Evaluation of liver fat in the presence of iron with MRI using T2*correction: a clinical approach

被引:20
|
作者
Benjamin, Henninger [1 ]
Christian, Kremser [1 ]
Stefan, Rauch [1 ]
Robert, Eder [1 ]
Werner, Judmaier [1 ]
Heinz, Zoller [2 ]
Henrik, Michaely [3 ]
Michael, Schocke [1 ]
机构
[1] Med Univ Innsbruck, Dept Radiol, A-6020 Innsbruck, Austria
[2] Med Univ Innsbruck, Dept Internal Med, A-6020 Innsbruck, Austria
[3] Heidelberg Univ, Med Fac Mannheim, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, Mannheim, Germany
关键词
MRI; Liver; Steatosis hepatitis; Iron overload; T2*; MAGNETIC-RESONANCE-SPECTROSCOPY; HEPATIC IRON; NONALCOHOLIC STEATOHEPATITIS; SAMPLING VARIABILITY; NEEDLE-BIOPSY; GRADIENT-ECHO; QUANTIFICATION; STEATOSIS; DIAGNOSIS; ACCURACY;
D O I
10.1007/s00330-012-2745-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess magnetic resonance imaging (MRI) with conventional chemical shift-based sequences with and without T2* correction for the evaluation of steatosis hepatitis (SH) in the presence of iron. Thirty-one patients who underwent MRI and liver biopsy because of clinically suspected diffuse liver disease were retrospectively analysed. The signal intensity (SI) was calculated in co-localised regions of interest (ROIs) using conventional spoiled gradient-echo T1 FLASH in-phase and opposed-phase (IP/OP). T2* relaxation time was recorded in a fat-saturated multi-echo-gradient-echo sequence. The fat fraction (FF) was calculated with non-corrected and T2*-corrected SIs. Results were correlated with liver biopsy. There was significant difference (P < 0.001) between uncorrected and T2* corrected FF in patients with SH and concomitant hepatic iron overload (HIO). Using 5 % as a threshold resulted in eight false negative results with uncorrected FF whereas T2* corrected FF lead to true positive results in 5/8 patients. ROC analysis calculated three threshold values (8.97 %, 5.3 % and 3.92 %) for T2* corrected FF with accuracy 84 %, sensitivity 83-91 % and specificity 63-88 %. FF with T2* correction is accurate for the diagnosis of hepatic fat in the presence of HIO. Findings of our study suggest the use of IP/OP imaging in combination with T2* correction. aEuro cent Magnetic resonance helps quantify both iron and fat content within the liver aEuro cent T2* correction helps to predict the correct diagnosis of steatosis hepatitis aEuro cent "Fat fraction" from T2*-corrected chemical shift-based sequences accurately quantifies hepatic fat aEuro cent "Fat fraction" without T2* correction underestimates hepatic fat with iron overload.
引用
收藏
页码:1643 / 1649
页数:7
相关论文
共 50 条
  • [11] Fat Content Effect in the Measurement of T2* for Iron Quantification in the Liver in Patients With Suspected Myocardial Iron Overload
    Flavia P Junqueira
    Juliano L Fernandes
    Gustavo A Pinto
    Sandra R Loggetto
    Maria Cristina Purini
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [12] Cardiac iron evaluation by T2*MRI in transfusion dependent patients with acquired anemias
    Angelucci, E.
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2007, 92 : 17 - 17
  • [13] Evaluation of cardiac iron overload by cardiac MRI T2 in regularly transfused MDS
    Pascal, L.
    Rose, C.
    Fenaux, P.
    Ernst, O.
    Chiavassa, H.
    Beyne-Rauzy, O.
    Brechignac, S.
    Balkaran, S.
    Senechal, Q.
    LEUKEMIA RESEARCH, 2009, 33 : S109 - S109
  • [14] Can we measure iron overload in the heart using in vivo MRI T2*?
    Taigang He
    John-Paul Carpenter
    Sutipong Jongjirasiri
    Jiraporn Laothamatas
    Suthat Fucharoen
    David Firmin
    Dudley Pennell
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [15] Single ROI Versus Multislice T2*MRI Approach for the Quantification of Hepatic Iron Overload
    Meloni, Antonella
    Luciani, Antongiulio
    Positano, Vincenzo
    De Marchi, Daniele
    Valeri, Gianluca
    Restaino, Gennaro
    Roccamo, Gaetano
    Armari, Sabrina
    Dell'Amico, Maria Chiara
    Favilli, Brunella
    Lippi, Alma
    Lombardi, Massimo
    Pepe, Alessia
    BLOOD, 2010, 116 (21) : 1730 - 1730
  • [16] Cardiac and pancreatic iron overload evaluation of sickle/β-Thalassemia patients utilizing T2* MRI
    Orly Goitein
    Eli Konen
    Husam Ghoti
    Ariel Koren
    Carina Levine
    Alain Berebi
    Pinhas Stark
    Eliezer Rachmilewitz
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [17] Evaluation of T2*MRI in accessing hepatic steatosis
    Zhang, Qian
    Zhang, Chunyu
    Zhang, Yonggui
    Qi, Wenqian
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2013, 28 : 897 - 897
  • [18] Reassessing the value of MRI T2* in evaluation of hepatic and myocardial iron concentration: An institutional study
    Fahmy, Hadeer Safwat
    Khater, Nivan Hany
    El Shahat, Hazem Mohamed
    Madani, Ahmed Abdelsatar
    El Hadidy, Samah Saleh
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2015, 46 (04): : 1085 - 1090
  • [19] T1, T2, and Fat Fraction Cardiac MR Fingerprinting: Preliminary Clinical Evaluation
    Jaubert, Olivier
    Cruz, Gastao
    Bustin, Aurelien
    Hajhosseiny, Reza
    Nazir, Sohaib
    Schneider, Torben
    Koken, Peter
    Doneva, Mariya
    Rueckert, Daniel
    Masci, Pier-Giorgio
    Botnar, Rene M.
    Prieto, Claudia
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (04) : 1253 - 1265
  • [20] Iron Overload in Patients With Heavily Transfused Sickle Cell Disease-Correlation of Serum Ferritin With Cardiac T2*MRI (CMRTools), Liver T2*MRI, and R2-MRI (Ferriscan®)
    Alkindi, Salam
    Panjwani, Vinodh
    Al-Rahbi, Sarah
    Al-Saidi, Khalid
    Pathare, Anil, V
    FRONTIERS IN MEDICINE, 2021, 8