Real-time, three-dimensional echocardiography: Feasibility of dynamic right ventricular volume measurement with saline contrast

被引:50
|
作者
Ota, T [1 ]
Fleishman, CE [1 ]
Strub, M [1 ]
Stetten, G [1 ]
Ohazama, CJ [1 ]
von Ramm, OT [1 ]
Kisslo, J [1 ]
机构
[1] Duke Univ, Med Ctr, Ctr Emerging Cardiovasc Technol, Div Med & Biomed Engn, Durham, NC 27710 USA
关键词
D O I
10.1016/S0002-8703(99)70422-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background:The asymmetry and complex shape of the right ventricle have made:it difficult to determine right ventricular (RV) volume with 2-dimensional echocardiography. Three-dimensional cardiac imaging improves visualization of cardiac anatomy but is also complex and time consuming. A newly developed volumetric scanning system holds promise of obviating past limitations. Methods Real-time, transthoracic 3-dimensional echocardiographic images of the right ventricle were obtained with a high-speed volumetric ultrasound system that uses a 16:1 parallel processing schema From a 2.5 MHz matrix phased-array scanner to interrogate an entire pyramidal volume in real time. The instrumentation was used to measure RV volume in 8 excised canine hearts; dynamic real-time 3-dimensional images were also obtained from 14 normal subjects. Results Three-dimensional images were obtained in vitro and in vivo during intravenous hand-agitated saline injection to determine RV volumes. The RV volumes by real-time 3-dimentional echocardiography are well correlated with those of drained in vitro (y = 1.26x -9.92, r = 0.97; P < .0001, standard error of the estimate = .3.26 mL). For human subjects, the end-diastolic and end-systolic RV volumes were calculated by tracing serial cross-sectional, inclined C scans; functional data were validated by comparing the scans with conventional 2-dimensional echocardiographic indexes of left ventricular stroke volume. Conclusions These data indicate that RV volume measurements of excised heart by real-time 3-dimensional echocardiography are accurate and that beat-to-beat RV quantitative measurement applying this imaging method is possible. The new application of real-time 3-dimensional echocardiography presents the opportunity to develop new descriptors of cardiac performance.
引用
收藏
页码:958 / 966
页数:9
相关论文
共 50 条
  • [21] Assessment of pulmonary valve and right ventricular outflow tract with real-time three-dimensional echocardiography
    Anwar, Ashraf M.
    Soliman, Osama
    van den Bosch, Annemien E.
    McGhie, Jackie S.
    Geleijnse, Marcel L.
    Ten Cate, Folkert J.
    Meijboom, Folkert J.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2007, 23 (02): : 167 - 175
  • [22] Assessment of pulmonary valve and right ventricular outflow tract with real-time three-dimensional echocardiography
    Ashraf M. Anwar
    Osama Soliman
    Annemien E. van den. Bosch
    Jackie S. McGhie
    Marcel L. Geleijnse
    Folkert J. ten. Cate
    Folkert J. Meijboom
    The International Journal of Cardiovascular Imaging, 2007, 23 : 167 - 175
  • [23] Real-time three-dimensional echocardiography in diagnosis of right ventricular pseudoaneurysm after pacemaker implantation
    Shen, XD
    Holmberg, MJ
    Sype, J
    Hunter, C
    Mooss, AN
    Mohiuddin, SM
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2006, 23 (03): : 240 - 243
  • [24] Left ventricular volume and function in cynomolgus monkeys using real-time three-dimensional echocardiography
    Tsusaki, Hideshi
    Yonamine, Haruno
    Tamai, Asako
    Shimomoto, Mutsuko
    Kuwano, Koichi
    Iwao, Hiroshi
    Nagata, Ryoichi
    Kito, Go
    JOURNAL OF MEDICAL PRIMATOLOGY, 2007, 36 (01) : 39 - 46
  • [25] Real-time three-dimensional fetal echocardiography: Initial feasibility study
    Sklansky, MS
    Nelson, T
    Strachan, M
    Pretorius, D
    JOURNAL OF ULTRASOUND IN MEDICINE, 1999, 18 (11) : 745 - 752
  • [26] Real-time three-dimensional fetal echocardiography: Initial feasibility study
    Sklansky, MS
    Nelson, TR
    Strachan, MM
    Pretorius, DH
    CIRCULATION, 1999, 100 (18) : 394 - 394
  • [27] Real-time three-dimensional fetal echocardiography: Initial feasibility study
    Division of Pediatric Cardiology, University of California, San Diego, CA, United States
    不详
    不详
    J. Ultrasound Med., 11 (745-752):
  • [28] Real-time three-dimensional myocardial contrast echocardiography: is it clinically feasible?
    Bhan, A.
    Kapetanakis, S.
    Rana, B. S.
    Ho, E.
    Wilson, K.
    Pearson, P.
    Mushemi, S.
    Deguzman, J.
    Reiken, J.
    Harden, M. D.
    Walker, N.
    Rafter, P. G.
    Monaghan, M. J.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2008, 9 (06): : 761 - 765
  • [29] Evaluation of the Right Ventricular Function in Pneumoconiosis Patients Using Volume-Time Curves Obtained by Real-Time Three-Dimensional Echocardiography
    Shi, Doufei
    Zhang, Jie
    Liu, Xinkai
    Zhang, Gang
    Cui, Lianqun
    CELL BIOCHEMISTRY AND BIOPHYSICS, 2014, 70 (03) : 1553 - 1557
  • [30] Left ventricular dysfunction during right ventricular pacing: volumetric analysis with real-time three-dimensional echocardiography
    Wolber, T.
    Brunckhorst, C.
    Duru, F.
    EUROPEAN HEART JOURNAL, 2009, 30 : 345 - 346