Research on Direct Calibration of Electromagnetic Flowmeter in Partially Filled Pipes

被引:1
|
作者
Yin, Shiyi [1 ]
Li, Bin [1 ]
机构
[1] Shanghai Univ, Sch Mechatron Engn & Automat, Shanghai 200072, Peoples R China
关键词
Direct Calibration; Electromagnetic Flowmeter; Partially Filled Pipe; Piecewise Interpolation;
D O I
10.4028/www.scientific.net/AMR.712-715.1904
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The methodology of the direct calibration for the electromagnetic flowmeter in partially filled pipes is presented in this paper. Based on the principle of the electromagnetic flowmeter, two main respects, including the flow liquid level and the weight function in partially filled pipes are introduced briefly, and the calibration technologies of the sensor, which consist of the device arrangements, the accurate measurement of the liquid level and the calibration of the flow discharge, are emphasized on, with the methodology based on the piecewise interpolation employed. The experimental results demonstrate that the methodology of the direct calibration is simple and effective for the real flow calibration of the electromagnetic flowmeter in partially filled pipes, with the stable measurement and the accuracy requirement satisfied.
引用
收藏
页码:1904 / 1909
页数:6
相关论文
共 50 条
  • [1] The Design of Electromagnetic Flowmeter in Partially Filled Pipes
    Wei Kaixia
    Haoshurong
    MECHANICAL AND ELECTRONICS ENGINEERING III, PTS 1-5, 2012, 130-134 : 1357 - +
  • [2] Technical Implementation of Electromagnetic Flowmeter in Partially Filled Pipes
    Wei Kaixia
    Hao Guoshen
    Zhu Xinchen
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION & INSTRUMENTATION, VOLS 1 - 4, 2010, : 144 - 148
  • [3] Study on Electromagnetic Flowmeter for Partially Filled Flow Measurement
    Yao, Jun
    Wang, WeiGuo
    Shi, Ji
    2011 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-6, 2011, : 3568 - 3573
  • [4] Electromagnetic flow measurement in partially filled pipes
    Daney, B
    WATER-ENGINEERING & MANAGEMENT, 1999, 146 (11): : 32 - 34
  • [5] The virtual current of an electromagnetic flow meter in partially filled pipes
    Zhang, XZ
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (11) : 1852 - 1855
  • [6] CALIBRATION TECHNIQUES FOR ELECTROMAGNETIC FLOWMETER
    MAKIN, GS
    BERGEL, DH
    WELBOURN, RB
    BRITISH JOURNAL OF SURGERY, 1968, 55 (01) : 74 - &
  • [7] THE EFFECT OF CONDUCTING PIPES ON ELECTROMAGNETIC FLOWMETER SENSITIVITY
    HEMP, J
    VERSTEEG, HK
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1988, 21 (07) : 1091 - 1098
  • [8] Electromagnetic flowmeter used as calibration standard
    Pollution Equipment News, 2000, 33 (04):
  • [9] A TRANSIENT ELECTROMAGNETIC FLOWMETER AND CALIBRATION FACILITY
    LEFEBVRE, PJ
    DURGIN, WW
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1990, 112 (01): : 12 - 15
  • [10] Solving weight function for the partially filled pipe electromagnetic flowmeter by means of finite element numerical analysis
    Wei, Kaixia
    Gu, Shulong
    He, Longqing
    ADVANCES IN CHEMICAL ENGINEERING II, PTS 1-4, 2012, 550-553 : 3395 - 3399