Wide-Area Fault Location of Transmission Lines by Hybrid Synchronized/Unsynchronized Voltage Measurements

被引:31
|
作者
Dobakhshari, Ahmad Salehi [1 ]
机构
[1] Univ Guilan, Dept Elect Engn, Fac Engn, Rasht 4199613776, Iran
关键词
Bus impedance matrix; complex calculus; fault location; global positioning system; unsynchronized measurements; MULTITERMINAL DC SYSTEMS; PMU PLACEMENT; POWER-SYSTEMS; NETWORKS;
D O I
10.1109/TSG.2016.2601379
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Global positioning system (GPS) has been deployed in phasor measurement units and protective relays to provide synchronized measurements across the grid. Synchronized measurements, however, may not be available throughout the network either due to GPS signal loss (GSL) or basically lack of required infrastructure for synchronized sampling. This paper presents a novel method for wide-area fault location incorporating both synchronized and unsynchronized voltage measurements. Complex calculus is utilized to develop a system of equations based on phase angles of synchronized measurements and magnitudes of both synchronized and unsynchronized measurements. The distributed-parameter model of the transmission lines are considered and therefore the obtained results are also valid for long transmission lines. Moreover, the proposed formulation locates the fault irrespective of fault type. Electromagnetic transient simulations for WSCC 9-bus and a 22-bus sub-network of the IEEE 118-bus test system reveal that in the face of GSL, unsynchronized measurements significantly improve fault-location estimation when the synchronized measurements are sparse.
引用
收藏
页码:1869 / 1877
页数:9
相关论文
共 50 条
  • [31] Fault Location for Transmission Lines with Voltage and Current Measurements at One Bus
    Xiu, Wanjing
    Liao, Yuan
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2014, 15 (05) : 449 - 456
  • [32] Fault Location for Parallel Transmission Lines with Limited Voltage and Current Measurements
    Xiu, Wanjing
    Liao, Yuan
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2013, 14 (03): : 265 - 274
  • [33] An advanced wide-area fault detection and location technique for transmission lines considering optimal phasor measurement units allocation
    Abd el-Ghany, Hossam A.
    Soliman, Ismail A.
    ELGebaly, Ahmed E.
    ALEXANDRIA ENGINEERING JOURNAL, 2022, 61 (05) : 3971 - 3984
  • [34] Fault location technique for six phase transmission lines with unsynchronized phasors
    Stamp, JE
    Girgis, AA
    1999 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE, VOLS 1 & 2, 1999, : 663 - 667
  • [35] Fault Location on Series-Compensated Lines Using Unsynchronized Measurements
    Hussain, Shoaib
    Osman, Ahmed
    2013 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PES), 2013,
  • [36] Transmission line fault detection and location using Wide Area Measurements
    Das, Sayari
    Singh, Shiv P.
    Panigrahi, Bijaya K.
    ELECTRIC POWER SYSTEMS RESEARCH, 2017, 151 : 96 - 105
  • [37] A Novel Wide-area Fault Location Algorithm Based on Fault Model
    Ma, Jing
    Li, Jin-long
    Wang, Zeng-ping
    Yang, Qi-Xun
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [38] A novel wide-area fault location algorithm based on fault model
    Ma, Jing
    Li, Jin-Long
    Li, Jin-Hui
    Yang, Qi-Xun
    Wang, Zeng-Ping
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (20): : 74 - 78
  • [39] Unsynchronized parameter free fault location scheme for hybrid transmission line
    Hashemian, Seyed Mehran
    Hashemian, Seyed Nasrollah
    Gholipour, Mehdi
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 192
  • [40] Fault Location for Double-Circuit Transmission Lines using Travelling-Wave Theory with Unsynchronized Measurements
    Chaitanya, B. K.
    Andanapalli, Kumarraja
    Varma, Bh. R. K.
    2015 INTERNATIONAL CONFERENCE ON ENERGY, POWER AND ENVIRONMENT: TOWARDS SUSTAINABLE GROWTH (ICEPE), 2015,