and depth-dependent signals for different substances became known. Field evaluation data obtained showed complex superpositions of compounds with MIP system results. As a result of this superposition, MIP signals from the saturated zone beneath the source zone (zone with free and/or residual phase) are blurred and are therefore not representative of particular depths. However, utilizing multidirectional probing alongside conventional MIP probing (forwards and backwards), it was possible to detect the upper and lower phase boundary of the source zone. These MIP results correlated excellently with the LIF results. An important conclusion that can be drawn from the field investigation is that coupling a mobile mass spectrometer to the MIP system enables advanced MIP signal interpretation to be successfully achieved.
引用
收藏
页码:578 / 584
页数:7
相关论文
共 50 条
  • [1] A Triggered Depth-Dependent Sampling System to Overcome the Carry-Over Effects of the Membrane Interface Probe
    Bumberger, Jan
    Peisker, Kilian
    Reiche, Nils
    Radny, Dirk
    Dietrich, Peter
    [J]. GROUND WATER MONITORING AND REMEDIATION, 2016, 36 (03): : 54 - 61
  • [2] EFFECTS OF ADVERTISING CARRY-OVER
    CASE, KE
    SHAMBLIN, JE
    [J]. JOURNAL OF ADVERTISING RESEARCH, 1972, 12 (03) : 37 - 40
  • [3] CARRY-OVER EFFECTS OF MARIJUANA
    MORGAN, JP
    [J]. AMERICAN JOURNAL OF PSYCHIATRY, 1987, 144 (02): : 259 - 260
  • [4] On the evolution of carry-over effects
    Moore, Michael P.
    Martin, Ryan A.
    [J]. JOURNAL OF ANIMAL ECOLOGY, 2019, 88 (12) : 1832 - 1844
  • [5] CARRY-OVER EFFECTS OF SMALL CLASSES
    FINN, JD
    FULTON, D
    ZAHARIAS, J
    NYE, BA
    [J]. PEABODY JOURNAL OF EDUCATION, 1989, 67 (01): : 75 - 84
  • [6] EFFECTS OF ADVERTISING CARRY-OVER - REPLY
    CASE, KE
    SHAMBLIN, JE
    [J]. JOURNAL OF ADVERTISING RESEARCH, 1975, 15 (03) : 45 - 45
  • [7] Balancing carry-over effects in tournaments
    Anderson, I
    [J]. COMBINATORIAL DESIGNS AND THEIR APPLICATIONS, 1999, 403 : 1 - 16
  • [8] CARRY-OVER EFFECTS OF MARIJUANA - REPLY
    YESAVAGE, JA
    [J]. AMERICAN JOURNAL OF PSYCHIATRY, 1987, 144 (02): : 260 - 260
  • [9] CARRY-OVER EFFECTS OF TURKEY STARTER DIETS
    WARNICK, RE
    [J]. POULTRY SCIENCE, 1979, 58 (04) : 1120 - 1121
  • [10] DESIGNS FOR SEQUENCES OF TREATMENTS WITH CARRY-OVER EFFECTS
    ATKINSON, GF
    [J]. BIOMETRICS, 1966, 22 (02) : 292 - &