Ultimate behavior of reinforced concrete cooling tower: Evaluation and comparison of design guidelines

被引:4
|
作者
Noh, HC [1 ]
Choi, CK
机构
[1] Columbia Univ, Dept Civil Engn & Engn Mech, New York, NY 10027 USA
[2] Korea Adv Inst Sci & Technol, Dept Civil & Environm Engn, Taejon 305701, South Korea
关键词
reinforced concrete cooling tower; nonlinearity; ultimate load; design guidelines; damage index;
D O I
10.12989/sem.2006.22.2.223
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Taking into account the geometrical and material nonlinearities, an ultimate behavior of reinforced concrete cooling tower shell in hyperbolic configuration is presented. The design wind pressures suggested in the guidelines of the US (ACI) and Germany (VGB), with or without the effect of internal suction, are employed in the analysis to examine the qualitative and quantitative characteristics of each design wind pressure. The geometrical nonlinearity is incorporated by the Green-Lagrange strain tensor. The nonlinear features of concrete, such as the nonlinear stress-strain relation in compression, the tensile cracking with the smeared crack model, an effect of tension stiffening, are taken into account. The biaxial stress state in concrete is represented by an improved work-hardening plasticity model. From the perspective of quality of wind pressures, the two guidelines are determined as highly correlated each other. Through the extensive analysis on the Niederaussem cooling tower in Germany, not only the ultimate load is determined but also the mechanism of failure, distribution of cracks, damage processes, stress redistributions, and mean crack width are examined.
引用
收藏
页码:223 / 240
页数:18
相关论文
共 50 条
  • [41] Tornado-induced collapse analysis of a super-large reinforced concrete cooling tower
    Chen, Xu
    Zhao, Lin
    Zhao, Shiyu
    Ke, Shitang
    Cao, Shuyang
    Ge, Yaojun
    ENGINEERING STRUCTURES, 2022, 269
  • [42] ULTIMATE STRENGTH DESIGN OF REINFORCED CONCRETE BEAMS UNDER TRIAXIAL COUPLES.
    Pandit, G.S.
    Venkappa, V.
    Indian Concrete Journal, 1979, 53 (05): : 132 - 135
  • [43] ULTIMATE STRENGTH DESIGN OF CIRCULAR REINFORCED-CONCRETE CROSS-SECTIONS
    FEKETE, G
    CIVIL ENGINEERING, 1973, 43 (11): : 80 - 81
  • [44] Serviceability and Ultimate Load Behavior of Concrete Beams Reinforced with Basalt Fiber-Reinforced Polymer Bars
    Ovitigala, Thilan
    Ibrahim, Mustapha A.
    Issa, Mohsen A.
    ACI STRUCTURAL JOURNAL, 2016, 113 (04) : 757 - 768
  • [45] Serviceability and Ultimate Load Behavior of Concrete Beams Reinforced with Basalt Fiber-Reinforced Polymer Bars
    Bischoff, Peter H.
    ACI STRUCTURAL JOURNAL, 2017, 114 (04) : 1067 - 1071
  • [46] Evaluation and modeling of ultimate bond strength of corroded reinforcement in reinforced concrete elements
    Esra Mete Güneyisi
    Kasım Mermerdaş
    Ayşegül Gültekin
    Materials and Structures, 2016, 49 : 3195 - 3215
  • [47] Evaluation and modeling of ultimate bond strength of corroded reinforcement in reinforced concrete elements
    Guneyisi, Esra Mete
    Mermerdas, Kasim
    Gultekin, Aysegul
    MATERIALS AND STRUCTURES, 2016, 49 (08) : 3195 - 3215
  • [48] Meggle Food Tower in Wasserburg - Design and Construction of an industrial facility in reinforced concrete
    Fuchs, Maximilian
    Schmied, Carola
    BETON- UND STAHLBETONBAU, 2012, 107 (07) : 484 - 489
  • [49] Comparison of the structural behavior of reinforced concrete and steel fiber reinforced concrete tunnel segmental joints
    Gong, Chenjie
    Ding, Wenqi
    Mosalam, Khalid M.
    Gunay, Selim
    Soga, Kenichi
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2017, 68 : 38 - 57
  • [50] EVALUATION OF VARYING METEOROLOGICAL PARAMETERS ON COOLING-TOWER PLUME BEHAVIOR
    TSAI, YJ
    HUANG, CH
    BULLETIN OF THE AMERICAN METEOROLOGICAL SOCIETY, 1974, 55 (05) : 527 - 527