Current knowledge on EVAR with the ultra-low profile Ovation Abdominal Stent-Graft System

被引:0
|
作者
Moulakakis, K. G. [1 ]
Dalainas, I. [1 ]
Kakisis, J. [1 ]
Giannakopoulos, T. G. [1 ]
Liapis, C. D. [1 ]
机构
[1] Univ Athens, Sch Med, Dept Vasc Surg, GR-10679 Athens, Greece
来源
JOURNAL OF CARDIOVASCULAR SURGERY | 2012年 / 53卷 / 04期
关键词
Endovascular procedures; Aneurysm; Aortic aneurysm; abdominal; ENDOVASCULAR REPAIR; AORTIC-ANEURYSM; COLLAPSE; OUTCOMES; TRIAL;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Endovascular aneurysm repair (EVAR) has revolutionized the treatment of infrarenal abdominal aortic aneurysms (AAAs). The continuous collaboration of surgeons and bioengineers in the improvement of the devices the last two decades, lead to a continuous redesigning and improvement of the various endografts. In the last few years, the majority of companies have developed renewed models of grafts and have modified delivery systems tending to lower profile in order to deal with difficult anatomies. The ultra low profile 14F OD Ovation (Trivascular) Abdominal Stent-graft System with innovative sealing technology achieved through inflatable sealing rings, allows treatment of AAAs with small in diameter access vessels that might be unsuitable for EVAR with other currently available stent-grafts. The aim of the present paper was to analyze the technical characteristics and properties of this endograft and to review the current literature.
引用
收藏
页码:427 / 432
页数:6
相关论文
共 50 条
  • [21] Outcomes of EVAR with the endurant stent-graft system in patients with infrarenal ruptured abdominal aortic aneurysms: Is hostile anatomy a challenging factor?
    Kucukay, Fahrettin
    Karan, Adnan
    Simsek, Erdal
    Ozdemir, Mustafa
    Okten, Sarper
    Ulus, Ahmet Tulga
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (11) : 2210 - 2217
  • [22] Graft Inflow Stenosis Induced by the Inflatable Ring Fixation Mechanism the Ovation Stent-Graft System: Hemodynamic and Clinical Implications
    Ioannou, Christos V.
    Kontopodis, Nikolaos
    Metaxa, Eleni
    Papaharilaou, Yannis
    Georgakarakos, Efstratios
    Kafetzakis, Alexandros
    Kehagias, Elias
    Tsetis, Dimitrios
    JOURNAL OF ENDOVASCULAR THERAPY, 2014, 21 (06) : 829 - 838
  • [23] Initial Single-Center Experience with the Ovation Stent-Graft System in the Treatment of Abdominal Aortic Aneurysms: Application to Challenging Iliac Access Anatomies
    Trellopoulos, George
    Georgakarakos, Efstratios
    Pelekas, Dimitrios
    Papachristodoulou, Athanasia
    Kalaitzi, Anastasia
    Asteri, Theodora
    ANNALS OF VASCULAR SURGERY, 2015, 29 (05) : 913 - 919
  • [24] The Effect of Ovation Stent-Graft System on Aortic Pulse Wave Velocity: Preliminary Report on 3 Cases
    Georgakarakos, Efstratios
    Argyriou, Christos
    Ioannou, Christos V.
    Kontopodis, Nikolaos
    Lazarides, Miltos K.
    ANNALS OF VASCULAR SURGERY, 2015, 29 (08) : 1658.e5 - 1658.e9
  • [25] Ultra-low profile polymer-filled stent graft for abdominal aortic aneurysm treatment: a two-year follow-up
    Ierardi, Anna Maria
    Tsetis, Dimitrios
    Ioannou, Christos
    Lagana, Domenico
    Floridi, Chiara
    Petrillo, Mario
    Pinto, Antonio
    Piffaretti, Gabriele
    Carrafiello, Gianpaolo
    RADIOLOGIA MEDICA, 2015, 120 (06): : 542 - 548
  • [26] Ultra-low profile polymer-filled stent graft for abdominal aortic aneurysm treatment: a two-year follow-up
    Anna Maria Ierardi
    Dimitrios Tsetis
    Christos Ioannou
    Domenico Laganà
    Chiara Floridi
    Mario Petrillo
    Antonio Pinto
    Gabriele Piffaretti
    Gianpaolo Carrafiello
    La radiologia medica, 2015, 120 : 542 - 548
  • [27] Incidence and Outcomes of Anaphylactic Reaction Related to Polymer Leak With the Ovation Abdominal Stent Graft System
    Gupta, Nav Yash
    Mahrouyan, Omeed
    Briggs, Charles
    Hynes, Karen
    Azizzadeh, Ali
    JOURNAL OF VASCULAR SURGERY, 2018, 67 (06) : E187 - E187
  • [28] Current status of open versus endovascular stent-graft repair of abdominal aortic aneurysm
    Rutherford, RB
    Krupski, WC
    JOURNAL OF VASCULAR SURGERY, 2004, 39 (05) : 1129 - 1139
  • [29] Percutaneous placement of a low-profile stent-graft device for aortic dissections
    Quinn, SF
    Duke, DJ
    Baldwin, SS
    Bascom, TH
    Ruff, SJ
    Swangard, RJ
    DeHaas, DR
    Padgett, RC
    Bergin, PJ
    Lau, S
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (08) : 791 - 798
  • [30] Abdominal aortic aneurysm treatment: Preliminary results with the talent stent-graft system
    Uflacker, R
    Robison, JG
    Brothers, TE
    Pereira, AH
    Sanvitto, PC
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (01) : 51 - 60