Anion exchangers with negatively charged functionalities in hyperbranched ion-exchange layers for ion chromatography

被引:24
|
作者
Uzhel, Anna S. [1 ]
Zatirakha, Alexandra V. [1 ]
Smirnov, Konstantin N. [1 ]
Smolenkov, Alexandr D. [1 ]
Shpigun, Oleg A. [1 ]
机构
[1] Lomonosov Moscow State Univ, Dept Chem, Leninskie Gory 1-3,GSP 1, Moscow 119991, Russia
关键词
Ion chromatography; Poly(styrene-divinylbenzene); Covalently-bonded anion exchanger; Hyperbranched functional layer; Negatively charged functionalities; Determination of anions; WALLED CARBON NANOTUBES; STATIONARY PHASES; MODIFIED SILICA; PERFORMANCE; COLUMNS; IONENES;
D O I
10.1016/j.chroma.2016.12.066
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Novel pellicular poly(styrene-divinylbenzene)-based (PS-DVB) anion exchangers with covalently-bonded hyperbranched functional ion-exchange layers containing negatively charged functionalities are obtained and examined. The hyperbranched coating is created on the surface of aminated PS-DVB substrate by repeating the modification cycles including alkylation with 1,4-butanediol diglycidyl ether (1,4-BDDGE), and amination of the terminal epoxide rings with methylamine (MA) or glycine (Gly). The influence of the position and the number of the layers with glycine, as well as of the total number of the layers of amine in the coating on the chromatographic properties of the obtained stationary phases is investigated. Chromatographic performance of the obtained stationary phases is evaluated using the model mixtures of inorganic and organic anions with hydroxide eluent. It is shown that the best selectivity toward weakly retained organic acids and oxyhalides is possessed by the anion exchanger obtained after 5 modification cycles, with glycine being used in the first one. Such anion exchanger packed in 25-cm long column is capable of separating 22 anions in 58 min including 7 standard anions, mono-, di- and trivalent organic acids, oxyhalides, and some other double- and triple-charged anions. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:57 / 64
页数:8
相关论文
共 50 条
  • [11] THE OSMOTIC APPROACH TO ION-EXCHANGE EQUILIBRIUM .1. ANION EXCHANGERS
    SOLDANO, B
    CHESNUT, D
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1955, 77 (05) : 1334 - 1339
  • [12] HIGH-PERFORMANCE ION-EXCHANGE CHROMATOGRAPHY OF PROTEINS ON NONPOROUS ION-EXCHANGERS
    KATO, Y
    KITAMURA, T
    MITSUI, A
    HASHIMOTO, T
    JOURNAL OF CHROMATOGRAPHY, 1987, 398 : 327 - 334
  • [13] ION-EXCHANGE CHROMATOGRAPHY
    ROSSOMANDO, EF
    METHODS IN ENZYMOLOGY, 1990, 182 : 309 - 317
  • [14] ION-EXCHANGE CHROMATOGRAPHY
    SAMUELSO.O
    ANALYTICA CHIMICA ACTA, 1967, 38 (1-2) : 163 - +
  • [15] ION-EXCHANGE CHROMATOGRAPHY
    Jungbauer, Alois
    Hahn, Rainer
    GUIDE TO PROTEIN PURIFICATION, SECOND EDITION, 2009, 463 : 349 - 371
  • [16] CHROMATOGRAPHY AND ION-EXCHANGE
    不详
    NATURE, 1949, 163 (4137) : 235 - 237
  • [17] KINETICS OF ION-EXCHANGE OF A NEGATIVELY CHARGED CHLORIDE COMPLEX OF BISMUTH(III)
    ZAKI, AB
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1980, 19 (08): : 798 - 800
  • [18] Polyelectrolyte-grafted anion exchangers with hydrophilic intermediate layers for ion chromatography
    Zhang, Kai
    Zhao, Yonggang
    Ye, Mingli
    Lou, Chaoyan
    Zhu, Yan
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1682
  • [19] Influence of the ion-exchange functional groups on protein anion-exchange chromatography
    Li, Tingyu
    Vanderah, David
    ANALYTICAL BIOCHEMISTRY, 2025, 702
  • [20] ION CHROMATOGRAPHY WITH AN ION-EXCHANGE MEMBRANE SUPPRESSOR
    HANAOKA, Y
    MURAYAMA, T
    MURAMOTO, S
    MATSUURA, T
    NANBA, A
    JOURNAL OF CHROMATOGRAPHY, 1982, 239 (APR): : 537 - 548