Pump less steady-flow microfluidic chip for cell culture

被引:30
|
作者
Marimuthu, Mohana [1 ]
Kim, Sanghyo [1 ]
机构
[1] Gachon Univ, Dept Bionanotechnol, Gyeonggi Do 461701, South Korea
关键词
Microfluidic; Bioreactor; Perfusion; Flow rate; Dermal fibroblasts; PERFUSION CULTURE; MAMMALIAN-CELLS; SYSTEM; PLATFORM; ARRAYS;
D O I
10.1016/j.ab.2013.02.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The current research engineered a pumpless energy-efficient microfluidic perfusion cell culture chip that works by modifying the basic gravity-driven siphon flow using an intravenous (IV) infusion set as a conventional, inexpensive, and sterile tool. The IV set was modified to control the constant hydrostatic head difference, thereby maintaining the steady flow rate medium perfusion. The micro-bioreactor chip demonstrated flexibility in controlling a wide range of flow rates from 0.1 to 10 ml/min, among which 1- and 5-ml/min flow rates were examined as suitable shear flows for long-term dermal fibroblast cell culture, paving the way for artificial skin development. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:161 / 163
页数:3
相关论文
共 50 条
  • [31] Stagnation pressure, the Bernoulli equation, and the steady-flow energy equation
    Vakil A.
    Green S.I.
    International Journal of Mechanical Engineering Education, 2002, 39 (02) : 130 - 138
  • [32] EFFECT OF WIND-TUNNEL NOZZLE ON STEADY-FLOW NONUNIFORMITIES
    RIBNER, HS
    TUCKER, M
    JOURNAL OF THE AERONAUTICAL SCIENCES, 1952, 19 (06): : 426 - 427
  • [33] Design and fabrication of device for cell dynamic culture in microfluidic chip
    Jiang Y.
    Liu C.
    Wei J.
    Yin S.-Q.
    Ding L.-Q.
    Li J.-M.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2019, 27 (09): : 2020 - 2027
  • [34] Microfluidic cell culture system with on-chip hypoxic conditioning
    Takano, Atsushi
    Tanaka, Masato
    Futai, Nobuyuki
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 4474 - 4477
  • [35] Pumping-induced perturbation of flow in microfluidic channels and its implications for on-chip cell culture
    Zhou, Jianhua
    Ren, Kangning
    Dai, Wen
    Zhao, Yihua
    Ryan, Declan
    Wu, Hongkai
    LAB ON A CHIP, 2011, 11 (13) : 2288 - 2294
  • [36] RELATION BETWEEN STEADY-FLOW + DYNAMIC VISCOSITY FOR POLYETHYLENE MELTS
    ONOGI, S
    OGIHARA, S
    KATO, H
    FUJII, T
    JOURNAL OF PHYSICAL CHEMISTRY, 1964, 68 (06): : 1598 - &
  • [37] EFFECTS OF OSCILLATORY SHEAR ON THE STEADY-FLOW OF SHEAR THICKENING SUSPENSIONS
    JOMHA, AI
    WOODCOCK, LV
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1990, 68 (06): : 550 - 557
  • [38] A novel method of cell culture based on the microfluidic chip for regulation of cell density
    Zhang, Fei
    Zhang, Rongbiao
    Wei, Mingji
    Zhang, Yecheng
    BIOTECHNOLOGY AND BIOENGINEERING, 2021, 118 (02) : 852 - 862
  • [39] Cell-sorting centrifugal microfluidic chip with a flow rectifier
    Ma, Junyu
    Wu, Yihui
    Liu, Yongshun
    Ji, Yuan
    Yang, Mei
    Zhu, Hongquan
    LAB ON A CHIP, 2021, 21 (11) : 2129 - 2141
  • [40] Microfluidic cell sorting chip and its flow field simulation
    Yang, Jing
    Yang, Jun
    Xu, Rong
    Cao, Yi
    Hu, Ning
    Zheng, Xiaolin
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2009, 30 (07): : 1508 - 1511