Absolute physical thickness across the sample aperture is critical in determining the index of a refraction profile from the optical path length profile for gradient index (GRIN) materials, which have a designed inhomogeneous refractive index. Motivated by this application, instrumentation was established to measure the absolute thickness of samples with nominally plane-parallel surfaces up to 50 mm thick. The current system is capable of measuring absolute thickness with 120 nm (1 sigma) repeatability and submicrometer expanded measurement uncertainty. Beside GRIN materials, this method is also capable of measuring other inhomogeneous and opaque materials. (C) 2015 Optical Society of America
引用
收藏
页码:7693 / 7700
页数:8
相关论文
共 50 条
  • [21] A Spectral-Domain Low-Coherence Method for Measuring Composite Windshield Thickness
    Zhang, Tao
    Xia, Renbo
    Zhao, Jibin
    Sun, Yanyi
    Wu, Jiajun
    Fu, Shengpeng
    Chen, Yueling
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 14
  • [22] Measuring dispersion between two modes of an optical fibre using low-coherence spectral interferometry with a Michelson interferometer
    Hlubina, P
    [J]. JOURNAL OF MODERN OPTICS, 1999, 46 (11) : 1595 - 1604
  • [23] Absolute measurement of the fiber to waveguide distance during a coupling process by low-coherence interferometry
    Porte, H
    Elflein, W
    Ferriere, R
    [J]. MICRO-OPTICAL TECHNOLOGIES FOR MEASUREMENT, SENSORS, AND MICROSYSTEMS, 1996, 2783 : 98 - 104
  • [24] Axial-scanning low-coherence interferometer method for noncontact thickness measurement of biological samples
    Kim, Do-Hyun
    Song, Chul-Gyu
    Ilev, Ilko K.
    Kang, Jin U.
    [J]. APPLIED OPTICS, 2011, 50 (06) : 970 - 974
  • [25] The use of low-coherence interferometer for sugar content determination
    Jedrzejewska-Szczerska, M.
    [J]. SARATOV FALL MEETING 2014: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE XVI; LASER PHYSICS AND PHOTONICS XVI; AND COMPUTATIONAL BIOPHYSICS, 2015, 9448
  • [26] COMPACT IN-LINE INTERFEROMETER FOR LOW-COHERENCE REFLECTOMETRY
    SCHMITT, JM
    [J]. OPTICS LETTERS, 1995, 20 (04) : 419 - 421
  • [27] MEASUREMENT OF CORNEAL THICKNESS BY LOW-COHERENCE INTERFEROMETRY
    HITZENBERGER, CK
    [J]. APPLIED OPTICS, 1992, 31 (31): : 6637 - 6642
  • [28] Sensing applications of a low-coherence fibre-optic interferometer measuring the refractive index of air
    Murtry, SM
    Wright, JD
    Jackson, DA
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (01) : 69 - 74
  • [29] In-plane ESPI using an achromatic interferometer with low-coherence laser source
    Schajer, Gary S.
    Zhang, Yijian
    Melamed, Samuel
    [J]. OPTICS AND LASERS IN ENGINEERING, 2015, 67 : 116 - 121
  • [30] Comparison of optical low-coherence reflectometry and ultrasound pachymetry in measuring corneal graft thickness
    Gaujoux, Thomas
    Borderie, Vincent M.
    Yousfi, Hakim
    Bourcier, Tristan
    Touzeau, Olivier
    Laroche, Laurent
    [J]. CORNEA, 2007, 26 (02) : 185 - 189