The 'infinite velocity method': a means of concentration calibration in secondary ion mass spectrometry?

被引:27
|
作者
Wittmaack, K [1 ]
机构
[1] GSF Forschungszentrum Umwelt & Gesundheit, Inst Strahlenschutz, D-85758 Neuherberg, Germany
关键词
quantification; secondary ion mass spectrometry;
D O I
10.1016/S0039-6028(99)00341-6
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The so-called infinite velocity (iv) method, recently suggested by P. van der Heide as a means of quantifying, without standards, the signals measured by secondary ion mass spectrometry (SIMS), has been analysed critically. The iv method is essentially based upon two assumptions. (1) Secondary ion energy spectra can be described as a product of the isotopic concentration of the analysed species, the flux of sputtered neutrals, the instrument transmission, the detector efficiency, and the ionization probability, an ansatz that had already been used repeatedly in earlier work. (2) The ionization probability increases exponentially with decreasing inverse ion velocity, and in the limit of infinite velocity, all sputtered atoms are fully ionized. Hence, the matrix effect in SIMS is removed. Secondary ion yields at infinite velocity can be derived by extrapolation of measured energy spectra after eliminating the energy dependence of the sputtered atom flux and the instrument transmission, both considered to be the same for all elements and isotopes. It is shown that, if the energy-dependent neutral flux and the instrument transmission were in fact universal correction functions, concentration calibration could be achieved by extrapolation of ion yield ratios, without even knowing the analytical form of these functions. Literature results as well as (re)analysed data of van der Heide provide clear evidence that the matrix effect is not removed at infinite velocity. Many of the previously ignored problems originate from the fact that the formalism used for data processing has never been outlined in a quantitatively correct manner. As a result, the importance of normalization factors associated with the use of the unknown input functions remained unnoticed (e.g. the surface binding energy and the shape of the energy and angular distributions). Element-specific differences in these parameters give rise to corresponding errors in concentration calibration. The frequently derived non-exponential inverse-velocity dependence of the 'corrected' ion yields can be reproduced if one considers rather small deviations from the arbitrary assumptions made in the data processing. It is concluded that, even if all errors in the basic formalism are removed, the iv method does not provide reliable data, neither on elemental concentrations nor on ionization or neutralization phenomena, the reason being that (1) none of the parameters and functions required for extracting ion fractions from measured energy spectra is known with the required accuracy, and (2) the matrix effect cannot be removed by extrapolation procedures. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:84 / 101
页数:18
相关论文
共 50 条
  • [31] DETERMINATION OF DIMETHYLTHALLIUM IONS BY MEANS OF SECONDARY ION MASS-SPECTROMETRY AFTER EXTRACTION
    GUNTHER, K
    UMLAND, F
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 333 (01): : 6 - 8
  • [32] ANALYSIS OF CONDUCTING AND INSULATING SURFACES BY MEANS OF SECONDARY ION MASS-SPECTROMETRY (SIMS)
    DEPAZ, M
    MACCIO, C
    ZEITSCHRIFT FUR NATURFORSCHUNG SECTION A-A JOURNAL OF PHYSICAL SCIENCES, 1975, 30 (6-7): : 831 - 834
  • [33] Calibration method for the quantitative analysis of gas mixtures by means of multiphoton ionization mass spectrometry
    Boesl, U.
    Weickhardt, C.
    Schmidt, S.
    Nagel, H.
    Schlag, E.W.
    Review of Scientific Instruments, 1993, 64 (12): : 3482 - 3486
  • [34] Calibration point for liquid secondary ion mass spectrometry tandem mass spectra measured with an EBqQ hybrid mass spectrometer
    Lemire, SW
    Busch, KL
    JOURNAL OF MASS SPECTROMETRY, 1996, 31 (03): : 280 - 288
  • [35] CROSS CALIBRATION OF SECONDARY ION MASS SPECTROMETERS
    RUDENAUER, F
    STEIGER, W
    RIEDEL, M
    BESKE, HE
    HOLZBRECHER, H
    DUSTERHOFT, H
    GERICKE, M
    RICHTER, CE
    RIETH, M
    TRAPP, M
    GIBER, J
    SOLYOM, A
    MAI, H
    STINGEDER, G
    ANALYTICAL CHEMISTRY, 1985, 57 (08) : 1636 - 1643
  • [36] Determination of the concentration of impurities in GaN from photoluminescence and secondary-ion mass spectrometry
    Reshchikov, M. A.
    Vorobiov, M.
    Andrieiev, O.
    Ding, K.
    Izyumskaya, N.
    Avrutin, V
    Usikov, A.
    Helava, H.
    Makarov, Yu
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [37] Determination of the concentration of impurities in GaN from photoluminescence and secondary-ion mass spectrometry
    M. A. Reshchikov
    M. Vorobiov
    O. Andrieiev
    K. Ding
    N. Izyumskaya
    V. Avrutin
    A. Usikov
    H. Helava
    Yu. Makarov
    Scientific Reports, 10
  • [38] In-depth concentration profiles of metals in glass waveguides by secondary ion mass spectrometry
    Gonella, F
    Caccavale, F
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 1996, 14 (04): : 695 - 702
  • [39] MEASUREMENT OF CONCENTRATION PROFILES OF BORON IMPLANTATIONS IN SILICON BY SECONDARY ION MASS-SPECTROMETRY
    HOFKER, W
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1974, : 91 - 91
  • [40] ION NEUTRALIZATION IN SECONDARY ION MASS-SPECTROMETRY
    GARRETT, RF
    MACDONALD, RJ
    OCONNOR, DJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 218 (1-3): : 333 - 335