Saturated-core fault current limiters for AC power systems: Towards reliable, economical and better performance application

被引:13
|
作者
Yuan, Jiaxin [1 ,2 ]
Gan, Pengcheng [1 ]
Zhang, Zhaoyang [1 ]
Zhou, Hang [1 ]
Wei, Liangliang [3 ]
Muramatsu, Kazuhiro [4 ]
机构
[1] Wuhan Univ, Sch Elect Engn & Automat, Wuhan 430072, Peoples R China
[2] Wuhan Univ, Shenzhen Inst, Sch Elect Engn & Automat, Shenzhen 518057, Peoples R China
[3] Kyoto Univ, Grad Sch Engn, Dept Elect Engn, Kyoto 6068501, Japan
[4] Saga Univ, Dept Elect & Elect Engn, Saga 8408512, Japan
来源
HIGH VOLTAGE | 2020年 / 5卷 / 04期
关键词
power grids; short-circuit currents; superconducting fault current limiters; AC power systems; power grid capacity; short-circuit current problem; hybrid-type saturated-core fault current limiters; DC-biased-saturated-core fault current limiters; permanent-magnet-saturated-core fault current limiters; superconducting-saturated-core fault current limiters; current-limiting performance; iron core size; DC magnetomotive force; DESIGN;
D O I
10.1049/hve.2019.0049
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the continuous expansion of power grid capacity, the problem of short-circuit current exceeding the standard is becoming increasingly serious. Fault current limiter is a promising solution and is gradually becoming a research hotspot. In this study, fault current limiters are classified into four categories. And saturated-core fault current limiters are emphatically introduced, including its working principle and comparison with the other three categories. Saturated core fault current limiters are divided into four branches according to the ways leading the core saturated. A comprehensive review of the research activities and emerging technologies of saturated-core fault current limiters for AC power systems is presented in this study. The working principle and typical structure of DC-biased-, permanent-magnet-, superconducting- and hybrid-type saturated-core fault current limiters are introduced. The advantages and disadvantages of four types of saturated core fault current limiters are compared in detail from the aspects of current-limiting performance, iron core size and DC magnetomotive force. Real grid application examples of some types of devices are presented, as well as new progress in the techniques, are covered and discussed in detail. One may find the content of this study helpful as a detailed literature review or as practical technical guidance.
引用
收藏
页码:416 / 424
页数:9
相关论文
共 23 条
  • [21] The application of active superconducting DC fault current limiter in hybrid AC/DC power supply systems
    Shi, Jing
    Tang, Yuejin
    Chen, Lei
    Wang, Jin
    Ren, Li
    Li, Jingdong
    Li, Liang
    Peng, Tao
    Cheng, Shijie
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2008, 18 (02) : 672 - 675
  • [22] Parameter Design and Performance Analysis of a Saturated Amorphous Alloy Core Based Fault Current Limiter for Power Grid Applications
    Islam, Md Minarul
    Muttaqi, K. M.
    Sutanto, D.
    2021 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2021,
  • [23] Comparison between saturated-iron core and shielded-iron core superconducting fault current limiters on recloser-fuse coordination of radial distribution systems connected with distributed generation
    Arafa, Aliaa
    Kamel, Salah
    Aly, Mohamed M.
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2021, 22 (03) : 325 - 337