EC-VAD: Combined Use of Extracorporeal Membrane Oxygenation and Percutaneous Microaxial Pump Left Ventricular Assist Device

被引:53
|
作者
Akanni, Olutosin J. [1 ]
Takeda, Koji [1 ]
Truby, Lauren K. [2 ]
Kurlansky, Paul A. [1 ]
Chiuzan, Codruta [3 ]
Han, Jiho [1 ]
Topkara, Veli K. [2 ]
Yuzefpolskaya, Melana [2 ]
Colombo, Paolo C. [2 ]
Karmpaliotis, Dimitrios [2 ]
Moses, Jeffery W. [2 ]
Naka, Yoshifumi [1 ]
Garan, A. Reshad [2 ]
Kirtane, Ajay J. [2 ]
Takayama, Hiroo [1 ]
机构
[1] Columbia Univ, Med Ctr, Dept Surg, Div Cardiothorac Surg, New York, NY USA
[2] Columbia Univ, Dept Med, Div Cardiol, Med Ctr, New York, NY USA
[3] Columbia Univ, Mailman Sch Publ Hlth, Dept Biostat, New York, NY USA
关键词
mechanical circulatory support; heart failure; MECHANICAL CIRCULATORY SUPPORT; REFRACTORY CARDIOGENIC-SHOCK; DECOMPRESSION; IMPELLA; DISTENSION; BRIDGE; CARE;
D O I
10.1097/MAT.0000000000000804
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Combination of venoarterial extracorporeal membrane oxygenation (VA-ECMO) and a percutaneous microaxial left ventricular assist device (pLVAD), or "EC-VAD," has been reported in cases of left ventricular decompression with mixed results. We conducted a retrospective review of patients who received EC-VAD (n = 29) or isolated VA-ECMO therapy (ECMO-only; n = 196) for refractory cardiogenic shock between February 2011 and October 2014. Fourteen patients received VA-ECMO and then Impella pLVAD (E -> EC-VAD), and 15 received the Impella pump then VA-ECMO (I -> EC-VAD). E -> EC-VAD patients demonstrated decreased pulmonary artery systolic (36.00 +/- 16.84 mm Hg versus 30.63 +/- 12.13 mm Hg; p = 0.049) and diastolic (24.25 +/- 13.45 mm Hg versus 17.25 +/- 7.96 mm Hg, p = 0.049) pressures by 24 hours post-EC-VAD implant. In the same period, I -> EC-VAD patients demonstrated improved SvO2 (43.14 +/- 16.75% versus 75.18 +/- 13.88%, p = 0.043) and PaO2/FiO2 ratio (148.55 +/- 67.69 mm Hg versus 374.51 +/- 170.97 mm Hg, p = 0.043). Thirty-day survival rates were 42.9% in E -> EC-VAD, 46.7% in I -> EC-VAD, and 49.0% in ECMO-only (p = 0.913). Hemolysis occurred more in EC-VAD patients (44.83% versus 17.35% in ECMO-only, p = 0.002); however, there was no increased frequency of other adverse events including bleeding and lower limb ischemia. Despite increased hemolysis, combined use of VA-ECMO and pLVAD may improve or circumvent left ventricular distension in refractory cardiogenic shock while promoting adequate blood flow.
引用
收藏
页码:219 / 226
页数:8
相关论文
共 50 条
  • [41] Left Ventricular Decompression During Peripheral Extracorporeal Membrane Oxygenation Support With the Use of the Novel iVAC Pulsatile Paracorporeal Assist Device
    Anastasiadis, Kyriakos
    Chalvatzoulis, Omiros
    Antonitsis, Polychronis
    Tossios, Paschalis
    Papakonstantinou, Christos
    ANNALS OF THORACIC SURGERY, 2011, 92 (06): : 2257 - 2259
  • [42] Impella - Current issues and future expectations for the percutaneous, microaxial flow left ventricular assist device
    Saito, Shunsuke
    Okubo, Shohei
    Matsuoka, Taiki
    Hirota, Shotaro
    Yokoyama, Shohei
    Kanazawa, Yuta
    Takei, Yusuke
    Tezuka, Masahiro
    Tsuchiya, Go
    Konishi, Taisuke
    Shibasaki, Ikuko
    Ogata, Koji
    Fukuda, Hirotsugu
    JOURNAL OF CARDIOLOGY, 2024, 83 (04) : 228 - 235
  • [43] Outcomes After Extracorporeal Right Ventricular Assist Device Combined With Durable Left Ventricular Assist Device Support
    Khorsandi, Maziar
    Schroder, Jacob
    Daneshmand, Mani
    Bishawi, Muath
    Bouamra, Omar
    Winterton, Patrick
    Choi, Ashley Y.
    Patel, Chetan
    Rogers, Joseph
    Del Rio, J. Mauricio
    Milano, Carmelo
    ANNALS OF THORACIC SURGERY, 2019, 107 (06): : 1768 - 1774
  • [44] Intravascular Microaxial Left Ventricular Assist Device Manufacturer Payments to Cardiologists and Use of Devices
    Dhruva, Sanket S.
    Ross, Joseph S.
    Steinman, Michael A.
    Gan, Siqi
    Muluk, Sruthi
    Anderson, Timothy S.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2024, 331 (17): : 1499 - 1501
  • [45] Impact of MELD Score on Outcome in Patients with Percutaneous Extracorporeal Membrane Oxygenation Followed by Ventricular Assist Device Implantation
    Seguchi, Osamu
    Fujita, Tomoyuki
    Sato, Takuma
    Sunami, Haruki
    Yanase, Masanobu
    Hata, Hiroki
    Nakatani, Takeshi
    JOURNAL OF CARDIAC FAILURE, 2014, 20 (10) : S203 - S203
  • [46] Percutaneous deactivation of a left ventricular assist device due to pump thrombosis
    Bohdan, Michal
    Kolaczkowska, Magdalena
    Radtke-Lysek, Alicja
    Targonski, Radoslaw
    Siondalski, Piotr
    Rogowski, Jan
    Gruchala, Marcin
    KARDIOLOGIA POLSKA, 2023, 81 (7-8) : 796 - 797
  • [47] Left Ventricular Decompression Using a Percutaneous Transvalvular Microaxial Ventricular Assist Device in Patients Receiving VA ECMO
    Allen, Christopher T.
    Litton, Edward
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (05) : 1479 - 1480
  • [48] Mechanical bridge with extracorporeal membrane oxygenation and ventricular assist device to heart transplantation
    Wang, SS
    Ko, WJ
    Chen, YS
    Hsu, RB
    Chou, NK
    Chu, SH
    ARTIFICIAL ORGANS, 2001, 25 (08) : 599 - 602
  • [49] Percutaneous Ventricular Assist Device and Extracorporeal Membrane Oxygenation Support in a Patient with Postinfarction Ventricular Septal Defect and Free Wall Rupture
    Gregoric, Igor D.
    Mesar, Tomaz
    Kar, Biswajit
    Nathan, Sriram
    Radovancevic, Rajko
    Patel, Manish
    Loyalka, Pranav
    HEART SURGERY FORUM, 2013, 16 (03): : E150 - E151
  • [50] Impact of preoperative extracorporeal membrane oxygenation on vasoactive inotrope score after implantation of left ventricular assist device
    Maeda, Takuma
    Toda, Koichi
    Kamei, Masataka
    Miyata, Shigeki
    Ohnishi, Yoshihiko
    SPRINGERPLUS, 2015, 4 : 1 - 6