共 50 条
Immediate Loading of Two Unsplinted Implants in Edentulous Patients with Mandibular Overdentures: A 10-year Retrospective Review of Patients from a Previously Conducted 1-year Cohort Study
被引:10
|作者:
Rignon-Bret, Christophe
[1
,2
]
Wulfman, Claudine
[1
,2
]
Hadida, Alain
[1
,2
]
Renouard, Franck
Gourraud, Pierre-Antoine
[3
,4
]
Naveau, Adrien
[1
,2
]
机构:
[1] Paris Descartes Univ, Sorbonne Paris Cite, Dent Fac, Paris, France
[2] Henri Mondor Hosp Univ Grp, AP HP, Dent Dept, Creteil, France
[3] Acad Hosp, INSERM, UMR 1064, Nantes, France
[4] Univ Nantes, Nantes, France
关键词:
ball abutment;
immediate loading;
implant overdenture;
implant success;
unsplinted implants;
MARGINAL BONE LOSS;
RESONANCE FREQUENCY-ANALYSIS;
RANDOMIZED CLINICAL-TRIAL;
QUALITY-OF-LIFE;
RETAINED OVERDENTURES;
SUPPORTED OVERDENTURES;
FOLLOW-UP;
SATISFACTION;
DENTURES;
PROSTHESES;
D O I:
10.11607/jomi.6931
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
Purpose: This 10-year retrospective study aimed to report implant bone changes in completely edentulous patients after a mandibular immediate loading protocol using two ball attachments. Materials and Methods: This study was initially designed as a prospective 1-year cohort study, then extended with a 10-year retrospective evaluation of implant bone change. In the first part of the study, 43 edentulous patients wearing satisfactory maxillary and mandibular dentures for at least 3 months were included. Two interforaminal implants (Branemark system, Nobel Biocare) were placed symmetrically in the anterior mandible using a surgical template and a torque greater than 40 Ncm. Immediately following surgery, 2.25-mm-diameter ball abutments were screwed to the implants, and their matrices (Dalbo Plus, Cendres et Metaux) were incorporated in the denture base. In an initial 1-year study, clinical recalls were scheduled 3, 6, and 12 months after implant placement with a team of two investigators. The follow-up consisted of a clinical examination and a standardized radiographic assessment of the vertical bone change. Implant stability was then monitored. The patient satisfaction was evaluated with a questionnaire before and 3 months after loading. The second part of the study occurred 10 years after the inclusion, as patients were recalled for an implant bone change monitoring. Results: The included patients were 28 to 80 years of age (mean: 61 +/- 11.4 years). Three out of 86 implants failed during the healing phase (survival rate of 96.5% [90.1%, 99.2%]). Implant stability was maintained all along the 1-year follow-up (Delta = 73.33, 95% CI [72.39 to 74.26], P =.032). The mean radiographic bone loss was 0.27 +/- 0.35 mm at 3 months after surgery, 0.47 +/- 0.42 mm after 1 year, and 0.95 +/- 0.98 mm after 10 years. General visual analog scale satisfaction was increased by 25 units with the treatment. No patients were lost to follow-up at 1 year, but five were lost at 10 years. Conclusion: This protocol of immediate loading of two unsplinted mandibular implants in overdenture patients using ball attachments is a clinically viable treatment with a high implant success rate and improved satisfaction.
引用
收藏
页码:169 / 178
页数:10
相关论文