Immediate Loading of Two Freestanding Implants Retaining a Mandibular Overdenture: 1-Year Pilot Prospective Study

被引:0
|
作者
Liao, Kuo-Yang [1 ]
Kan, Joseph Y. [2 ]
Rungcharassaeng, Kitichai [3 ]
Lozada, Jaime L. [1 ]
Herford, Alan S. [4 ]
Goodacre, Charles J. [2 ]
机构
[1] Loma Linda Univ, Sch Dent, Loma Linda, CA 92350 USA
[2] Loma Linda Univ, Sch Dent, Dept Restorat Dent, Loma Linda, CA 92350 USA
[3] Loma Linda Univ, Dept Orthodont, Loma Linda, CA 92350 USA
[4] Loma Linda Univ, Sch Dent, Dept Oral & Maxillofacial Surg, Loma Linda, CA 92350 USA
关键词
ball-attachment; immediate loading; implant-supported prosthesis; mandibular overdenture; prospective; two freestanding implants; RANDOMIZED CLINICAL-TRIAL; MARGINAL BONE LOSS; EDENTULOUS PATIENTS; BRANEMARK IMPLANTS; DENTAL IMPLANTS; COATED IMPLANTS; ITI IMPLANTS; MULTICENTER; SYSTEM; RECONSTRUCTION;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this 1-year pilot prospective study was to evaluate the implant success rate, peri-implant tissue response, and complications associated with the immediate loading of two freestanding implants retaining mandibular overdentures. Materials and Methods: Ten adults with a mean age of 59.7 years (range, 43 to 78 years) underwent treatment that included a maxillary removable complete denture opposing a mandibular removable overdenture retained by two freestanding, threaded, titanium oxide-surface implants with a 3-mm machined collar (n = 20 implants). The success of each implant was evaluated clinically and radiographically. Marginal bone levels and changes were evaluated using sequential standardized periapical radiographs. Surgical and prosthetic complications were recorded. Results: Two patients, one with one failed implant, dropped out prior to completion of the study. The failed implants were included in the evaluation of cumulative implant success. The cumulative implant success rate at 1 year was 94% (16/17). The mean marginal bone loss was 1.12 +/- 1.10 mm at 12 months. However, if the expected bone loss of 0.39 mm above the smooth-rough implant surface junction was considered, the mean marginal bone loss was only 0.73 mm. Mean Periotest values of -4.25 +/- 0.93 at 1 year implied that osseointegration had been achieved for all successful implants. Modified Plaque Index scores of 0 and 1 were recorded throughout the duration of the study. No irreversible surgical and/or prosthetic complications were observed. Conclusions: In this 1-year pilot prospective study, two immediately loaded unsplinted mandibular symphyseal implants retaining an overdenture resulted in favorable implant success and pen-implant tissue response. INT J ORAL MAXILLOFAC IMPLANTS 2010;25:784-790
引用
收藏
页码:784 / 790
页数:7
相关论文
共 50 条
  • [1] Immediate loading of two unsplinted implants retaining the existing complete mandibular denture in elderly edentulous patients: 1-year results from a multicentre prospective cohort study
    Grandi, Tommaso
    Guazzi, Paolo
    Samarani, Rawad
    Garuti, Giovanna
    Grandi, Giovanni
    [J]. EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2012, 5 (01) : 61 - 68
  • [2] Immediate loading of two implants supporting a ball attachment-retained mandibular overdenture: A prospective clinical study
    Marzola, Riccardo
    Scotti, Roberto
    Fazi, Giovanni
    Schincaglia, Gian Pietro
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2007, 9 (03) : 136 - 143
  • [3] Immediate loading implants with mandibular overdenture: a 48-month prospective follow-up study
    Zancope, Karla
    Simamoto Junior, Paulo Cezar
    Davi, Leticia Resende
    Prado, Celio Jesus
    das Neves, Flavio Domingues
    [J]. BRAZILIAN ORAL RESEARCH, 2014, 28 (04): : 313 - 318
  • [4] Immediate loading of two freestanding implants placed by computer-guided flapless surgery supporting a mandibular overdenture with magnetic attachments
    Sato, Daisuke
    Kanazawa, Manabu
    Kim, You-Kyoung
    Yokoyama, Sawako
    Omura, Yuri
    Ozeki, Masahiko
    Minakuchi, Shunsuke
    Kasugai, Shohei
    Baba, Kazuyoshi
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2016, 60 (01) : 54 - 62
  • [5] Locators versus magnetic attachment effect on peri-implant tissue health of immediate loaded two implants retaining a mandibular overdenture: a 1-year randomised trial
    Elsyad, M. A.
    Mahanna, F. F.
    Elshahat, M. A.
    Elshoukouki, A. H.
    [J]. JOURNAL OF ORAL REHABILITATION, 2016, 43 (04) : 297 - 305
  • [6] Immediate Occlusal Loading of NanoTite™ Tapered Implants: A Prospective 1-Year Clinical and Radiographic Study
    Ostman, Paer-Olov
    Wennerberg, Ann
    Ekestubbe, Annika
    Albrektsson, Tomas
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (06) : 809 - 818
  • [7] Immediate Occlusal Loading of NanoTite™ PREVAIL® Implants: A Prospective 1-Year Clinical and Radiographic Study
    Ostman, Par-Olov
    Wennerberg, Ann
    Albrektsson, Tomas
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2010, 12 (01) : 39 - 47
  • [8] Immediate Loading of Two Implants with a Mandibular Implant-Retained Overdenture: A New Treatment Protocol
    Stoker, Geert T.
    Wismeijer, Daniel
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2011, 13 (04) : 255 - 261
  • [9] Immediate loading of post-extractive single-tooth implants: a 1-year prospective study
    Cristalli, Maria Paola
    Marini, Roberta
    La Monaca, Gerardo
    Sepe, Claudio
    Tonoli, Federica
    Annibali, Susanna
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (09) : 1070 - 1079
  • [10] Immediate Occlusal Loading of Immediately Placed Implants Supporting Fixed Restorations in Completely Edentulous Arches: A 1-Year Prospective Pilot Study
    Pieri, Francesco
    Aldini, Nicolo Nicoli
    Fini, Milena
    Corinaldesi, Giuseppe
    [J]. JOURNAL OF PERIODONTOLOGY, 2009, 80 (03) : 411 - 421