Children With Single-Sided Deafness Use Their Cochlear Implant

被引:41
|
作者
Polonenko, Melissa Jane [1 ,2 ,3 ,4 ]
Papsin, Blake Croll [1 ,3 ,5 ,6 ]
Gordon, Karen Ann [1 ,2 ,3 ,6 ]
机构
[1] Hosp Sick Children, Archies Cochlear Implant Lab, Room 6D08,555 Univ Ave, Toronto, ON M5G 1X8, Canada
[2] Hosp Sick Children, Neurosci & Mental Hlth, Toronto, ON, Canada
[3] Univ Toronto, Inst Med Sci, Toronto, ON, Canada
[4] Univ Toronto, Collaborat Program Neurosci, Toronto, ON, Canada
[5] Hosp Sick Children, Dept Otolaryngol Head & Neck Surg, Toronto, ON, Canada
[6] Univ Toronto, Dept Otolaryngol Head & Neck Surg, Toronto, ON, Canada
来源
EAR AND HEARING | 2017年 / 38卷 / 06期
基金
加拿大健康研究院;
关键词
Bimodal experience; Cochlear implant; Cochlear implant experience; Coil-off; Device use; Electroacoustic hearing; Hearing experience; Intensity; SCAN; Noise; Nucleus 6 speech processor; Quiet; Sensorineural hearing loss; Single-sided deafness; Speech; Speech in noise; Unilateral hearing loss; HEARING-AID USE; BRAIN-STEM ACTIVITY; ASYMMETRIC HEARING; UNILATERAL DEAFNESS; AURAL PREFERENCE; REORGANIZATION; LOCALIZATION; STIMULATION; ADOLESCENTS; PERFORMANCE;
D O I
10.1097/AUD.0000000000000452
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: To assess acceptance of a cochlear implant (CI) by children with single-sided deafness (SSD) as measured by duration of CI use across daily listening environments. Design: Datalogs for 7 children aged 1.1 to 14.5 years (mean +/- SD: 5.9 +/- 5.9 years old), who had SSD and were implanted in their deaf ear, were anonymized and extracted from their CI processors. Data for all available follow-up clinical appointments were included, ranging from two to six visits. Measures calculated from each datalog included frequency and duration of time the coil disconnected from the internal device, average daily CI use, and both duration (hr/day) and percentage of CI use (% daily use) in different intensity ranges and environment types. Linear mixed effects regression analyses were used to evaluate the relationships between CI experience, daily CI use, frequency of coil-offs, and duration of coil-off time. Nonlinear regression analyses were used to evaluate CI use with age in different acoustic environments. Results: Children with SSD used their CI on average 7.4 hr/day. Older children used their CI for longer periods of the day than younger children. Longitudinal data indicated consistent CI use from the date of CI activation. Frequency of coil-offs reduced with CI experience, but did not significantly contribute to hours of coil-off time. Children used their CI longest in environments that were moderately loud (50 to 70 dB A) and classified as containing speech-in-noise. Preschoolers tended to spend less time in quiet but more time in music than infants/toddlers and adolescents. Conclusions: Children with SSD consistently use their CI upon activation in a variety of environments commonly experienced by children. CI use in children with SSD resembles reported bilateral hearing aid use in children but is longer than reported hearing aid use in children with less severe unilateral hearing loss, suggesting that (1) the normal-hearing ear did not detract from consistent CI use; and (2) a greater asymmetry between ears presents a significant impairment that may facilitate device use to access bilateral sound.
引用
收藏
页码:681 / 689
页数:9
相关论文
共 50 条
  • [31] Correction to: The impact of cochlear implant microphone settings on the binaural hearing of experienced cochlear implant users with single-sided deafness
    Anja Kurz
    Maren Zanzinger
    Rudolf Hagen
    Kristen Rak
    European Archives of Oto-Rhino-Laryngology, 2021, 278 : 2079 - 2079
  • [32] Long-Term Improvement in Localization for Cochlear Implant Users with Single-Sided Deafness
    Thompson, Nicholas J.
    Dillon, Margaret T.
    Buss, Emily
    Rooth, Meredith A.
    Richter, Margaret E.
    Pillsbury, Harold C.
    Brown, Kevin D.
    LARYNGOSCOPE, 2022, 132 (12): : 2453 - 2458
  • [33] Pediatric Single-Sided Deafness: A Review of Prevalence, Radiologic Findings, and Cochlear Implant Candidacy
    Dewyer, Nicholas A.
    Smith, Sullivan
    Herrmann, Barbara
    Reinshagen, Katherine L.
    Lee, Daniel J.
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2022, 131 (03): : 233 - 238
  • [34] Cost Effectiveness of Cochlear Implantation in Single-Sided Deafness
    Dreyfuss, Michael
    Giat, Yahel
    Veraguth, Dorothe
    Roosli, Christof
    Huber, Alexander M.
    Laske, Roman D.
    OTOLOGY & NEUROTOLOGY, 2021, 42 (08) : 1129 - 1135
  • [35] Cochlear implantation in a child with posttraumatic single-sided deafness
    Plontke, Stefan K.
    Heider, Cornelia
    Koesling, Sabrina
    Hess, Soeren
    Bieseke, Lars
    Goetze, Gerrit
    Rahne, Torsten
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2013, 270 (05) : 1757 - 1761
  • [36] Cochlear implantation for single-sided deafness and tinnitus suppression
    Holder, Jourdan T.
    O'Connell, Brendan
    Hedley-Williams, Andrea
    Wanna, George
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2017, 38 (02) : 226 - 229
  • [37] Audiological results with cochlear implants for single-sided deafness
    Jacob, R.
    Stelzig, Y.
    Nopp, P.
    Schleich, P.
    HNO, 2011, 59 (05) : 453 - 460
  • [38] Cochlear Implantation for Single-Sided Deafness: A Multicenter Study
    Sladen, Douglas P.
    Frisch, Christopher D.
    Carlson, Matthew L.
    Driscoll, Colin L. W.
    Torres, Jennifer H.
    Zeitler, Daniel M.
    LARYNGOSCOPE, 2017, 127 (01): : 223 - 228
  • [39] Cochlear implantation in a child with posttraumatic single-sided deafness
    Stefan K. Plontke
    Cornelia Heider
    Sabrina Koesling
    Sören Hess
    Lars Bieseke
    Gerrit Goetze
    Torsten Rahne
    European Archives of Oto-Rhino-Laryngology, 2013, 270 : 1757 - 1761
  • [40] Single-sided Deafness Cochlear Implantation: Candidacy, Evaluation, and Outcomes in Children and Adults
    Friedmann, David R.
    Ahmed, Omar H.
    McMenomey, Sean O.
    Shapiro, William H.
    Waltzman, Susan B.
    Roland, J. Thomas, Jr.
    OTOLOGY & NEUROTOLOGY, 2016, 37 (02) : E154 - E160