Diagnostic Reference Levels for nuclear medicine imaging in Austria: A nationwide survey of used dose levels for adult patients

被引:6
|
作者
Wachabauer, David [1 ]
Beyer, Thomas [2 ,3 ]
Ditto, Manfred [4 ]
Gallowitsch, Hans-Juergen [3 ,5 ]
Hinterreiter, Michael [6 ]
Ibi, Bettina [7 ,8 ]
Malle, Phillipp [9 ,10 ]
Mirzaei, Siroos [3 ]
Smetana, Florian [5 ,8 ]
Staudenherz, Anton [11 ,12 ]
Warwitz, Boris [8 ,13 ]
Zettinig, Georg [14 ,15 ]
Rausch, Ivo [2 ,12 ,16 ]
机构
[1] Gesundheit Osterreich GmbH GOG, Austrian Natl Publ Hlth Inst, Vienna, Austria
[2] Med Univ Vienna, Ctr Med Phys & Biomed Engn, QIMP Team, Vienna, Austria
[3] Austrian Soc Nucl Med & Mol Biol OGNMB, Vienna, Austria
[4] Fed Minist Social Affairs Hlth Care & Consumer Pro, Vienna, Austria
[5] Klinikum Klagenfurt Worthersee, Dept Nucl Med & Endocrinol, Klagenfurt, Austria
[6] rtaustria Austrian Soc Radiol Technol, Wiener Neustadt, Austria
[7] Inst Hosp Phys, Clin Hietzing, Vienna, Austria
[8] Austrian Soc Med Phys OGMP, Vienna, Austria
[9] Klinikum Klagenfurt Worthersee, Inst Diagnost & Intervent Radiol, Klagenfurt, Austria
[10] Austrian Roentgen Soc, Vienna, Austria
[11] Karl Landsteiner Univ Hlth Sci, Dept Nucl Med, Univ Hosp St Poelten, Krems An Der Donau, Austria
[12] Austrian Soc Radiat Protect Med VMSO, Vienna, Austria
[13] Med Univ Innsbruck, Dept Nucl Med, Innsbruck, Austria
[14] Vienna Thyroid Ctr Schilddruesenpraxis Josefstadt, Vienna, Austria
[15] Austrian Med Assoc, Fed Working Grp Nucl Med, Vienna, Austria
[16] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Wahringer Gurtel 18-20-4L, A-1090 Vienna, Austria
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2022年 / 32卷 / 03期
关键词
Radiation Protection; Nuclear medicine; Diagnostic reference levels; GUIDELINE; EANM;
D O I
10.1016/j.zemedi.2021.11.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess dose levels in routine nuclear medicine (NUC) procedures in Austria as a prior to a legislative update of the National Diagnostic Reference Levels (NDRL).Method: As part of a nationwide survey of common NUC-examinations between June 2019 and November 2019, data sets were collected from 33 Austrian hospitals with NUC equipment. All hospitals were asked to report the NUC imaging devices in use (model, type, year of manufacture, detector material, collimators), the standard protocol parameters for selected examinations (standard activity, collimator, average acquisition time, reconstruction type, use of time-of-flight) and to report data from 10 representative examinations (e.g. injected activity, weight), incl. the most common NUC-examinations for planar imaging/SPECT and PET. Median/mean values for injected activity were calculated and compared to current Austrian and international NDRL. A Pearson correlation coefficient was computed comparing different variables.Results: In total, all 33 hospitals (100% response rate) reported data for this study for 60 SPECT devices, 21 PET/CT devices and 23 scintigraphy devices. Fixed activity values for scintigraphy/SPECT and PET were employed by about 90% and 56% of the hospitals, respectively. The most widely performed examinations for scintigraphy/SPECT are bone imaging, thyroid imaging, renal imaging (with MAG3/EC) and lung perfusion imaging (in 88% of the hospitals) and F-18 FDG-PET studies for oncology indications (in 100% of the hospitals). Significant correlations were found for patient weight and injected activity (scintigraphy/SPECT), use of iterative reconstruction and injected activity (PET) as well as size of field-of-view and injected activity (PET).Conclusions: The reported injected activity levels were comparable to those in other countries. However, for procedures for which NDRL exist, deviations in injected activities of >20% compared to the NDRL were found. These deviations are assumed to result mainly from advances in technology but also from deviations between NDRL and prescribed activities as given in the information leaflets of the radiopharmaceuticals.
引用
收藏
页码:283 / 295
页数:13
相关论文
共 50 条
  • [41] Diagnostic Reference Levels for Common CT Examinations: Results from a Statewide dose Survey
    Jusoh, Irwan Iskandar
    Abdullah, Kamarul Amin
    Ali, Mohd Hanafi
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (18) : 1417 - 1423
  • [42] OPTIMIZATION OF RADIATION DOSE IN CT IMAGING: ESTABLISHING THE INSTITUTIONAL DIAGNOSTIC REFERENCE LEVELS AND PATIENT DOSE AUDITING
    Razali, Mohd Amir Syahmi Mat
    Ahmad, Muhamad Zabidi
    Shuaib, Ibrahim Lutfi
    Osman, Noor Diyana
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (02) : 213 - 221
  • [43] Updated Australian diagnostic reference levels for adult CT
    Lee, Kam L.
    Beveridge, Toby
    Sanagou, Masoumeh
    Thomas, Peter
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2020, 67 (01) : 5 - 15
  • [44] A CONCEPTUAL FRAMEWORK FOR MANAGING RADIATION DOSE TO PATIENTS IN DIAGNOSTIC RADIOLOGY USING REFERENCE DOSE LEVELS
    Almen, Anja
    Bath, Magnus
    RADIATION PROTECTION DOSIMETRY, 2016, 169 (1-4) : 17 - 23
  • [45] Diagnostic Reference Levels in Nuclear Medicine: Development of a Simple Tool to Help Assessing the Portuguese Reality
    Martins, A.
    Almeida, P.
    Rodrigues, I.
    Carmona, S.
    Vieira, M. J.
    Pio, C.
    Martins, T.
    Alvernaz, A.
    Oliveira, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S386 - S386
  • [46] PROPOSALS FOR THE ESTABLISHMENT OF NATIONAL DIAGNOSTIC REFERENCE LEVELS FOR RADIOGRAPHY FOR ADULT PATIENTS BASED ON REGIONAL DOSE SURVEYS IN RUSSIAN FEDERATION
    Vodovatov, A. V.
    Balonov, Mikhail I.
    Golikov, V. Yu.
    Shatsky, I. G.
    Chipiga, L. A.
    Bernhardsson, C.
    RADIATION PROTECTION DOSIMETRY, 2017, 173 (1-3) : 223 - 232
  • [47] Local diagnostic reference levels and effective doses: single institution levels for interventional cardiology procedures for adult patients
    Kidon, Joanna
    Polaczek-Grelik, Kinga
    Wojciuch, Leszek
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2022, 28 (02): : 77 - 83
  • [48] Establishment of Provincial Diagnostic Reference Levels in Pediatric Imaging
    Tonkopi, E.
    O'Brien, K.
    MEDICAL PHYSICS, 2016, 43 (06) : 3716 - 3716
  • [49] Multicentre survey on patient dose in paediatric imaging and proposal for updated diagnostic reference levels for France. Part 2: plain radiography and diagnostic fluoroscopy
    David Célier
    Patrice Roch
    Cécile Etard
    Hubert Ducou Le Pointe
    Hervé J. Brisse
    European Radiology, 2020, 30 : 1182 - 1190
  • [50] Multicentre survey on patient dose in paediatric imaging and proposal for updated diagnostic reference levels for France. Part 2: plain radiography and diagnostic fluoroscopy
    Celier, David
    Roch, Patrice
    Etard, Cecile
    Ducou Le Pointe, Hubert
    Brisse, Herve J.
    EUROPEAN RADIOLOGY, 2020, 30 (02) : 1182 - 1190