Validation of viscoelastic coagulation tests during cardiopulmonary bypass

被引:42
|
作者
Ortmann, E. [1 ]
Rubino, A. [1 ]
Altemimi, B. [1 ]
Collier, T. [2 ]
Besser, M. W. [3 ]
Klein, A. A. [1 ]
机构
[1] Papworth Hosp, Dept Anaesthesia & Intens Care, Cambridge CB3 8RE, England
[2] London Sch Hyg & Trop Med, London WC1, England
[3] Cambridge Univ Hosp Fdn Trust, Addenbrookes Hosp, Dept Haematol, Cambridge, England
关键词
blood coagulation tests; cardiac surgical procedures; cardiopulmonary bypass; point-of-care systems; thromboelastography; CARDIAC SURGICAL-PATIENTS; ACTIVATED CLOTTING TIME; SURGERY-PATIENTS; THROMBOELASTOMETRY; HEPARIN; PROTAMINE; MANAGEMENT; ASSAYS; TRIAL;
D O I
10.1111/jth.12988
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundViscoelastic point-of-care tests such as thromboelastography (TEG) and rotational thromboelastometry (ROTEM) are increasingly used to guide hemostatic therapy after cardiac surgery. The aim of this study was to assess their clinical utility during cardiopulmonary bypass to predict postbypass coagulation status and to guide therapy. MethodsIn this prospective study, TEG and ROTEM tests were performed in 52 adult patients undergoing elective cardiac surgery at two time points: near the end of cardiopulmonary bypass and after heparin reversal with protamine. The 95% confidence intervals of the mean difference were compared with a prespecified clinically relevant limit of 20% of the value after protamine. ResultsBoth viscoelastic fibrinogen assays were well within the prespecified clinically relevant limit (79% of patients). The laboratory Clauss fibrinogen was much lower during cardiopulmonary bypass than after protamine (mean difference 1.2gL(-1), 95% CI 1.03-1.4, which was outside a clinically acceptable difference. For intrinsically activated tests, clotting times (CT) were different and outside the prespecified limit on TEG (mean difference -1.2 min, 95% CI -1.8 to -0.6) but not on ROTEM (mean difference 2.3 sec, 95% CI -8.6 to 13.2), while clot strength was well within the clinical limit on both devices (94% of patients). For extrinsically activated tests, clot strength on both TEG and ROTEM was within the pre-specified limit in 98% of patients. ConclusionsResults from TEG and ROTEM tests performed toward the end of cardiopulmonary bypass are similar to results after reversal of heparin. Amplitudes indicating clot strength were the most stable parameters across all tests, whereas CT showed more variability. In contrast, laboratory testing of fibrinogen using the Clauss assay was essentially invalid during cardiopulmonary bypass.
引用
下载
收藏
页码:1207 / 1216
页数:10
相关论文
共 50 条
  • [1] Validation of viscoelastic coagulation tests during cardiopulmonary bypass: comment
    Solomon, C.
    Fickenscher, K.
    Ormonde, L.
    Ranucci, M.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2015, 13 (12) : 2279 - 2281
  • [2] Validation of viscoelastic coagulation tests during cardiopulmonary bypass: reply
    Ortmann, E.
    Klein, A. A.
    Besser, M. W.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2015, 13 (12) : 2282 - 2282
  • [3] COMPARISON OF VISCOELASTIC MEASURES OF COAGULATION AFTER CARDIOPULMONARY BYPASS
    TUMAN, KJ
    SPIESS, BD
    MCCARTHY, RJ
    IVANKOVICH, AD
    ANESTHESIA AND ANALGESIA, 1989, 69 (01): : 69 - 75
  • [4] Management of coagulation during cardiopulmonary bypass
    O'Carroll-Kuehn, Britta U.
    Meeran, Hanif
    BJA EDUCATION, 2007, 7 (06) : 195 - 198
  • [5] Coagulation tests predict bleeding after cardiopulmonary bypass
    Nuttall, GA
    Oliver, WC
    Ereth, MH
    Santrach, PJ
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1997, 11 (07) : 815 - 823
  • [6] COAGULATION DEFECTS IN NEONATES DURING CARDIOPULMONARY BYPASS
    KERN, FH
    MORANA, NJ
    SEARS, JJ
    HICKEY, PR
    ANNALS OF THORACIC SURGERY, 1992, 54 (03): : 541 - 546
  • [7] COAGULATION DEFECTS IN NEONATES DURING CARDIOPULMONARY BYPASS
    JOBES, DR
    NICOLSON, SC
    STEVEN, JM
    MANNO, CS
    ANNALS OF THORACIC SURGERY, 1993, 55 (05): : 1283 - 1284
  • [8] Maintenance of homeostasis in coagulation during cardiopulmonary bypass
    Spiess, BD
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1999, 13 (04) : 2 - 5
  • [9] Coagulation tests during cardiopulmonary bypass correlate with blood loss in children undergoing cardiac surgery
    Williams, GD
    Bratton, SL
    Riley, EC
    Ramamoorthy, C
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1999, 13 (04) : 398 - 404
  • [10] Accelerated Intravascular Activation of Coagulation During Cardiopulmonary Bypass
    Parida, Satyen
    Patil, Pranit
    Prasad, Sreevathsa K. S.
    Jha, Ajay Kumar
    Panneerselvam, Sakthirajan
    INDIAN JOURNAL OF HEMATOLOGY AND BLOOD TRANSFUSION, 2020, 36 (03) : 585 - 587