Calibration of a DSSSD detector with radioactive sources

被引:0
|
作者
Guadilla, V. [1 ]
Tain, J. L. [1 ]
Agramunt, J. [1 ]
Algora, A. [1 ]
Domingo-Pardo, C. [1 ]
Rubio, B. [1 ]
机构
[1] Univ Valencia, CSIC, Inst Fis Corpuscular, E-46071 Valencia, Spain
关键词
DSSSD; fragmentation experiments; energy calibration;
D O I
10.1063/1.4810833
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The energy calibration of a DSSSD is carried out with the spectra produced by a Bi-207 conversion electron source, a Cs-137 gamma source and a Pu-239/Am-241/Cm-244 triple alpha source, as well as employing a precision pulse generator in the whole dynamic range. Multiplicity and coincidence of signals in different strips for the same event are also studied.
引用
收藏
页码:173 / 174
页数:2
相关论文
共 50 条
  • [21] COMPARATIVE INVESTIGATION OF RADIOACTIVE SOURCES FOR THE ELECTRON-CAPTURE DETECTOR
    AYALA, JA
    WENTWORTH, WE
    CHEN, ECM
    JOURNAL OF CHROMATOGRAPHY, 1980, 195 (01): : 1 - 15
  • [22] Detection efficiency calibration of radioactive standard soil matter with HPGe detector
    Beijing Radiation Environment Management Center, Beijing 100089, China
    不详
    Yuanzineng Kexue Jishu, 2006, 6 (749-751):
  • [23] Detector sensitivity and calibration for yield measurements in fusion neutron sources
    Andola, Sanjay
    Rawool, A. M.
    Kaushik, T. C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 944
  • [24] An empirical formula for HPGe γ detector efficiency calibration for bulky sources
    Nie Peng
    Ni Bang-fa
    Tian Wei-zhi
    RADIATION PHYSICS AND CHEMISTRY, 2012, 81 (01) : 9 - 11
  • [25] TECHNIQUE OF GAMMA-RAY DETECTOR CALIBRATION FOR EXTENDED SOURCES
    CLINE, JE
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1978, 28 : 15 - 15
  • [26] Detector Efficiency Calibration for Extended Gamma-Ray Sources
    dos Santos, Roberto M.
    Genezini, Frederico A.
    Zahn, Guilherme S.
    XXXIII BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 2011, 1351
  • [27] Performance tests of a silicon strip detector with radioactive sources and proton beam
    Kim, Y. I.
    Kang, Heedong
    Kim, H. J.
    Park, H.
    Ryu, S.
    Son, D. H.
    Kim, Kyeryung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 52 (03) : 828 - 831
  • [28] HPGe virtual point detector for radioactive volume-ring sources
    Nasrabadi, M. N.
    Kashi, S. H.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [29] THE CALIBRATION OF PROPORTIONAL COUNTERS WITH X-RAYS PRODUCED BY RADIOACTIVE SOURCES
    ROTHWELL, P
    WEST, D
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION A, 1950, 63 (365): : 541 - 543
  • [30] Time of flight coincidence timing calibration, techniques using radioactive sources
    Perkins, A. E.
    Werner, M.
    Kuhn, A.
    Surti, S.
    Muehllehner, G.
    Karp, J. S.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2488 - 2491