EC-VAD: Combined Use of Extracorporeal Membrane Oxygenation and Percutaneous Microaxial Pump Left Ventricular Assist Device

被引:53
|
作者
Akanni, Olutosin J. [1 ]
Takeda, Koji [1 ]
Truby, Lauren K. [2 ]
Kurlansky, Paul A. [1 ]
Chiuzan, Codruta [3 ]
Han, Jiho [1 ]
Topkara, Veli K. [2 ]
Yuzefpolskaya, Melana [2 ]
Colombo, Paolo C. [2 ]
Karmpaliotis, Dimitrios [2 ]
Moses, Jeffery W. [2 ]
Naka, Yoshifumi [1 ]
Garan, A. Reshad [2 ]
Kirtane, Ajay J. [2 ]
Takayama, Hiroo [1 ]
机构
[1] Columbia Univ, Med Ctr, Dept Surg, Div Cardiothorac Surg, New York, NY USA
[2] Columbia Univ, Dept Med, Div Cardiol, Med Ctr, New York, NY USA
[3] Columbia Univ, Mailman Sch Publ Hlth, Dept Biostat, New York, NY USA
关键词
mechanical circulatory support; heart failure; MECHANICAL CIRCULATORY SUPPORT; REFRACTORY CARDIOGENIC-SHOCK; DECOMPRESSION; IMPELLA; DISTENSION; BRIDGE; CARE;
D O I
10.1097/MAT.0000000000000804
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Combination of venoarterial extracorporeal membrane oxygenation (VA-ECMO) and a percutaneous microaxial left ventricular assist device (pLVAD), or "EC-VAD," has been reported in cases of left ventricular decompression with mixed results. We conducted a retrospective review of patients who received EC-VAD (n = 29) or isolated VA-ECMO therapy (ECMO-only; n = 196) for refractory cardiogenic shock between February 2011 and October 2014. Fourteen patients received VA-ECMO and then Impella pLVAD (E -> EC-VAD), and 15 received the Impella pump then VA-ECMO (I -> EC-VAD). E -> EC-VAD patients demonstrated decreased pulmonary artery systolic (36.00 +/- 16.84 mm Hg versus 30.63 +/- 12.13 mm Hg; p = 0.049) and diastolic (24.25 +/- 13.45 mm Hg versus 17.25 +/- 7.96 mm Hg, p = 0.049) pressures by 24 hours post-EC-VAD implant. In the same period, I -> EC-VAD patients demonstrated improved SvO2 (43.14 +/- 16.75% versus 75.18 +/- 13.88%, p = 0.043) and PaO2/FiO2 ratio (148.55 +/- 67.69 mm Hg versus 374.51 +/- 170.97 mm Hg, p = 0.043). Thirty-day survival rates were 42.9% in E -> EC-VAD, 46.7% in I -> EC-VAD, and 49.0% in ECMO-only (p = 0.913). Hemolysis occurred more in EC-VAD patients (44.83% versus 17.35% in ECMO-only, p = 0.002); however, there was no increased frequency of other adverse events including bleeding and lower limb ischemia. Despite increased hemolysis, combined use of VA-ECMO and pLVAD may improve or circumvent left ventricular distension in refractory cardiogenic shock while promoting adequate blood flow.
引用
收藏
页码:219 / 226
页数:8
相关论文
共 50 条
  • [1] ECPELLA: Combined Use of Extracorporeal Membrane Oxygenation and Percutaneous Microaxial Pump Left Ventricular Assist Device
    Akanni, O.
    Takeda, K.
    Truby, L.
    Kurlansky, P.
    Han, J.
    Sreekanth, S.
    Garan, A. R.
    Topkara, V. K.
    Yuzefpolskaya, M.
    Colombo, P.
    Kirtane, A.
    Naka, Y.
    Takayama, H.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S323 - S323
  • [2] Concomitant use of extracorporeal membrane oxygenation and percutaneous microaxial assist device support for cardiogenic shock
    Modi, Shan P.
    Hong, Yeahwa
    Sicke, McKenzie M.
    Hess, Nicholas R.
    Klass, Wyatt J.
    Ziegler, Luke A.
    Rivosecchi, Ryan M.
    Hickey, Gavin W.
    Kaczorowski, David J.
    Ramanan, Raj
    JTCVS OPEN, 2024, 17 : 152 - 161
  • [3] In Hospital Outcomes With Extracorporeal Membrane Oxygenation Alone vs Combined With Percutaneous Left Ventricular Assist Device
    Lakhani, Fatima
    Ebner, Bertrand
    Kaur, Sukhpreet
    Colombo, Rosario
    Munagala, Mrudula
    CIRCULATION, 2023, 148
  • [4] In-hospital outcomes with extracorporeal membrane oxygenation alone versus combined with percutaneous left ventricular assist device
    Lakhani, Fatima
    Ebner, Bertrand
    Yan, Crystal Lihong
    Kaur, Sukhpreet
    Colombo, Rosario
    Munagala, Mrudula
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2024, 68 : 50 - 54
  • [5] Combined Use of Impella Left Ventricular Assist Device and Extracorporeal Membrane Oxygenation as a Bridge to Recovery in Fulminant Myocarditis
    Chaparro, Sandra V.
    Badheka, Apurva
    Marzouka, George R.
    Tanawuttiwat, Tanyanan
    Ahmed, Fayaz
    Sacher, Vikas
    Pham, Si M.
    ASAIO JOURNAL, 2012, 58 (03) : 285 - 287
  • [6] Role of percutaneous veno-arterial extracorporeal membrane oxygenation as bridge to left ventricular assist device
    Koichi Toda
    Tomoyuki Fujita
    Osamu Seguchi
    Masanobu Yanase
    Takeshi Nakatani
    Journal of Artificial Organs, 2018, 21 : 39 - 45
  • [7] Role of percutaneous veno-arterial extracorporeal membrane oxygenation as bridge to left ventricular assist device
    Toda, Koichi
    Fujita, Tomoyuki
    Seguchi, Osamu
    Yanase, Masanobu
    Nakatani, Takeshi
    JOURNAL OF ARTIFICIAL ORGANS, 2018, 21 (01) : 39 - 45
  • [8] Extracorporeal membrane oxygenation for right ventricular support in left ventricular assist device recipients
    Riebandt, Julia
    Moayedifar, Roxana
    Laufer, Guenther
    Zimpfer, Daniel
    ANNALS OF CARDIOTHORACIC SURGERY, 2019, 8 (01) : 170 - 172
  • [9] Right-to-Left Interatrial Shunt Inversion Using a Percutaneous Left Ventricular Assist Device and Extracorporeal Membrane Oxygenation
    Inoue, Motoi
    Fukushima, Yutaka
    Imashuku, Yasuhiko
    Mizuno, Takayoshi
    Kitagawa, Hirotoshi
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2024, 38 (11) : 2850 - 2851
  • [10] Combined extracorporeal membrane oxygenation and microaxial pump-when left ventricular preload is too low to unload in cardiogenic shock
    Luesebrink, Enzo
    Massberg, Steffen
    Orban, Martin
    HEALTH SCIENCE REPORTS, 2021, 4 (03)