Magnetic resonance imaging of intraoral hard and soft tissues using an intraoral coil and FLASH sequences

被引:43
|
作者
Fluegge, Tabea [1 ]
Hoevener, Jan-Bernd [2 ]
Ludwig, Ute [2 ]
Eisenbeiss, Anne-Kathrin [1 ]
Spittau, Bjoern [3 ]
Hennig, Juergen [2 ]
Schmelzeisen, Rainer [1 ]
Nelson, Katja [1 ]
机构
[1] Univ Med Ctr Freiburg, Dept Oral & Maxillofacial Surg, Hugstetter Str 55, D-79106 Freiburg, Germany
[2] Univ Med Ctr Freiburg, Dept Radiol, Med Phys, Breisacher Str 60, D-79106 Freiburg, Germany
[3] Albert Ludwig Univ Freiburg, Inst Anat & Cell Biol, Albertstr 17, D-79104 Freiburg, Germany
关键词
Magnetic resonance imaging; Cone beam computed tomography; Dimensional measurement; Accuracy; Dental Implantation; COMPUTED-TOMOGRAPHY; DENTAL MRI; TEETH; ACCURACY; SURGERY; CT;
D O I
10.1007/s00330-016-4254-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To ascertain the feasibility of MRI as a non-ionizing protocol for routine dentomaxillofacial diagnostic imaging. Wireless coils were used for MRI of intraoral hard and soft tissues. FLASH MRI was applied in vivo with a mandible voxel size of 250 x 250 x 500 mu m(3), FOV of 64 x 64 x 28 mm(3) and acquisition time of 3:57 min and with a maxilla voxel size of 350 mu m(3) and FOV of 34 cm(3) in 6:40 min. Ex vivo imaging was performed in 4:38 min, with a resolution of 200 mu m(3) and FOV of 36.5 cm(3). Cone beam (CB) CT of the mandible and subjects were acquired. MRI was compared to CBCT and histological sections. Deviations were calculated with intraclass correlation coefficient (ICC) and coefficient of variation (c(v)). A high congruence between CBCT, MRI and specimens was demonstrated. Hard and soft tissues including dental pulp, periodontium, gingiva, cancellous bone and mandibular canal contents were adequately displayed with MRI. Imaging of select intraoral tissues was achieved using custom MRI protocols with an easily applicable intraoral coil in a clinically acceptable acquisition time. Comparison with CBCT and histological sections helped demonstrate dimensional accuracy of the MR images. The course of the mandibular canal was accurately displayed with CBCT and MRI. aEuro cent MRI is a clinically available diagnostic tool in dentistry aEuro cent Intraoral hard and soft tissues can be imaged with a high resolution with MRI aEuro cent The dimensional accuracy of MRI is comparable to cone beam CT.
引用
收藏
页码:4616 / 4623
页数:8
相关论文
共 50 条
  • [21] MEASURING COOLING IN SOFT TISSUES USING MAGNETIC RESONANCE THERMOGRAPHY
    Sajjadi, Amir
    Manstein, Dieter
    Carp, Stefan
    LASERS IN SURGERY AND MEDICINE, 2015, 47 : 11 - 12
  • [22] Surface Coil for Magnetic Resonance Imaging
    Ricardo Ferro, Beatriz Taimy
    Ramirez Aguilera, Andres
    Alvarez Guerra, Eloy Daniel
    REVISTA CUBANA DE INGENIERIA, 2015, 6 (01): : 13 - 21
  • [23] In Vivo MRI-Based Dental Impression Using an Intraoral RF Receiver Coil
    Tymofiyeva, O.
    Rottner, K.
    Gareis, D.
    Boldt, J.
    Schmid, F.
    Lopez, M. A.
    Richter, E-J.
    Jakob, P. M.
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2008, 33B (04) : 244 - 251
  • [24] Strain elastography of palatal tumors in conjunction with intraoral ultrasonography, computed tomography, and magnetic resonance imaging: 2 case reports
    Ogura, Ichiro
    Toshima, Hiroo
    Akashiba, Tohru
    Ono, Junya
    Okada, Yasuo
    IMAGING SCIENCE IN DENTISTRY, 2020, 50 (01) : 73 - 79
  • [25] Effects of Local Anesthetics on Tissue Penetration Using Diode Lasers in Intraoral Tissues
    Romanos, Georgios
    Wu, Jamie
    Roibu, Ed Gheorghe
    Zhang, Yun
    Delgado-Ruiz, Rafael
    PHOTOBIOMODULATION PHOTOMEDICINE AND LASER SURGERY, 2024, 42 (09) : 598 - 603
  • [26] SURFACE COIL FLASH MAGNETIC-RESONANCE-IMAGING OF THE FASTING AND SECRETIN-STIMULATED PANCREAS
    BIS, KG
    JACOBS, IG
    ZINGAS, AP
    KLEIN, MA
    KLING, GA
    INVESTIGATIVE RADIOLOGY, 1990, 25 (09) : 977 - 982
  • [27] Magnetic Resonance Imaging Assessment of Subchondral Bone and Soft Tissues in Knee Osteoarthritis
    Crema, Michel D.
    Roemer, FrankW.
    Marra, Monica D.
    Guermazi, Ali
    RHEUMATIC DISEASE CLINICS OF NORTH AMERICA, 2009, 35 (03) : 557 - +
  • [28] New approach to improve the keratinised peri-implant soft tissues in patients with intraoral osteocutaneous reconstruction using a free flap
    Patel, N.
    Patel, D.
    Kwok, J.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2017, 55 (07): : 732 - 733
  • [29] Accuracy of Intraoral Digital Impressions for Whole Upper Jaws, Including Full Dentitions and Palatal Soft Tissues
    Gan, Ning
    Xiong, Yaoyang
    Jiao, Ting
    PLOS ONE, 2016, 11 (07):
  • [30] MAGNETIC-RESONANCE IMAGING OF THE ORBITS USING A BINOCULAR SURFACE COIL
    DEANS, HE
    REDPATH, TW
    SMITH, FW
    PAREKH, S
    FORRESTER, JV
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (728): : 665 - 672