Validation of viscoelastic coagulation tests during cardiopulmonary bypass

被引:42
|
作者
Ortmann, E. [1 ]
Rubino, A. [1 ]
Altemimi, B. [1 ]
Collier, T. [2 ]
Besser, M. W. [3 ]
Klein, A. A. [1 ]
机构
[1] Papworth Hosp, Dept Anaesthesia & Intens Care, Cambridge CB3 8RE, England
[2] London Sch Hyg & Trop Med, London WC1, England
[3] Cambridge Univ Hosp Fdn Trust, Addenbrookes Hosp, Dept Haematol, Cambridge, England
关键词
blood coagulation tests; cardiac surgical procedures; cardiopulmonary bypass; point-of-care systems; thromboelastography; CARDIAC SURGICAL-PATIENTS; ACTIVATED CLOTTING TIME; SURGERY-PATIENTS; THROMBOELASTOMETRY; HEPARIN; PROTAMINE; MANAGEMENT; ASSAYS; TRIAL;
D O I
10.1111/jth.12988
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundViscoelastic point-of-care tests such as thromboelastography (TEG) and rotational thromboelastometry (ROTEM) are increasingly used to guide hemostatic therapy after cardiac surgery. The aim of this study was to assess their clinical utility during cardiopulmonary bypass to predict postbypass coagulation status and to guide therapy. MethodsIn this prospective study, TEG and ROTEM tests were performed in 52 adult patients undergoing elective cardiac surgery at two time points: near the end of cardiopulmonary bypass and after heparin reversal with protamine. The 95% confidence intervals of the mean difference were compared with a prespecified clinically relevant limit of 20% of the value after protamine. ResultsBoth viscoelastic fibrinogen assays were well within the prespecified clinically relevant limit (79% of patients). The laboratory Clauss fibrinogen was much lower during cardiopulmonary bypass than after protamine (mean difference 1.2gL(-1), 95% CI 1.03-1.4, which was outside a clinically acceptable difference. For intrinsically activated tests, clotting times (CT) were different and outside the prespecified limit on TEG (mean difference -1.2 min, 95% CI -1.8 to -0.6) but not on ROTEM (mean difference 2.3 sec, 95% CI -8.6 to 13.2), while clot strength was well within the clinical limit on both devices (94% of patients). For extrinsically activated tests, clot strength on both TEG and ROTEM was within the pre-specified limit in 98% of patients. ConclusionsResults from TEG and ROTEM tests performed toward the end of cardiopulmonary bypass are similar to results after reversal of heparin. Amplitudes indicating clot strength were the most stable parameters across all tests, whereas CT showed more variability. In contrast, laboratory testing of fibrinogen using the Clauss assay was essentially invalid during cardiopulmonary bypass.
引用
下载
收藏
页码:1207 / 1216
页数:10
相关论文
共 50 条
  • [31] CHANGES IN THE COAGULATION AND FIBRINOLYTIC SYSTEMS DURING AND AFTER CARDIOPULMONARY BYPASS-SURGERY
    KONGSGAARD, UE
    SMITHERICHSEN, N
    GEIRAN, O
    BJORNSKAU, L
    THORACIC AND CARDIOVASCULAR SURGEON, 1989, 37 (03): : 158 - 162
  • [32] Retransfusion of pericardial blood does not trigger systemic coagulation during cardiopulmonary bypass
    van den Goor, Jeanette M.
    Nieuwland, Rienk
    Rutten, Peter M.
    Tijssen, Jan G.
    Hau, Chi
    Sturk, Augueste
    Eijsman, Leon
    de Mol, Bas A.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2007, 31 (06) : 1029 - 1036
  • [34] ALTERATIONS IN FIBRINOLYSIS AND COAGULATION ASSOCIATED WITH CARDIOPULMONARY BYPASS
    PORTER, JM
    SILVER, D
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1968, 56 (06): : 869 - &
  • [35] Coagulation and fibrinolytic protein kinetics in cardiopulmonary bypass
    Maryam Yavari
    Richard C. Becker
    Journal of Thrombosis and Thrombolysis, 2009, 27 : 95 - 104
  • [36] Coagulation and fibrinolytic protein kinetics in cardiopulmonary bypass
    Yavari, Maryam
    Becker, Richard C.
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2009, 27 (01) : 95 - 104
  • [37] A 2014 Update on Coagulation Management for Cardiopulmonary Bypass
    Thiele, Robert H.
    Raphael, Jacob
    SEMINARS IN CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2014, 18 (02) : 177 - 189
  • [38] Effect of ultrafiltration during cardiopulmonary bypass on viscoelastic profiles in cardiac surgery: Retrospective analysis
    Sohn, Kyo-Min
    Lee, Dong-Kyu
    Kim, Tae-Yop
    ANESTHESIA AND ANALGESIA, 2022, 135 (3S_SUPPL): : 8 - 8
  • [39] Changes in blood coagulation during and following cardiopulmonary bypass - Lack of correlation with clinical bleeding
    Gelb, AB
    Roth, RI
    Levin, J
    London, MJ
    Noall, RA
    Hauck, WW
    Cloutier, M
    Verrier, E
    Mangano, DT
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1996, 106 (01) : 87 - 99
  • [40] LOW ACTIVATED COAGULATION TIME DURING CARDIOPULMONARY BYPASS DOES NOT INCREASE POSTOPERATIVE BLEEDING
    METZ, S
    KEATS, AS
    ANNALS OF THORACIC SURGERY, 1990, 49 (03): : 440 - 444