摘要
The use of metal oxide nanoparticles for the development of cost-effective glucose biosensors has been receiving increased attention. Enzymatic and non-enzymatic glucose sensor using polyethylene glycol (PEG) grafted manganese ferrite (PEG-MnFe2O4) nanoparticles (NPs) modified onto a glassy carbon electrode (GCE) is reported in the present study. XRD and Raman studies confirmed the cubic spinel structure of MnFe(2)O(4.)The immobilization of glucose oxidase (GOx) on PEG-MnFe2O4 (GOx@PEG-MnFe2O4) was validated using FTIR and TGA. Sensing electrodes exhibited well-defined redox peaks in 0.1 M phosphate buffered saline (PBS) solution at pH 7.4 against the reference electrode Ag/AgCl. GOx@PEG-MnFe2O4/GCE displayed a sensitivity of 1.985 mu A mM(-1)cm(-2) in the linear range of 1 to 20 mM with a limit of detection (LOD) of 0.132 mM whereas non-enzymatic sensor exhibited a sensitivity of 1.044 mu A mM(-1)cm(-2) in the linear range of 1 to 10 mM with a LOD of 0.099 mM. The lower Michaelis constant (K-m(app)<i) value indicates greater affinity towards glucose for the enzymatic sensor. GOx@PEG-MnFe2O4 revealed selectivity specifically for glucose over various interferants such as fructose, lactic acid, sucrose, uric acid and ascorbic acid. In addition, this enzymatic sensor demonstrated better reproducibility and lifetime.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] A novel sensitive non-enzymatic glucose sensor
    Xin Huang Kang
    [J]. Chinese Chemical Letters, 2007, (02) : 189 - 191
  • [42] Metal nanostructures for non-enzymatic glucose sensing
    Tee, Si Yin
    Teng, Choon Peng
    Ye, Enyi
    [J]. MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 70 : 1018 - 1030
  • [43] Pd nanocube as non-enzymatic glucose sensor
    Ye, Jyun-Sian
    Chen, Chin-Wei
    Lee, Chien-Liang
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 : 569 - 574
  • [44] Non-enzymatic continuous glucose monitoring system
    Moore S.
    You B.H.
    Kim N.
    Park T.
    Song I.-H.
    [J]. Song, In-Hyouk (in-hyouk.song@txstate.edu), 2018, John Wiley and Sons Inc (13): : 1079 - 1084
  • [45] Nanomaterials for electrochemical non-enzymatic glucose biosensors
    Si, Peng
    Huang, Youju
    Wang, Taihong
    Ma, Jianmin
    [J]. RSC Advances, 2013, 3 (11) : 3487 - 3502
  • [46] A novel sensitive non-enzymatic glucose sensor
    Kang, Xin Huang
    Mai, Zhi Bin
    Zou, Xiao Yong
    Cai, Pei Xiang
    Mo, Jin Yuan
    [J]. CHINESE CHEMICAL LETTERS, 2007, 18 (02) : 189 - 191
  • [47] Non-enzymatic continuous glucose monitoring system
    Moore, Sean
    You, Byoung Hee
    Kim, Namwon
    Park, Taehyun
    Song, In-Hyouk
    [J]. MICRO & NANO LETTERS, 2018, 13 (08): : 1079 - 1084
  • [48] Non-enzymatic and non-invasive glucose detection using Au nanoparticle decorated CuO nanorods
    Chakraborty, Pinak
    Dhar, Saurab
    Debnath, Kamalesh
    Majumder, Tanmoy
    Mondal, Suvra Prakash
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2019, 283 : 776 - 785
  • [49] Dendritic platinum-decorated gold nanoparticles for non-enzymatic glucose biosensing
    Chen, Kuan-Jung
    Su, Wei-Nien
    Pan, Chun-Jern
    Cheng, Shou-Yi
    Rick, John
    Wang, Shih-Han
    Liu, Chung-Chiun
    Chang, Chun-Chao
    Yang, Yaw-Wen
    Wang, Chia-Hsin
    Hwang, Bing-Joe
    [J]. JOURNAL OF MATERIALS CHEMISTRY B, 2013, 1 (43) : 5925 - 5932
  • [50] Novel synthesis and characterization of pristine Cu nanoparticles for the non-enzymatic glucose biosensor
    T. Dayakar
    K. Venkateswara Rao
    K. Bikshalu
    V. Rajendar
    Si-Hyun Park
    [J]. Journal of Materials Science: Materials in Medicine, 2017, 28