Assessment and assurance of quality in water measurement by coulometric Karl Fischer titration of petroleum products

被引:22
|
作者
Ivanova, PG
Aneva, ZV [1 ]
机构
[1] Univ Prof Dr Assen Zlatarov, Analyt Dept, Burgas 8010, Bulgaria
[2] LUKOIL, NEFTOCHIM, BOURGAS, JSC,Res & Dev Lab,Analyt Dept, Burgas 8104, Bulgaria
关键词
water determination; coulometric Karl Fischer titration; petroleum products;
D O I
10.1007/s00769-005-0056-x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The precise and accurate determination of water in petroleum products-gasoline, diesel oil and aromatic hydrocarbons-is of significant importance for their normal functional and operational characteristics for economics as well as in meeting international requirements. The standard method ISO 12937 for the measurement of water by the coulometric Karl Fischer titration method was subject to within-laboratory assessment. Thereby it was established that the analytical procedure could not always be relied upon, especially when low levels of water were determined. The aim of this work is to assess each stage of the test procedure depending on the particular problems defined by the samples, using high-reactive Karl Fischer reagents and coulometric cells with and without a diaphragm, and to indicate the major factors causing the uncertainty. A reduced combined uncertainty was achieved by modifying the sample preparation step, the administration of the moisture in the coulometric cell, and sample injection manipulation. Experiments showed that the cell without the diaphragm ensures lower and uniform uncertainty of the measurements in the range of 0.01 to 10 mg H2O in comparison to the cell with a diaphragm and therefore is more appropriate for the determination of low water levels in the petroleum products. A procedure that utilized a mixture of the reagent and toluene (10:6) was able to resolve the problem of two phases of formation and reduced conductivity of the reagent in direct titration of diesel oils. The results suggest that the modified procedure ensures relative expanded uncertainty equal to or less than 2.0% (n=5, confidence interval close to 95%) and 99.4% recovery for petroleum products investigated in repeatability conditions.
引用
收藏
页码:543 / 549
页数:7
相关论文
共 50 条
  • [1] Assessment and assurance of quality in water measurement by coulometric Karl Fischer titration of petroleum products
    Pavlina G. Ivanova
    Zara V. Aneva
    Accreditation and Quality Assurance, 2006, 10 : 543 - 549
  • [2] Coulometric Karl Fischer titration simplifies water content testing
    Poynter, Wesley G.
    Barrlos, Roy J.
    Oil and Gas Journal, 1994, 92 (15): : 53 - 56
  • [3] Interlaboratory assessment of measurement precision and bias in the coulometric Karl Fischer determination of water
    Margolis, SA
    Angelo, JB
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (03) : 505 - 512
  • [4] Interlaboratory assessment of measurement precision and bias in the coulometric Karl Fischer determination of water
    Sam A. Margolis
    Jacob B. Angelo
    Analytical and Bioanalytical Chemistry, 2002, 374 : 505 - 512
  • [5] COULOMETRIC KARL FISCHER TITRATION SIMPLIFIES WATER-CONTENT TESTING
    POYNTER, WG
    BARRIOS, RJ
    OIL & GAS JOURNAL, 1994, 92 (15) : 53 - 54
  • [6] A STUDY OF THE CATHODE REACTION IN KARL FISCHER COULOMETRIC TITRATION
    KATOH, H
    FUJIMOTO, Y
    KUWATA, S
    ANALYTICAL SCIENCES, 1991, 7 (02) : 299 - 302
  • [7] Water content determination in biodiesel: Optimization of methodology in coulometric karl fischer titration
    Vicentim M.P.
    Barreto Sousa M.V.
    Fernandes Da Silva V.
    Lionel Mateus V.
    Rodrigues J.M.
    Smargaro Da Cunha V.
    Journal of ASTM International, 2010, 7 (02):
  • [8] Determination of the water content of amphiphilic liquid crystals by coulometric Karl Fischer titration
    Dunkel, R.
    Hahn, M.
    Borisch, K.
    Neumann, B.
    Liquid Crystals, 24 (02):
  • [9] Determination of moisture in biomass by coulometric Karl Fischer titration
    Jedrychowska, Sylwia
    Kowalczyk, Anna
    NAFTA-GAZ, 2022, (05): : 393 - 400
  • [10] Karl Fischer coulometric titration using a diaphragmless cell
    Katoh, H
    Katayama, N
    Kaneko, T
    BUNSEKI KAGAKU, 1999, 48 (07) : 711 - 715