Evaluation of age-associated changes in insulin sensitivity and glucose effectiveness using the insulin modified minimal model method.

被引:0
|
作者
Schuster, DP [1 ]
Osei, K [1 ]
机构
[1] OHIO STATE UNIV,DEPT INTERNAL MED,COLUMBUS,OH 43210
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:A370 / A370
页数:1
相关论文
共 50 条
  • [31] Evaluation of insulin sensitivity and glucose effectiveness during a standardized breakfast test: comparison with the minimal model analysis of an intravenous glucose tolerance test
    Aloulou, K
    Brun, JF
    Mercier, J
    METABOLISM-CLINICAL AND EXPERIMENTAL, 2006, 55 (05): : 676 - 690
  • [32] Reassessment of glucose effectiveness and insulin sensitivity from minimal model analysis - A theoretical evaluation of the single-compartment glucose distribution assumption
    Ni, TC
    Ader, M
    Bergman, RN
    DIABETES, 1997, 46 (11) : 1813 - 1821
  • [33] Measurement of insulin sensitivity in pregnancy with glucose clamps and the minimal model
    Buchanan, TA
    MINIMAL MODEL APPROACH AND DETERMINANTS OF GLUCOSE TOLERANCE, 1997, 7 : 323 - 343
  • [34] Validation of the oral glucose minimal model insulin sensitivity index
    Man, CD
    Caumo, A
    Basu, R
    Rizza, R
    Toffolo, G
    Cobelli, C
    DIABETES, 2003, 52 : A298 - A298
  • [35] Glucose effectiveness, insulin sensitivity, insulin secretion and endogenous glucose production of master athletes estimated by 2-comparment labeled minimal model
    Nishida, Y
    Kiyonaga, A
    Tanaka, H
    Shindo, M
    Nagasaka, S
    Kusaka, I
    Nakamura, T
    Ishikawa, S
    Saito, T
    Tajima, O
    Tokuyama, K
    DIABETES, 2000, 49 : A300 - A300
  • [36] The intravenous prandial glucose tolerance test (IVPGTT) minimal model for measuring glucose effectiveness and insulin sensitivity.
    Simeoni, M
    Basu, A
    Caumo, A
    Rizza, A
    Cobelli, C
    DIABETOLOGIA, 1999, 42 : A186 - A186
  • [37] REPRODUCIBILITY OF INSULIN SENSITIVITY MEASURED BY THE MINIMAL MODEL METHOD
    FERRARI, P
    ALLEMAN, Y
    SHAW, S
    RIESEN, W
    WEIDMANN, P
    DIABETOLOGIA, 1991, 34 (07) : 527 - 530
  • [38] Glucose effectiveness and insulin sensitivity measurements derived from the non-insulin-assisted minimal model and the clamp techniques are concordant
    Henriksen, Jan Erik
    Alford, Frank
    Ward, Glenn
    Thye-Ronn, Peter
    Levin, Klaus
    Hother-Nielsen, Ole
    Rantzau, Christian
    Boston, Ray
    Beck-Nielsen, Henning
    DIABETES-METABOLISM RESEARCH AND REVIEWS, 2010, 26 (07) : 569 - 578
  • [39] THE MODIFIED MINIMAL MODEL - APPLICATION TO MEASUREMENT OF INSULIN SENSITIVITY IN CHILDREN
    CUTFIELD, WS
    BERGMAN, RN
    MENON, RK
    SPERLING, MA
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1990, 70 (06): : 1644 - 1650
  • [40] Population approaches to estimate minimal model indexes of insulin sensitivity and glucose effectiveness using full and reduced sampling schedules
    Krudys, Kevin M.
    Kahn, Steven E.
    Vicini, Paolo
    AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2006, 291 (04): : E716 - E723